1.The upregulation mechanism of OCT4 signaling by ID1 in colorectal cancer
Shuang SHANG ; Jia-wei SONG ; Fang HUA
Acta Pharmaceutica Sinica 2021;56(7):1945-1952
Inhibitor of DNA binding 1 (ID1) has an aberrantly high expression in multiple cancer tissues, including colon cancer, lung cancer, breast cancer, and so on, which is closely related to cancer aggressiveness and poor clinical outcomes in cancer patients. It has been reported that ID1 maintains colorectal cancer cells (CRCs) stemness traits and contributes to the CRC drug resistance. While, the biological molecular mechanisms have not been fully elucidated. In this research, we found that ID1 upregulates octamer binding transcription factor (OCT4) protein level as well as OCT4 signaling pathway
2.Full-time doctor of medicine in China: current status,problems and solutions from special assessment perspective
Jinzhong JIA ; Wei CAO ; Hong SONG ; Liping DUAN
Chinese Journal of Medical Science Research Management 2017;30(4):300-304
Objective To analyze the problems of doctor of medicine in China,and to explore the efforts to improvethe training quality of doctor of medicine.Methods The paper selected 5medical colleges which participated the thematic evaluation of doctor of medicinedegreeauthorization centers in 2014,then analyzed the relevant data of doctor of medicine during 2011-2015,such as education condition,enrollment scale,training objective,curriculum setting,scientific research trainingand clinical practice by descriptive study.Results The average of affiliated hospitals is 6.0.The number of medical doctor entrance exam increased by 1.5 times during 2011-2015.The training institutions set up clear training objective of applied talents.A three-stage cultivation mode of course learning,clinical practice and scientific research training is widespread enforcement.However,the subject and basiccondition varies in different schools.The teachers’ professional level is uneven.The quality of candidates needsto be improved.Curriculum design is lack of pertinence.Standardization of clinical practice andscientiFlc training system is not enoughat the same time.Conclusions The suggestions to promote the reform of full-time doctor of medicineare:improving the subject building;increasethe number of students enrollment appropriately;strengthening pertinence of curriculum system;perfecting quality evaluating system;exploring the training mode called “5 + 3 + X”.
3.Application of Stream-media Transmission Technology in PACS and Distance Diagnosis
Wei SONG ; Jia-Xue QI ; Xiao-Hui OUYANG ;
Chinese Medical Equipment Journal 2004;0(09):-
Objective To propose a stream-media technology based on the new transmission technology. Methods Firstly,we explored the advantages and disadvantages of exiting PACS image in LAN (Local Area Network) and WAN (Wide Area Network) and then expounded distance diagnosis related to HIS and PACS,VPN technology,wireless network applications,more points consultation applied technology. At last,we made an analysis of the characteristics of the stream-media transmission technology. Results The characteristics of low bandwidth occupied,high security,and high scalability of stream-media transmission technology fit the needs of PACS development. Conclusion Application of streammedia technology transferred in PACS image provides a new economical and practical technical solution to break through limitation of network bandwidth in medical imaging integrated information,and to thoroughly make use of medical resource.
