1.Two Cases of Recurrent Extramammary Paget's Disease after Wide Local Excision.
Sang Jun LEE ; Min Ja JUNG ; Yoon Whoa CHO ; Jee Yoon HAN ; Jeong Rye KIM
Korean Journal of Dermatology 1997;35(3):561-565
We report two cases of recurrent extramarnmary Pagets disease after wide local excision. Both cases involved the scrotum and the penoserotal junction, respectively. On histopathological examination, we could observed many Paget cells confined to the epidermis and the hair follicle, but not invading the underlying dermis in both cases. There was no evidence of internal malignancy. Both cases were treated with wide local reexcision.
Dermis
;
Epidermis
;
Hair Follicle
;
Paget Disease, Extramammary*
;
Scrotum
2.The Impact of Cortical Cerebral Microinfarcts on Functional Outcomes in Patients With Ischemic Stroke
Jeong A HAM ; Yoon Jeong JEONG ; Min Kyeong MA ; Hyun Im MOON
Brain & Neurorehabilitation 2022;15(3):e30-
The present study examined cortical cerebral microinfarcts (CMIs) on a 3T magnetic resonance imaging and investigated the impact of CMIs on the comprehensive functional outcomes during the post-stroke rehabilitation period. Patients with acute phase of firstever ischemic stroke were retrospectively recruited (n = 62) and divided into 2 groups with and without CMIs. Clinical parameters including age, sex, stroke lesion laterality, location, the National Institutes of Health Stroke Scale score, as well as history of hypertension, dyslipidemia, diabetes mellitus, and smoking were obtained. Functional outcomes were assessed twice at baseline and one month later with the Korean version of the MiniMental State Examination, the Berg balance scale (BBS), and the functional independence measure. Partial correlation and multiple linear regression analyses were used to examine the relationship between the presence of CMIs and the change in functional outcomes. At least one CMI was reported in 27 patients, who were older (p = 0.043). The presence of CMIs was significantly associated with functional impairment in all 3 functional outcomes, after controlling for confounding factors (p < 0.05). CMIs might contribute to poor functional outcomes during the post-stroke rehabilitation period. These results suggest that CMIs should be considered when establishing rehabilitation treatment strategies or making a prognosis.
3.Erratum: Noninvasive Diagnosis of Hepatocellular Carcinoma: Elaboration on Korean Liver Cancer Study Group-National Cancer Center Korea Practice Guidelines Compared with Other Guidelines and Remaining Issues.
Jeong Hee YOON ; Joong Won PARK ; Jeong Min LEE
Korean Journal of Radiology 2016;17(2):306-306
The original article contained incorrect figure captions.
4.Noninvasive Diagnosis of Hepatocellular Carcinoma: Elaboration on Korean Liver Cancer Study Group-National Cancer Center Korea Practice Guidelines Compared with Other Guidelines and Remaining Issues.
Jeong Hee YOON ; Joong Won PARK ; Jeong Min LEE
Korean Journal of Radiology 2016;17(1):7-24
Hepatocellular carcinoma (HCC) can be diagnosed based on characteristic findings of arterial-phase enhancement and portal/delayed "washout" in cirrhotic patients. Several countries and major academic societies have proposed varying specific diagnostic criteria for HCC, largely reflecting the variable HCC prevalence in different regions and ethnic groups, as well as different practice patterns. In 2014, a new version of Korean practice guidelines for management of HCC was released by the Korean Liver Cancer Study Group (KLCSG) and the National Cancer Center (NCC). According to the KLCSG-NCC Korea practice guidelines, if the typical hallmark of HCC (i.e., hypervascularity in the arterial phase with washout in the portal or 3 min-delayed phases) is identified in a nodule > or = 1 cm in diameter on either dynamic CT, dynamic MRI, or MRI using hepatocyte-specific contrast agent in high-risk groups, a diagnosis of HCC is established. In addition, the KLCSG-NCC Korea practice guidelines provide criteria to diagnose HCC for subcentimeter hepatic nodules according to imaging findings and tumor marker, which has not been addressed in other guidelines such as Association for the Study of Liver Diseases and European Association for the Study of the Liver. In this review, we briefly review the new HCC diagnostic criteria endorsed by the 2014 KLCSG-NCC Korea practice guidelines, in comparison with other recent guidelines; we furthermore address several remaining issues in noninvasive diagnosis of HCC, including prerequisite of sonographic demonstration of nodules, discrepancy between transitional phase and delayed phase, and implementation of ancillary features for HCC diagnosis.
