1.Design of high-frequency ultrasound grayscale blood flow imaging system based on field programmable gate array
Xiaochun WANG ; Jianjun JI ; Jun YANG ; Yanqun WANG ; Sheng ZHOU
Chinese Medical Equipment Journal 2017;38(2):11-15
Objective To develop a set of high-frequency ultrasound grayscale blood flow imaging system based on field programmable gate array (FPGA) to execute simultaneous imaging of superficial blood flow and tissues.Methods This system was mainly composed of an ultrasonic transducer,an ultrasonic transmission and receiving modules,imaging software in host computer and peripheral equipment.A PVDF transducer with the frequency between 20 and 50 MHz was used for the ultrasonic transducer.In transmission and receiving modules,the radio frequency echo signals were digitized by high-speed A/D.Then the digital signals were transmitted,added,filtered,demodulated,log amplified,double sampled,and lastly transferred to the host computer by USB interface for real-time display.Results A vascular 1 mm far form the surface of the hand skin was examined by this system.Four blood flow images were obtained in corresponding with four transmission frequencies.Conclusion Real-time superficial organ blood flow imaging is realized by this system.The solution has the architecture concise and clear,and lays an experimental foundationfor high-frequency ultrasound gray-scale blood flow imaging.
2.Therapeutic Observation on Treatment of Infantile Diarrhea with Tuina on Differentiation of Acupoints
Ji XU ; Hongyong DENG ; Lei JING ; Sheng ZHOU ; Hanting ZHU
Journal of Acupuncture and Tuina Science 2007;5(3):188-190
Infantile diarrhea was divided into four types of wind cold,damp heat,food injury and spleen deficiency on differentiation of symptoms and signs.The techniques of tonifying the spleen,clearing Dachang(large intestine),rubbing the abdomen and pressing Zhixie (stopping diarrhea) point,Zusanli (ST 36) and Changqiang (GV 1) as well as pinching the spine were chosen to treat this disease with a satisfactory result.
5.Research and realization of signal processing algorithms based on FPGA in digital ophthalmic ultrasonography imaging.
Simin FANG ; Sheng ZHOU ; Xiaochun WANG ; Qingsheng YE ; Ling TIAN ; Jianjun JI ; Yanqun WANG
Chinese Journal of Medical Instrumentation 2015;39(1):1-4
OBJECTIVETo design and improve signal processing algorithms of ophthalmic ultrasonography based on FPGA.
METHODSAchieved three signal processing modules: full parallel distributed dynamic filter, digital quadrature demodulation, logarithmic compression, using Verilog HDL hardware language in Quartus II.
RESULTSCompared to the original system, the hardware cost is reduced, the whole image shows clearer and more information of the deep eyeball contained in the image, the depth of detection increases from 5 cm to 6 cm.
CONCLUSIONThe new algorithms meet the design requirements and achieve the system's optimization that they can effectively improve the image quality of existing equipment.
Algorithms ; Data Compression ; Diagnostic Imaging ; Ophthalmology ; Signal Processing, Computer-Assisted ; Ultrasonography
6.Quantitative analysis of contrast-enhanced ultrasonography in differentiating acute rejection from acute tubular necrosis of transplant kidney
Wanyuan HE ; Sheng ZHOU ; Cheng YANG ; Yunjie JIN ; Zhengbiao JI ; Wenping WANG
Chinese Journal of Ultrasonography 2014;(11):952-956
Objective To evaluate the value of quantitative analysis of contrast‐enhanced ultrasonography (CEUS) in differentiating acute rejection(AR) from acute tubular necrosis(ATN) of transplant kidney. Methods Total of 67 kidney recipients were examined with conventional US and CEUS. Biopsies were performed in 37 patients, 26 patients were with AR, 11 with ATN, 30 patients as control group. The hemodynamic parameters (PSV and RI) were measured on infrarenal artery with conventional US, while CEUS quantitative analysis was performed on the cortex, pyramid and interlobar artery by time‐intensity curve (TIC). TIC parameters including rise time (RT ), time to peak (TTP), mean transit time (mTT ) were compared among three groups. In addition, the reproducibility of TIC parameters was evaluated. Results The RI in AR group was significantly higher than that in control group, but there were no significant differences of RI between AR and ATN groups. TIC parameters including RT, TTP were with high reproducibility (ICC> 0 7.5). Compared to the other two groups, the RT and TTP of the pyramid, ΔRTm‐c, and ΔTTPm‐c were significantly longer in AR group, the receiver operating curves (ROC) analysis demonstrated that ΔRTm‐c had the highest accuracy and RI had the lowest accuracy for detecting AR(areas under the curve were 0 7.86, 0 7.56, 0 7.49, 0 7.36 and 0 4.98, respectively). High sensitivity and specificity(78 3.% and 73 5.%, respectively) were shown when using 4 6.2 s as a cutoff point of ΔRTm‐c to diagnose AR. Conclusions Quantitative analysis of CEUS could detected the changes of the microcirculation perfusion in kidney grafts with AR and ATN, which might be superior in the diagnosis of AR compared with conventional US.
