1.The vreference ranges and clinical usefulness of "free erythrocyte protoporphrin" test.
Jeong Ho KIM ; Q Eun PARK ; Oh Hun KWON
Korean Journal of Clinical Pathology 1993;13(1):13-18
No abstract available.
Erythrocytes*
2.The vreference ranges and clinical usefulness of "free erythrocyte protoporphrin" test.
Jeong Ho KIM ; Q Eun PARK ; Oh Hun KWON
Korean Journal of Clinical Pathology 1993;13(1):13-18
No abstract available.
Erythrocytes*
3.The vreference ranges and clinical usefulness of "free erythrocyte protoporphrin" test.
Jeong Ho KIM ; Q Eun PARK ; Oh Hun KWON
Korean Journal of Clinical Pathology 1992;12(1):13-18
No abstract available.
Erythrocytes*
4.Endotracheal Intubation in the Emergency Department of an Tertiary Care Center.
Byeong Cheol KIM ; Bo Seung KANG ; Hyoung Gon SONG ; Jeong Hun LEE ; Keun Jeong SONG ; Yeon Kwon JEONG
Journal of the Korean Society of Emergency Medicine 1999;10(4):579-586
BACKGROUND: The purpose of this study was to analyze the endotracheal intubation cases performed in the emergency department. METHODS: We investigated retrospectively 326 cases of endotracheal intubation performed in the emergency department of a tertiary care center from April 1, 1998 to March 31, 1999. We focused on operators, medications used, its success rate and immediate complications, and the relationship between its success rate and medications. RESULTS: Of 326 consecutive intubations, 193 patients(59.2%) were done by emergency medicine residents or attending physician. While 320 patients(98.2%) were successfully intubated, 6 patients could not be intubated and 2 patients underwent tracheostomy. Of 50 cases of intubations(15.3%) attempted with paralyzing agents, 48 cases were done with succinylcholine and 46 cases underwent by emergency physicians. Intubations with neuromuscular paralysis resulted in high success rates at the first attempt. Of 55 immediate adverse events were encountered in 47 patients(desaturation=17, bronchial intubation=15, hypotension=8, bradycardia=4, cardiac arrest=2, others=5). CONCLUSION: At this institution, paralyzing agents were used infrequently, but almost all of them were used by emergency physicians.
Emergencies*
;
Emergency Medicine
;
Emergency Service, Hospital*
;
Humans
;
Intubation
;
Intubation, Intratracheal*
;
Paralysis
;
Retrospective Studies
;
Succinylcholine
;
Tertiary Care Centers*
;
Tertiary Healthcare*
;
Tracheostomy
5.Determination of glygated hemoglobin by affinity chromatographymethod.
Myung Seo KANG ; Jeong Ho KIM ; Oh Hun KWON ; Samuel Y LEE
Korean Journal of Clinical Pathology 1991;11(2):363-367
No abstract available.
6.Evaluation of fructosamine tests and preanalytical errors.
Jeong Ho KIM ; Myung Seo KANG ; Oh Hun KWON ; Samuel Y LEE
Korean Journal of Clinical Pathology 1991;11(2):333-339
No abstract available.
Fructosamine*
7.The positional relationship between the mandible and the hyoid bone in mandibular protrusion after orthognathic surgery evaluated with 3-d ct.
Sang Han LEE ; Jeong Hun NAM ; Chang Wook JUNG ; Tae Geon KWON
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2003;29(3):173-181
PURPOSE: This study was intended to evaluate the positional relationship between the hyoid bone and the mandible in patients with mandibular protrusion after mandibular set-back surgery by means of 3D-CT. MATERIALS AND METHODS: Preoperative(3 weeks before) and postoperative (6 weeks after) 3D-CT and cephalogram were taken on 32 patients(12 male, 20 female, mean age of 23.2) treated by bilateral sagittal split osteotomy with rigid fixation. The angular measurement on 3D-CT basilar view were deviation of Me and H, long axis angle of left and right cornu majus. The lineal measurement on 3D-CT basilar view were composed of intercondylar line and coordinates(x,y) of Me and H. The angular and lineal measurement of lateral cephalogram were composed of mandibular plane angle, SNA, SNB, ANB, FH-NA and FH-NB, and coordinates(x,y) of B, Pog, Me and H, PAS, Lpw, MPH and IAS. On the frontal cephalogram, deviation of Me were evaluated. RESULTS: The mean mandibular set-back was 8.0mm horizontally and mandibular plane angle was slightly increased. The hyoid bone was displaced postero-inferiorly, the distance between MP(mandibular plane) and H(hyoid bone) was increased and the posterior airway space values (PAS, Lpw, IAS) were decreased. The coordinates Me(x,y), H(x,y) and deviation angle Me' and H'were revealed the strong positive correlation. CONCLUSION: The results revealed that the horizontal, vertical and transverse relationship of the mandibular and the hyoid bone movements were significantly correlated in patients performed mandibular set-back surgery.