Aged
;
Aged, 80 and over
;
Carcinoma, Hepatocellular/*diagnosis/pathology
;
Contrast Media
;
Female
;
Hepatitis B, Chronic/complications
;
Hepatitis C, Chronic/complications
;
Humans
;
Liver/*pathology
;
Liver Neoplasms/*diagnosis/pathology
;
Magnetic Resonance Imaging/*methods
;
Male
;
Middle Aged
;
Practice Guidelines as Topic
;
Republic of Korea
;
Young Adult
5.Comparison of Ablation Performance between Octopus Multipurpose Electrode and Conventional Octopus Electrode
Sae-Jin PARK ; Jae Hyun KIM ; Jeong Hee YOON ; Jeong Min LEE
Korean Journal of Radiology 2023;24(2):86-94
Objective:
To compare Octopus multipurpose (MP) electrodes, which are capable of saline instillation and direct tissue temperature measurement, and conventional electrodes for radiofrequency ablation (RFA) in porcine livers in vivo.
Materials and Methods:
Sixteen pigs were used in this study. In the first experiment, RFA was performed in the liver for 6 minutes using Octopus MP electrodes (n = 15 ablation zones) and conventional electrodes (n = 12 ablation zones) to investigate the effect of saline instillation. The ablation energy, electrical impedance, and ablation volume of the two electrodes were compared. In the second experiment, RFA was performed near the gallbladder (GB) and colon using Octopus MP electrodes (n = 12 ablation zones for each) with direct tissue temperature monitoring and conventional electrodes (n = 11 ablation zones for each). RFA was discontinued when the temperature increased to > 60°C in the Octopus MP electrode group, whereas RFA was performed for a total of 6 minutes in the conventional electrode group. Thermal injury was assessed and compared between the two groups by pathological examination.
Results:
In the first experiment, the ablation volume and total energy delivered in the Octopus MP electrode group were significantly larger than those in the conventional electrode group (15.7 ± 4.26 cm3 vs. 12.5 ± 2.14 cm3 , p = 0.027; 5.48 ± 0.49 Kcal vs. 5.04 ± 0.49 Kcal, p = 0.029). In the second experiment, thermal injury to the GB and colon was less frequently noted in the Octopus MP electrode group than that in the conventional electrode group (16.7% [2/12] vs. 90.9% [10/11] for GB and 8.3% [1/12] vs. 90.9% [10/11] for colon, p < 0.001 for all). The total energy delivered around the GB (2.65 ± 1.07 Kcal vs. 5.04 ± 0.66 Kcal) and colon (2.58 ± 0.57 Kcal vs. 5.17 ± 0.90 Kcal) were significantly lower in the Octopus MP electrode group than that in the conventional electrode group (p < 0.001 for all).
Conclusion
RFA using the Octopus MP electrodes induced a larger ablation volume and resulted in less thermal injury to the adjacent organs compared with conventional electrodes.
6.Reproducibility of liver stiffness measurements made with two different 2-dimensional shear wave elastography systems using the comb-push technique
Hwaseong RYU ; Su Joa AHN ; Jeong Hee YOON ; Jeong Min LEE
Ultrasonography 2019;38(3):246-254
PURPOSE: The purpose of this study was to retrospectively compare the technical success and reliability of the measurements made using two 2-dimensional (2D) shear wave elastography (SWE) systems using the comb-push technique from the same manufacturer and to assess the intersystem reproducibility of the resultant liver stiffness (LS) measurements. METHODS: Ninety-four patients with suspected chronic liver diseases were included in this retrospective study. LS measurements were obtained using two 2D-SWE systems (LOGIQ E9 and LOGIQ S8) from the same manufacturer, with transient elastography (TE) serving as the reference standard, on the same day. The technical success rates and reliability of the measurements of the two 2D-SWE systems were compared. LS values measured using the two 2D-SWE systems and TE were correlated using Spearman correlation coefficients and 95% Bland-Altman limits of agreement. Thereafter, Bland-Altman limits of agreement and intraclass correlation coefficients (ICCs) were used to analyze the intersystem reproducibility of LS measurements. RESULTS: The two 2D-SWE systems showed similar technical success rates (98.9% for both) and reliability of LS measurements (92.3% for the LOGIQ E9, 91.2% for the LOGIQ S8; P=0.185). Despite the excellent correlation (ICC=0.92), the mean LS measurements obtained by the two 2D-SWE systems were significantly different (LOGIQ E9, 6.57±2.33 kPa; LOGIQ S8, 6.90±6.64 kPa; P=0.018). CONCLUSION: Significant intersystem variability was observed in the LS measurements made using the two 2D-SWE systems. Therefore, even 2D-SWE systems from the same manufacturer should not be used interchangeably in longitudinal follow-up.