4.Research on compensatory of contralateral vertebral artery by MRA in unilateral stenosis
Wei HAN ; Peisong SONG ; Weili QI ; Kangmei KONG ; Jia OUYANG
Chinese Journal of Postgraduates of Medicine 2006;0(05):-
Objective To evaluate the MRA by measuring the diameter of the stenosis artery and the contralateral normal vertebral artery with unilateral stenosis. Methods Seventeen-six patients were divided into normal group and vertebral arterial type of cervical spondylosis group.Among 26 vertebral arterial type of cervical spondylosis cases,13 cases appeared as vertebral arterial type with unilateral stenosis of ≤1.6 mm in diameter .Statistics assessment of MRA in stenosis and contralateral artery was engaged. Results The unilateral artery stenosis diameter measured
5.Association between polymorphism of acetaldehyde dehydrogenase 2 gene and H-type hypertension in the elderly
Yunping JIA ; Song HU ; Hua WEI ; Nina AN ; Yongjun MAO
Chinese Journal of Geriatrics 2015;34(3):234-237
Objective To explore the association between the polymorphism rs671 site of the acetaldehyde dehydrogenase 2 (ALDH2) gene and H-type hypertension in the elderly in Han nationality in Qingdao.Methods Totally 406 patients aged 60-90 years with primary hypertension were randomly selected in the study.Serum levels of homocysteine(Hcy),folate and vitamin B12 were determined and all patients were divided into H-type hypertension group and non H-type hypertension group.Gene chip technology was used to analyze the ALDH2 (rs671) polymorphism,and the association between ALDH2 gene and H type hypertension was evaluated.Results Of all hypertensive participants,82.0% (333/406) were in H-type hypertension,87.4% (221/253) in male and 73.2% (112/153) in female.The GA/AA genotype and A allele frequency were higher in H-type hypertension group than in non H-type hypertension group [37.2 % (124/333) vs.16.4 % (12/73) and 21.3%(71/333) vs.9.6%(7/73),P=0.001and 0.021].Serum Hcyleveland the prevalence of H type hypertension were higher in GA/AA genotype group than in GG genotype group(both P< 0.05).Logistic regression analysis showed that GA/AA genotype,gender (male),drinking,folate deficiency and increased systolic pressure were the risk factors for H-type hypertension (OR=3.17,2.14,2.37,0.75,1.03,respectively,all P< 0.05).Conclusions The genetic variation of ALDH2(rs671) may increase Hcy level by decreasing the levels of folate and vitamin B12.GA/AA genotype is a risk factor for H-type hypertension,and it contributes to H-type hypertension together with gender,drinking history,folate levels and systolic pressure.
6.The cleaning of plaque biofilm on the surface of macromolecule ocular prosthesis material
Suping GUO ; Yan SONG ; Fantao WANG ; Xin XU ; Wei JIA
Chinese Journal of Tissue Engineering Research 2015;(43):6993-6997
BACKGROUND:The micro-ecological environment has been broken when the ocular prosthesis was inset into the conjunctival sac. The recede of self cleaning function is more conducive to the microbial growth and colonization. The cleaning of plaque biofilm on ocular prosthesis surface affects the patient's wearing comfort and quality of life. It is necessary to seek an effective cleaning method. OBJECTIVE:To compare the clearance effect of five cleaning methods on the palque biofilm on ocular prosthesis surface. METHODS: The conjunctival secretions from 84 patients who were subjected to ocular prosthesis repair were taken for bacterial culture and identification. Fifty pieces of self-curing resin and thermosetting resin artificial eyes were produced. The artificial eyes in each group were randomly divided into five groups, and were cleaned respectively with clear water, volume fraction of 75% ethanol, Boston SIMPLUS, polident and toothpaste. After the completion of the cleaning, the test piece was conducted residual biofilm culture. The clearance effects of different processing modes were evaluated using colony counting method. RESULTS AND CONCLUSION: Eighty-four specimens were submitted for inspection, of which 49 were positive. The Staphylococcusaureus separation rate was 14.29%.Staphylococcus epidermidis separation rate accounted for 13.10%. Maxwel Corynebacterium separation rate accounted for 7.14%. When water, Boston SIMPLUS and toothpaste were used for cleaning, theStaphylococcus aureus colony number in the self-curing resin group was higher than that in the thermosetting resin group (P< 0.05); when ethanol and polident were used for cleaning, there was no difference in the Staphylococcus aureus colony number between these two groups. In self-curing resin, the colony count in the clear water treatment group was higher than that in the other treatment groups (P < 0.05). The colony count in the ethanol treatment group was lower than that in the Boston SIMPLUS group (P < 0.05). There was no significant difference in the colony count between other groups. In thermosetting resin, the colony count in the clear water treatment group was higher than that in the other treatment groups (P < 0.05). There was no significant difference in the colony count between other groups. These results demonstrate that ethanol, Boston SIMPLUS, polident and toothpaste have better cleaning effects onStaphylococcus aureusbiofilms on the surface of two kinds of ocular prostheses than the clear water rinse. Overal, it is encouraged to clean the artificial eyes using polident and Boston SIMPLUS, in order to avoid the occurrence of microbial infection in the conjunctival sac after wearing ocular prosthesis.
7.Severe kyphosis in thoracolumbar fracture patients with injured intervertebral disc after posterior fixation
Xiaodong WEI ; Hongliang SONG ; Weiming GONG ; Tanghong JIA
Chinese Journal of Tissue Engineering Research 2016;20(17):24441-24447
BACKGROUND:Thoracolumbar fracture often accompanies with the injury of adjacent intervertebral disc. Traditional posterior short-segment fixation does not deal with the injured intervertebral disc, which may be the main reason for kyphosis in patients after surgery.
