1.The Impact of Clinical Competence and Perception of Clinical Ladder System on Organizational Commitment among Nurses at a General Tertiary Hospital
Yeon Hee SHIN ; Mi Ra LEE ; Sung Nam KIM ; Min Jung KIM ; Ae Jin KIM ; Hyun Ja KIM ; Ji Yoon KANG
Journal of Korean Academy of Nursing Administration 2025;31(1):120-131
Purpose:
This study aimed to evaluate the performance of a clinical ladder system in a tertiary hospital by examining how nurses' clinical competence and perceptions of the system affect organizational commitment.
Methods:
The study involved 394 nurses working at a tertiary hospital. Data were collected from May 3 to July 10, 2023, using a self-reported questionnaire. Statistical analyses, including descriptive statistics, independent t-tests, one-way ANOVA, Kruskal-Wallis test, Scheffé post-hoc test, Pearson correlation, and hierarchical regression analysis, were performed using SPSS 27.0.
Results:
Nurses who applied for promotion to the CN III level and current CN III nurses reported higher clinical competence, perceptions of the clinical ladder system, and organizational commitment than those who did not and those at lower levels (p<.001). A positive correlation existed among all independent variables.Controlling for general characteristics, the effects of clinical competence and perceptions of the clinical ladder system explained 49% of organizational commitment variance (Adjusted R 2 =.49, F=33.43, p<.001).
Conclusion
Greater clinical competence and positive perceptions of the clinical ladder system are likely to enhance organizational commitment, emphasizing its effectiveness in fostering better organizational outcomes.
2.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.
3.The Impact of Clinical Competence and Perception of Clinical Ladder System on Organizational Commitment among Nurses at a General Tertiary Hospital
Yeon Hee SHIN ; Mi Ra LEE ; Sung Nam KIM ; Min Jung KIM ; Ae Jin KIM ; Hyun Ja KIM ; Ji Yoon KANG
Journal of Korean Academy of Nursing Administration 2025;31(1):120-131
Purpose:
This study aimed to evaluate the performance of a clinical ladder system in a tertiary hospital by examining how nurses' clinical competence and perceptions of the system affect organizational commitment.
Methods:
The study involved 394 nurses working at a tertiary hospital. Data were collected from May 3 to July 10, 2023, using a self-reported questionnaire. Statistical analyses, including descriptive statistics, independent t-tests, one-way ANOVA, Kruskal-Wallis test, Scheffé post-hoc test, Pearson correlation, and hierarchical regression analysis, were performed using SPSS 27.0.
Results:
Nurses who applied for promotion to the CN III level and current CN III nurses reported higher clinical competence, perceptions of the clinical ladder system, and organizational commitment than those who did not and those at lower levels (p<.001). A positive correlation existed among all independent variables.Controlling for general characteristics, the effects of clinical competence and perceptions of the clinical ladder system explained 49% of organizational commitment variance (Adjusted R 2 =.49, F=33.43, p<.001).
Conclusion
Greater clinical competence and positive perceptions of the clinical ladder system are likely to enhance organizational commitment, emphasizing its effectiveness in fostering better organizational outcomes.
4.Sentinel Safety Monitoring System for Adverse Events of Special Interest Associated With Non-NIP Vaccines in Korea
Hakjun HYUN ; Jung Yeon HEO ; Yu Jung CHOI ; Eliel NHAM ; Jin Gu YOON ; Ji Yun NOH ; Joon Young SONG ; Woo Joo KIM ; Won Suk CHOI ; Min Joo CHOI ; Yu Bin SEO ; Jacob LEE ; Hee Jin CHEONG
Journal of Korean Medical Science 2025;40(16):e152-
South Korea’s current vaccination policies leave a surveillance gap for non-National Immunization Program (NIP) vaccines. In this study, we proposed a sentinel surveillance approach for monitoring the safety of non-NIP vaccines. Vaccination data were collected retrospectively among patients hospitalized with pre-defined adverse events of special interest (AESI) by reviewing electronic medical records in five university hospitals. This approach incorporates expert assessment to determine the causal relationship. We confirmed that 16 patients had received non-NIP vaccines among 860 patients diagnosed with AESI.We concluded one case of preeclampsia was possibly related to tetanus-diphtheria-pertussis vaccination. We propose a multi-hospital-based, retrospective assessment system for predefined AESIs as an alternative to active vaccine safety monitoring method. These efforts are expected to enhance both the accuracy and timeliness of safety monitoring in South Korea.
5.Testing the reliability and validity of the Korean version of the Pittsburgh Sleep Quality Index using Fitbit devices: a cross-sectional analysis
Si-Yeon LEE ; Ja-Eun CHOI ; Ji-Won LEE ; Yaeji LEE ; Jae-Min PARK ; Kyung-Won HONG
Korean Journal of Family Medicine 2025;46(1):42-47
Background:
Sleep disorders and insomnia are prevalent worldwide, with negative health outcomes. The Pittsburgh Sleep Quality Index (PSQI) is a widely used self-report assessment tool for evaluating sleep quality, comprising seven subdomains. The Korean version of the PSQI (PSQI-K) has been tested for reliability and validity in small sample sizes but lacks large-scale validation using objective measures.
Methods:
This study was conducted with 268 Korean adults attending health check programs. Participants completed the PSQI-K questionnaire and wore Fitbit devices (Fitbit Inc., USA) to ascertain sleep parameters. Reliability was analyzed using the Cronbach’s α coefficient, and construct validity was determined through factor analysis. Criteria validity was assessed by correlating their index scores with Fitbit sleep parameters. We identified the optimal cutoff for detecting sleep disorders.
Results:
The Cronbach’s α coefficient was 0.61, indicating adequate internal consistency. Factor analysis revealed three factors, explaining 48.2% of sleep quality variance. The index scores were negatively correlated with Fitbit sleep efficiency, total sleep time, and number of awakenings (P<0.05). The optimal cutoff point for identifying sleep disorder groups was ≥6.
Conclusion
The PSQI-K demonstrated good reliability and validity when correlated with Fitbit sleep parameters, offering a practical screening tool for identifying sleep disorders among Korean adults. Cutoff scores can help identify patients for sleep interventions. However, further large-scale studies are required to validate these findings.
6.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
7.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
8.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.
9.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.
10.Unlocking the Potential of Chest MRI: Strategies for Establishing a Successful Practice
Kyubin KIM ; Kun-Il KIM ; Ji Won LEE ; Yeon Joo JEONG
Journal of the Korean Society of Radiology 2025;86(1):83-104
Chest MRI is a valuable tool for assessing chest structures, particularly when CT produces inconclusive results. MRI provides exceptional soft-tissue resolution and enables the determination of lesion location, size, and invasion into neighboring structures. Its applications span various clinical scenarios, including the differentiation of non-tumorous and tumorous conditions in the mediastinum or pleura, planning of surgical interventions and treatments for such tumors, evaluation of post-treatment recurrence, staging of lung cancer, and diagnosis of progressive massive fibrosis. Despite the technical hurdles posed by cardiac and respiratory motion, advancements in sequence and scan techniques have enabled high-quality chest MRI examinations to be conducted across diverse clinical settings. This pictorial essay aims to offer comprehensive resources and strategies for radiologists to integrate chest MRI into clinical practice and to overcome its present challenges.

Result Analysis
Print
Save
E-mail