1.Knowledge and Practice of Dental Practitioners Regarding Patient's Personal Information.
Journal of Dental Hygiene Science 2017;17(2):99-107
The purpose of this study was to identify knowledge awareness, and performance of dentist and dental staff regarding protection of patient's personal information. In addition, this research was conducted to highlight the importance of protection of patient's personal information and provide a guideline for establishing measures in this regard. A survey was conducted on 506 dentists or dental staff working in Seoul, Gyeonggi and Chungcheong provinces. The data was analyzed using t-test, one-way ANOVA, χ2, Pearson's correlation coefficient, and Scheffe test, using the PASW Statistics ver. 18.0 program. We found that the participants' knowledge and perception of the protection of patient's personal information were relatively low compared to those of other professionals. Such knowledge and perception were especially and significantly low in dental hygienists. In addition, a high level of knowledge and awareness showed a positive correlation with the extent of performance. Therefore, it is important that dentists and dental staff are aware of issues regarding the protection of patients' personal information. For this purpose, educational and training programs on such issues appear essential.
Dental Hygienists
;
Dental Staff
;
Dentists
;
Education
;
Gyeonggi-do
;
Humans
;
Seoul
2.A Study on the Retentive Force of Stud Attachments for Implant Overdenture.
Eun Ju SONG ; Eun Bin BAE ; Jae Won CHOI ; Ji Hyeon BAE ; Ji Young KIM ; So Hyoun LEE
Journal of Dental Hygiene Science 2016;16(1):93-100
The purpose of this study was to compare the changes of retentive force in different stud attachment systems for implant retained overdenture. Two commercially available attachments with different retentive forces were investigated: Kerator (pink, blue, red) and O-ring (orange, red). Two implant fixtures were vertically embedded in base mountings. Five pairs of each attachment were evaluated. A universal testing machine was used to evaluate the retentive force of two attachments during wear simulation. Surface characteristics of each attachment system were evaluated with scanning electron microscopy. Five pairs of each attachment were evaluated. Kerator pink showed the highest initial retention. After 2,500 cycles of wear-simulation, Kerator pink noted the largest decrease in retention. According to results of surface analysis, Worn surfaces were obtained in matrices and patrices. Heavy wears were observed in matrices. After 2 year-wear simulation, most attachments exhibited retention loss. Attachments using different kind of material exhibited dissimilar surface alterations.
Denture, Overlay*
;
Microscopy, Electron, Scanning
3.Implant-assisted removable partial denture using milled bar and Locatorin partially edentulous maxilla: A case report
Ji-Hyun KIM ; Chang-Mo JEONG ; Mi-Jung YUN ; Jung-Bo HUH ; Hyeon-Jong LEE ; So-Hyoun LEE
The Journal of Korean Academy of Prosthodontics 2020;58(2):137-144
were satisfactory on the aspect of esthetic and masticatory function. (J Korean Acad Prosthodont 2020;58:137-44)
4.Standardized, musculoskeletal ultrasonographic reference values for healthy Korean adults
Hyun Sook KIM ; Hae Rim KIM ; Bo Young KIM ; Yun Sung KIM ; Young Ok JUNG ; Sung Jae CHOI ; Hyun Ok KIM ; Jiwon HWANG ; Sunggun LEE ; Hyoun Ah KIM ; So Young BANG ; Ji Young CHAI ; Sung Hoon PARK ; Chong Hyeon YOON
The Korean Journal of Internal Medicine 2019;34(6):1372-1380
BACKGROUND/AIMS:
To define standard reference values for musculoskeletal ultrasonography (MSUS) in Korea.
METHODS:
A total of 251 healthy adults were recruited for this study. Ultrasonography was performed by experienced rheumatologists who had undergone four appropriate training programs in Korea. A General Electric LOGIQ electronic ultrasound device fitted with a 12 MHz linear transducer was employed. Mean values ± standard deviations (SDs) were defined as standard reference values. Intraclass correlation coefficients was employed to evaluate the extent of inter- and intraobserver agreement when MSUS measurements were made.
RESULTS:
The 251 study participants included 122 males. Mean subject age was 28.6 years. The average bone-to-capsule distance of the right-side second and third metacarpophalangeal (MCP) joints were 0.68 and 0.72 mm respectively, and those of the left-side joints 0.62 and 0.68 mm. The cartilage thicknesses of the right-side second and third MCP joints were 0.55 and 0.55 mm, and those of the left-side joints were 0.55 and 0.56 mm, respectively. The bone-to-capsule distances of the right and left wrists were 0.80 and 0.82 mm. In 12.4% of participants (31/251), the erosion score of the humeral head was 1.71. In the right-side knee joint, mean cartilage thicknesses of the medial and lateral condyles were 1.86 and 2.03 mm in longitudinal scans. High overall interobserver agreement was evident after appropriate training that included instruction on standard MSUS methodology.
CONCLUSIONS
We defined standard reference values for MSUS in healthy Korean adults. The reliabilities of interobserver agreements were high after appropriate training program.