7.The clinicopathologic characteristics of desmoplastic fibroblastoma in neck and nape
Caiping HUANG ; Hongshi WANG ; Qinghai JI ; Weiqi SHENG ; Zhengrong ZHOU ; Weihong WU
Chinese Archives of Otolaryngology-Head and Neck Surgery 2006;0(06):-
OBJECTIVE To describe the clinical, CT or MRI, pathological characteristics of desmoplastic fibroblastoma for helping the diagnosis and treatment. METHODS The clinical data of 4 cases with desmoplastic fibroblastoma were retrospectively analyzed. RESULTS The tumors of all 4 cases were found in the compartment of muscles, and can be removed by conservative excision. The 4 cases were followed up for 38, 7, 6, 3 months respectively, and no local recurrences were found. CONCLUSION Desmoplastic fibroblastoma is a benign fibroblastic neoplasm with distinctive clinical, CT or MRI imaging and pathological characteristics. Optimal management is conservative excision with functional preservation. Needle aspiration cytology and immunohistochemistry are of non-diagnostic value.
8.PI3 K/Akt/Sirt1 signaling pathway mediated hydrogen sulfide postconditioning-induced protection against I/R injury
Mingzhu HU ; Bo ZHOU ; Qiong SHENG ; Bin DU ; Junliang CHEN ; Qingfeng PANG ; Yong JI
Chinese Pharmacological Bulletin 2016;(2):268-273
Aim To explore the role of PI3 K/Akt/Sirt1 pathway in cardioprotection of hydrogen sulfide ( H2 S ) postconditioning against ischemia/reperfusion ( I/R) injury. Methods Langendorff perfusion appa-ratus was used to build an isolated rat myocardial I/R model. Isolated rat hearts were subjected to 30 min global ischemia followed by 60 min reperfusion after 20 min of equilibrium. 60 male SD rats were randomly di-vided into 5 groups(n=12):control group(Control), ischemia/reperfusion group( I/R) , H2 S postcondition-ing group( H2 S) , inhibitor LY294002 group( LY) and H2 S with inhibitor group( H2 S+LY) . The left ventric-ular diastolic pressure ( LVEDP ) , the left ventricular developed pressure(LVDP), the maximum rate of in-crease or decrease of left ventricular pressure ( ± dp/dtmax ) were registered at the end of 20 min equilibri-um, 30 and 60 min of reperfusion separately. Triphe-nyl tetrazolium chloride( TTC) staining was used to de-termine the myocardial infarct size. The levels of Sirt1 and PGC-1 mRNA were tested using real-time PCR. The expressions of Sirt1 and PGC-1αwere detected with Western blot analysis. Immunohistochemical method was used to determine the location of Sirt1 . Results There were no differences in equilibrium hemodynamics observed between the experimental groups(P>0. 05). At the end of reperfusion, compared with I/R group, H2 S group had obviously ameliorated functional recov-ery and significantly decreased the myocardial infarct size(26. 9 ± 4. 9)% vs(48. 9 ± 5. 6)%(P <0. 05). Meanwhile, the expression of Sirt1 and PGC-1α in-creased significantly. However,LY294002 reversed the cardioprotective effects provided by hydrogen sulfide postconditioning and reduced the level of Sirt1 and PGC-1α, the percentage of Sirt1-positive nuclei. Con-clusion PI3 K/Akt/Sirt1 signaling pathway mediates the hydrogen sulfide postconditioning-induced protec-tion against I/R injury.
9.Noninvasive evaluation of renal allograft fibrosis by virtual touch tissue quantification
Wanyuan HE ; Sheng ZHOU ; Cheng YANG ; Yunjie JIN ; Zhengbiao JI ; Yuli ZHU ; Wenping WANG
Chinese Journal of Ultrasonography 2015;24(11):976-979
Objective To evaluate the diagnostic value of virtual touch tissue quantification (VTQ) in the diagnosis of renal allograft fibrosis.Methods The renal allografts of 82 patients with biopsies or nephrectomy were assessed by virtual touch quantification.The renal allograft fibrosis was categorized according to the 2005 updated Banff criteria for a G0~G3 grade.All the results were compared among four groups.Results The mean SWV values in G0~G3 were (2.39 ± 0.31)m/s,(2.45 ± 0.34)m/s,(2.58 ± 0.18) m/s,(3.11 ± 0.40)m/s,respectively.There were no significant differences in the mean SWV value between G0 and G1 group,or between G1 and G2 group(P >0.05).There were significant differences in the mean SWV value between G0~G2 and G3 group,or between G0 and G2 group(P <0.05).Stiffness of renal allograft was significantly correlated to the mean SWV value (Spearman r =0.671,P <0.001).According to the area under the ROC curve,the sensitivity and specificity of SWV (area under ROC curve =0.847,cut-off=2.64 m/s) for grade ≥G2 was 78.9% and 79.5% respectively.Conclusions Stiffness measured by VTQ reflects the interstitial fibrosis in renal allograft.VTQ technique might be a new tool to identify patients with chronic allograft injury.
10.Design and realization of 1024-point high-speed FFT processor based on FPGA
Wenfang WANG ; Sheng ZHOU ; Xiaochun WANG ; Liwei WANG ; Jianjun JI ; Jun YANG ; Yanqun WANG
International Journal of Biomedical Engineering 2011;34(4):205-208
ObjectiveTo design a fast fourier transform (FFT) processor to meet the needs for high-speed and real-time signal processing. MethodsA 1 024-point, 32-bit, fixed, complex FFT processor was designed based on field programmable gate array (FPGA) by using radix-2 decimation in frequency(DIF) algorithm and pipeline structure in the butterfly module and ping-pong operation in data storage unit. ResultsWhen the primary clock was 100 MHz, 1 024-point FFT calculation took about 62.95us. The processor was fast enough for processing highspeed and real-time signals. ConclusionThe results provides reference value that theoretical study of the FFT algorithm can be applied in the adaptive dynamic filter of ultrasonic diagnostic system and ultrasonic doppler flow measurement system.