Elasticity Imaging Techniques
;
Follow-Up Studies
;
Humans
;
Liver Cirrhosis
;
Liver Diseases
;
Liver
;
Reproducibility of Results
;
Retrospective Studies
;
Ultrasonography
7.Inter-platform reproducibility of liver stiffness measured with two different point shear wave elastography techniques and 2-dimensional shear wave elastography using the comb-push technique
Hwaseong RYU ; Su Joa AHN ; Jeong Hee YOON ; Jeong Min LEE
Ultrasonography 2019;38(4):345-354
PURPOSE: The purpose of this study was to compare the technical success rate and reliability of measurements made using three shear wave elastography (SWE) techniques and to assess the inter-platform reproducibility of the resultant liver stiffness measurements. METHODS: This prospective study included 54 patients with liver disease. Liver stiffness (LS) measurements were obtained using 2-point SWE techniques (Virtual Touch Quantification and S-Shearwave) and 2-dimensional (2D) SWE, with transient elastography (TE) serving as the reference standard. The technical success rates and measurement reliability of the three techniques were compared. LS values measured using the three SWE techniques and TE were compared using Spearman correlation coefficients and 95% Bland-Altman limits of agreement. Intra-class correlation coefficients (ICC) were used to analyze the inter-platform reproducibility of LS measurements. RESULTS: The three SWE techniques and TE showed similar technical success rates (P=0.682) but demonstrated significant differences in the reliability of LS measurements (P=0.006) and mean LS measurements (P<0.001). Despite strong correlations (r=0.73-0.94) between SWE systems, various degrees of inter-platform reproducibility (ICC, 0.58-0.92) were observed for the three SWE techniques. The best agreement was observed between S-Shearwave and TE (ICC, 0.92), and the worst agreement was observed between 2D-SWE and TE (ICC, 0.58). In the Bland-Altman analysis, a tendency toward lower LS values with the three SWE techniques than with TE in patients with F3 and F4 disease was observed. CONCLUSION: Significant inter-system variability was observed in LS measurements made using the three SWE techniques. Therefore, LS values measured using different SWE techniques should not be used interchangeably for longitudinal follow-up.
Elasticity Imaging Techniques
;
Follow-Up Studies
;
Humans
;
Liver Cirrhosis
;
Liver Diseases
;
Liver
;
Prospective Studies
8.Role of Contrast-Enhanced Ultrasound as a Second-Line Diagnostic Modality in Noninvasive Diagnostic Algorithms for Hepatocellular Carcinoma
Hyo-Jin KANG ; Jeong Min LEE ; Jeong Hee YOON ; Joon Koo HAN
Korean Journal of Radiology 2021;22(3):354-365
Objective:
To investigate the diagnostic performance of contrast-enhanced ultrasound (CEUS) and its role as a second-line imaging modality after gadoxetate-enhanced MRI (Gd-EOB-MRI) in the diagnosis of hepatocellular carcinoma (HCC) among at risk observations.
Materials and Methods:
We prospectively enrolled participants at risk of HCC with treatment-naïve solid hepatic observations (≥ 1 cm) of Liver Imaging Reporting and Data System (LR)-3/4/5/M during surveillance and performed Gd-EOB-MRI. A total of one hundred and three participants with 103 hepatic observations (mean size, 28.2 ± 24.5 mm; HCCs [n = 79], non-HCC malignancies [n = 15], benign [n = 9]; diagnosed by pathology [n = 57], or noninvasive method [n = 46]) were included in this study. The participants underwent CEUS with sulfur hexafluoride. Arterial phase hyperenhancement (APHE) and washout on Gd-EOB-MRI and CEUS were evaluated. The distinctive washout in CEUS was defined as mild washout 60 seconds after contrast injection. The diagnostic ability of Gd-EOB-MRI and of CEUS as a second-line modality for HCC were determined according to the European Association for the Study of the Liver (EASL) and the Korean Liver Cancer Association and National Cancer Center (KLCA-NCC) guidelines. The diagnostic abilities of both imaging modalities were compared using the McNemar’s test.