Axis, Cervical Vertebra
;
Female
;
Humans
;
Hyoid Bone*
;
Male
;
Mandible*
;
Orthognathic Surgery*
;
Osteotomy
8.The characteristics of blood compinents from 400mL CPDA-1 wholeblood.
Q Eun PARK ; Hyun Ok KIM ; Yoon Jeong DOH ; Oh Hun KWON ; Young Chul OH
Korean Journal of Clinical Pathology 1993;13(1):115-120
No abstract available.
9.The characteristics of blood compinents from 400mL CPDA-1 wholeblood.
Q Eun PARK ; Hyun Ok KIM ; Yoon Jeong DOH ; Oh Hun KWON ; Young Chul OH
Korean Journal of Clinical Pathology 1992;12(1):115-120
No abstract available.
10.Comparison of Molecular Biologic Methods for Detecting HBV-DNA in the Sera which Showed Both Hepatitis B Surface Antigen and Antibody Positivity.
Mun Jeong KIM ; Hyon Suk KIM ; Oh Hun KWON ; Kwang Hyub HAHN
Korean Journal of Clinical Pathology 1997;17(6):1124-1136
BACKGROUND: Serologic markers are used to screen and diagnose the hepatitis B virus infection. In endemic area of hepatitis B, the coexistence of HBsAg and anti-HBs was frequently observed. This finding is unusual and difficult to interpret. In this study, we performed three molecular biologic assays-polymerase chain reaction (PCR), chemiluminescent molecular hybridization assay (CMHA), branched DNA (bDNA) nucleic acid hybridization assay- to detect HBV-DNA in the sera which showed both HBsAg and anti-HBs positivity. To define the patients` exact clinical conditions, we analysed the characteristics of the patients according to their diagnoses, other serologic markers and clinical findings. METHODS: HBsAg and anti-HBs were detected by EIA (Enzygnost, Behringwerke, Germany) from clinical specimens of Yonsei University College of Medicine Severance Hospital collected In the period between January 1996 and December 1996. Eighty three specimens from Severance Hospital and twenty two specimens from Health Care Center were randomly selected and were subjected to HBV PCR, HBV CMHA and HBV bDNA assay for the presence of HBV-DNA. RESULTS: The patients were arbitrarily divided into 4 groups on the basis of the optical density values of enzyme immunoassay results. Group I (high HBsAg and high antral-HBs) consisted of 6 cases; group II (high HBsAg and low anti-HBs) consisted of 70 cases, group III (low HBsAg and high anti-HBs) consisted of 1 case; group IV (low HBsAg and low antral-HBs) consisted of 6 cases. Among 83 cases, the positive rate was 51.8% (43 cases) using PCR method, 53.0% (44 cases) using CMHA, 60.2% (50 cases) using bDNA assay. HBeAg and anti-HBc IgM were helpful to predict the presence of HBV-DNA in the sera. CONCLUSIONS: More than half of the patients who showed both HBsAg and anti-HBs positivity were positive for HBV-DNA by molecular biologic methods. In contrast, no one whose serologic markers with only anti-HBc positivity with out HBsAg and anti-HBs positivity showed HBV-DNA positive in the sera from Health Care Center. Taken together, the management and follow-up of the patients of both HBsAg and anti-HBs positivity could be greatly aided by combined adoption of any one molecular biologic assay of HBY-DNA with other serologic markers such as HBeAg and anti-HBc IgM.
Biological Assay
;
Branched DNA Signal Amplification Assay
;
Delivery of Health Care
;
Diagnosis
;
DNA
;
Hepatitis B e Antigens
;
Hepatitis B Surface Antigens*
;
Hepatitis B virus
;
Hepatitis B*
;
Hepatitis*
;
Humans
;
Immunoenzyme Techniques
;
Immunoglobulin M
;
Nucleic Acid Hybridization
;
Polymerase Chain Reaction