OBJECTIVE:To investigate the effect of injured intervertebral disc on kyphosis angle in patients with single vertebral thoracolumbar fracture after treated with posterior short-segment fixation alone.
METHODS:From January 2009 to June 2014, 40 cases of thoracolumbar fractures were treated in Jinan Central Hospital. They were folowed-up at preoperation, 2 and 12 months after operation and 6 months after internal fixation removal. Data were obtained from X-ray and MRI scanning. According to the preoperative MRI images, cases were assigned to observation group (17 cases) and control group (23 cases) according to injury and non-injury intervertebral disc. Data of vertebral wedge angle, sagittal plane kyphosis, proximal intervertebral disc angle, sagittal index and degeneration classification of proximal intervertebral disc angle from two different groups were analyzed at each folow-up time point (18-30 months, averagely 23.6 months).
RESULTS AND CONCLUSION:(1) Imaging parameters: sagittal plane kyphosis was significantly severer at 6 months than that at 2 months in both groups (P < 0.05). Sagittal plane kyphosis, proximal intervertebral disc angle and sagittal index were greater in the observation group than in the control group at 12 months after surgery and 6 months after fixator removal (P < 0.05). (2) Degeneration classification of proximal intervertebral disc angle: Pearce degeneration grade of proximal intervertebral disc was significantly higher in the observation group than in the control group at 2 months after surgery and 6 months after internal fixation removal (P < 0.05). (3) Results suggested that kyphosis may appear in the patients with thoracolumbar fracture after a posterior short-segment fixation alone, and the injured disc may lead to more severe kyphosis.
8.The risk factors of systemic inflammatory response syndrome after endovascular aortic repair of the aortic aneurysm
Tao ZHANG ; Jiang XIONG ; Xin JIA ; Senhao JIA ; Jie LIU ; Yingchun SONG ; Wei GUO
Chinese Journal of General Surgery 2012;(12):992-995
Objective To explore the relationship between the endovascular aortic repair (EVAR)in patients with abdominal aortic aneurysm (AAA) and postoperative systemic inflammatory response syndrome (SIRS).Methods In this study,93 AAA patients undergoing EVAR were enrolled.Analysis was performed to evaluate the incidence of SIRS during peri-operation period.Logistic multiple regression analysis was performed to determine the parameters predicting SIRS.Results The incidence of SIRS was 58.1%.Aneurysm size,mural thrombus,iliac artery lesion,number of stent,operating time,volume of contrast agent,blood loss and length of stay were all significantly correlated with SIRS (P < 0.05).In a logistic regression model,history of kidney disease or operation,aneurysm size,ruptured aneurysm and number of stents were strongly and independently associated with SIRS.Conclusions SIRS is common in AAA patients after EVAR.Optimizing treatment strategies avoiding risk factors for SIRS benefits AAA patients.
10.BRAF V600E Mutation as a Predictive Factor of Anti-EGFR Monoclonal Antibodies Therapeutic Effects in Metastatic Colorectal Cancer:a Meta-analysis
Qi Wang,Wei-guo Hu,Qi-bin Song, ; Wei JIA
Chinese Medical Sciences Journal 2014;(4):197-203
Objective To investigate the correlation between BRAF V600E mutation and anti-epidermal growth factor receptor (EGFR) monoclonal antibodies (MoAbs) therapeutic effects in metastatic colorectal cancer.
Methods Studies were included into meta-analysis to investigate the association between BRAF V600E mutation and clinical outcome in metastatic colorectal cancer patients treated with anti-EGFR MoAbs.
Results A total of 7 studies were included in this meta-analysis. The 7 studies included 1352 patients in total, sample sizes ranged from 67 to 493. Objective response rate (ORR), progression-free survival (PFS) and overall survival (OS) were collected from included studies and were used to assess the strength of the relation. In patients with wild-type KRAS, the pooled odds ratio for ORR of mutant BRAF over wild-type BRAF was 0.27 (95%CI=0.10-0.70). BRAF mutation predicted a deterioration in PFS and OS in wild-type KRAS patients treated with anti-EGFR MoAbs (hazard ratio=2.78, 95% CI=1.62-4.76;hazard ratio=2.54, 95%CI=1.93-3.32).
Conclusion BRAF V600E mutation is related to lack of response and worse survival in wild-type KRAS metastatic colorectal cancer patients treated with anti-EGFR MoAbs.