Results:
The sensitivity of CEUS (60.8%) was lower than that of Gd-EOB-MRI (72.2%, p = 0.06 by EASL; 86.1%, p < 0.01 by KLCA-NCC); however, the specificity was 100%. By performing CEUS on the inconclusive observations in Gd-EOB-MRI, HCCs without APHE (n = 10) or washout (n = 12) on Gd-EOB-MRI further presented APHE (80.0%, 8/10) or distinctive washout (66.7%, 8/12) on CEUS, and more HCCs were diagnosed than with Gd-EOB-MRI alone (sensitivity: 72.2% vs. 83.5% by EASL, p < 0.01; 86.1% vs. 91.1% by KCLA-NCC, p = 0.04). There were no false-positive cases for HCC on CEUS.
Conclusion
The addition of CEUS to Gd-EOB-MRI as a second-line diagnostic modality increases the frequency of HCC diagnosis without changing the specificities.
9.Emerging Role of Hepatobiliary Magnetic Resonance Contrast Media and Contrast-Enhanced Ultrasound for Noninvasive Diagnosis of Hepatocellular Carcinoma: Emphasis on Recent Updates in Major Guidelines
Tae Hyung KIM ; Jeong Hee YOON ; Jeong Min LEE
Korean Journal of Radiology 2019;20(6):863-879
Hepatocellular carcinoma (HCC) can be noninvasively diagnosed on the basis of its characteristic imaging findings of arterial phase enhancement and portal/delayed “washout” on computed tomography (CT) and magnetic resonance imaging (MRI) in cirrhotic patients. However, different specific diagnostic criteria have been proposed by several countries and major academic societies. In 2018, major guideline updates were proposed by the Association for the Study of Liver Diseases, European Association for the Study of the Liver (EASL), Korean Liver Cancer Association and National Cancer Center (KLCA-NCC) of Korea. In addition to dynamic CT and MRI using extracellular contrast media, these new guidelines now include magnetic resonance imaging (MRI) using hepatobiliary contrast media as the first-line diagnostic test, while the KLCA-NCC and EASL guidelines also include contrast-enhanced ultrasound (CEUS) as the second-line diagnostic test. Therefore, hepatobiliary MR contrast media and CEUS will be increasingly used for the noninvasive diagnosis and staging of HCC. In this review, we discuss the emerging role of hepatobiliary phase MRI and CEUS for the diagnosis of HCC and also review the changes in the HCC diagnostic criteria in major guidelines, including the KLCA-NCC practice guidelines version 2018. In addition, we aimed to pay particular attention to some remaining issues in the noninvasive diagnosis of HCC.
Carcinoma, Hepatocellular
;
Contrast Media
;
Diagnosis
;
Diagnostic Tests, Routine
;
Humans
;
Korea
;
Liver
;
Liver Diseases
;
Liver Neoplasms
;
Magnetic Resonance Imaging
;
Ultrasonography
10.Ultrasound-guided transient elastography and two-dimensional shear wave elastography for assessment of liver fibrosis: emphasis on technical success and reliable measurements
Jihyuk LEE ; Hyo-Jin KANG ; Jeong Hee YOON ; Jeong Min LEE
Ultrasonography 2021;40(2):217-227
Purpose:
This study investigated whether the use of ultrasound (US) guidance in transient elastography (TE) improved the technical success and reliability of liver stiffness (LS) measurements and whether 2-dimensional (2D) shear wave elastography (SWE) provided reliable LS measurements if TE measurements failed.
Methods:
In this prospective study, 292 participants (male:female, 189:103; median age, 60 years) with chronic liver disease (CLD) were enrolled. LS was measured via the consecutive use of conventional TE, 2D-SWE, and US-guided TE. The technical success rates and reliable LS measurement rates of the three elastography techniques were compared. The risk factors for TE failure were assessed through univariate and multivariate logistic regression models.
Results:
US-guided TE was associated with a higher technical success rate (281 of 292, 96.2%) and a higher reliable measurement rate (266 of 292, 91.1%) than conventional TE (technical success: 256 of 292, 87.7%; reliable measurements: 231 of 292, 79.1%; P<0.001 for both). In participants for whom conventional TE failed, 2D-SWE provided high rates of technical success (36 of 36, 100%) and reliable measurements (30 of 36, 83.3%). TE failure was associated with female sex (odds ratio [OR], 5.85; 95% confidence interval [CI], 1.30 to 26.40), severe reverberation artifacts (OR, 8.79; 95% CI, 3.93 to 19.69), and high skin-to-liver capsule depth (OR, 1.23; 95% CI, 1.09 to 1.39).
Conclusion
US guidance in TE improved the technical success and reliable measurement rates in the assessment of LS in patients with CLD. In participants for whom TE failed, subsequent 2D-SWE successfully delivered reliable LS measurements.