1.The Efficacy of Cervical Pedicle Screw Is Enhanced When Used With 5.5-mm Rods for Metastatic Cervical Spinal Tumor Surgery
Danbi PARK ; Sang Hyub LEE ; Subum LEE ; Jemin PARK ; Hyeon Gyu YANG ; Chongman KIM ; Jin Hoon PARK
Neurospine 2024;21(1):352-360
Objective:
The cervical spine presents challenges in treating metastatic cervical spinal tumors (MCSTs). Although the efficacy of cervical pedicle screw placement (CPS) has been well established, its use in combination with 5.5-mm rods for MCST has not been reported. This study aimed to evaluate the efficacy of CPS combined with 5.5-mm rods in treating MCST and compare it with that of CPS combined with traditional 3.5-mm rods.
Methods:
This retrospective study analyzed 58 patients with MCST who underwent posterior cervical spinal fusion surgery by a single surgeon between March 2012 and December 2022. Data included demographics, surgical details, imaging results, numerical rating scale score for neck pain, Eastern Cooperative Oncology Group performance status, and Spine Oncology Study Group Outcomes Questionnaire responses.
Results:
Preoperative Spinal Instability Neoplastic Scores were significantly higher in the 5.5-mm rod group. Greater kyphotic changes in the index vertebra were observed in the 3.5-mm rod group. Neck pain reduction was significantly better in the 5.5-mm rod group.
Conclusion
CPS with 5.5-mm rods provides superior biomechanical stability and effectively resists forward bending momentum in posterior MCST fusion surgery. These findings support the use of 5.5-mm rods to enhance surgical outcomes.
2.The Efficacy of Cervical Pedicle Screw Is Enhanced When Used With 5.5-mm Rods for Metastatic Cervical Spinal Tumor Surgery
Danbi PARK ; Sang Hyub LEE ; Subum LEE ; Jemin PARK ; Hyeon Gyu YANG ; Chongman KIM ; Jin Hoon PARK
Neurospine 2024;21(1):352-360
Objective:
The cervical spine presents challenges in treating metastatic cervical spinal tumors (MCSTs). Although the efficacy of cervical pedicle screw placement (CPS) has been well established, its use in combination with 5.5-mm rods for MCST has not been reported. This study aimed to evaluate the efficacy of CPS combined with 5.5-mm rods in treating MCST and compare it with that of CPS combined with traditional 3.5-mm rods.
Methods:
This retrospective study analyzed 58 patients with MCST who underwent posterior cervical spinal fusion surgery by a single surgeon between March 2012 and December 2022. Data included demographics, surgical details, imaging results, numerical rating scale score for neck pain, Eastern Cooperative Oncology Group performance status, and Spine Oncology Study Group Outcomes Questionnaire responses.
Results:
Preoperative Spinal Instability Neoplastic Scores were significantly higher in the 5.5-mm rod group. Greater kyphotic changes in the index vertebra were observed in the 3.5-mm rod group. Neck pain reduction was significantly better in the 5.5-mm rod group.
Conclusion
CPS with 5.5-mm rods provides superior biomechanical stability and effectively resists forward bending momentum in posterior MCST fusion surgery. These findings support the use of 5.5-mm rods to enhance surgical outcomes.
3.The Efficacy of Cervical Pedicle Screw Is Enhanced When Used With 5.5-mm Rods for Metastatic Cervical Spinal Tumor Surgery
Danbi PARK ; Sang Hyub LEE ; Subum LEE ; Jemin PARK ; Hyeon Gyu YANG ; Chongman KIM ; Jin Hoon PARK
Neurospine 2024;21(1):352-360
Objective:
The cervical spine presents challenges in treating metastatic cervical spinal tumors (MCSTs). Although the efficacy of cervical pedicle screw placement (CPS) has been well established, its use in combination with 5.5-mm rods for MCST has not been reported. This study aimed to evaluate the efficacy of CPS combined with 5.5-mm rods in treating MCST and compare it with that of CPS combined with traditional 3.5-mm rods.
Methods:
This retrospective study analyzed 58 patients with MCST who underwent posterior cervical spinal fusion surgery by a single surgeon between March 2012 and December 2022. Data included demographics, surgical details, imaging results, numerical rating scale score for neck pain, Eastern Cooperative Oncology Group performance status, and Spine Oncology Study Group Outcomes Questionnaire responses.
Results:
Preoperative Spinal Instability Neoplastic Scores were significantly higher in the 5.5-mm rod group. Greater kyphotic changes in the index vertebra were observed in the 3.5-mm rod group. Neck pain reduction was significantly better in the 5.5-mm rod group.
Conclusion
CPS with 5.5-mm rods provides superior biomechanical stability and effectively resists forward bending momentum in posterior MCST fusion surgery. These findings support the use of 5.5-mm rods to enhance surgical outcomes.
4.The Efficacy of Cervical Pedicle Screw Is Enhanced When Used With 5.5-mm Rods for Metastatic Cervical Spinal Tumor Surgery
Danbi PARK ; Sang Hyub LEE ; Subum LEE ; Jemin PARK ; Hyeon Gyu YANG ; Chongman KIM ; Jin Hoon PARK
Neurospine 2024;21(1):352-360
Objective:
The cervical spine presents challenges in treating metastatic cervical spinal tumors (MCSTs). Although the efficacy of cervical pedicle screw placement (CPS) has been well established, its use in combination with 5.5-mm rods for MCST has not been reported. This study aimed to evaluate the efficacy of CPS combined with 5.5-mm rods in treating MCST and compare it with that of CPS combined with traditional 3.5-mm rods.
Methods:
This retrospective study analyzed 58 patients with MCST who underwent posterior cervical spinal fusion surgery by a single surgeon between March 2012 and December 2022. Data included demographics, surgical details, imaging results, numerical rating scale score for neck pain, Eastern Cooperative Oncology Group performance status, and Spine Oncology Study Group Outcomes Questionnaire responses.
Results:
Preoperative Spinal Instability Neoplastic Scores were significantly higher in the 5.5-mm rod group. Greater kyphotic changes in the index vertebra were observed in the 3.5-mm rod group. Neck pain reduction was significantly better in the 5.5-mm rod group.
Conclusion
CPS with 5.5-mm rods provides superior biomechanical stability and effectively resists forward bending momentum in posterior MCST fusion surgery. These findings support the use of 5.5-mm rods to enhance surgical outcomes.
5.The Efficacy of Cervical Pedicle Screw Is Enhanced When Used With 5.5-mm Rods for Metastatic Cervical Spinal Tumor Surgery
Danbi PARK ; Sang Hyub LEE ; Subum LEE ; Jemin PARK ; Hyeon Gyu YANG ; Chongman KIM ; Jin Hoon PARK
Neurospine 2024;21(1):352-360
Objective:
The cervical spine presents challenges in treating metastatic cervical spinal tumors (MCSTs). Although the efficacy of cervical pedicle screw placement (CPS) has been well established, its use in combination with 5.5-mm rods for MCST has not been reported. This study aimed to evaluate the efficacy of CPS combined with 5.5-mm rods in treating MCST and compare it with that of CPS combined with traditional 3.5-mm rods.
Methods:
This retrospective study analyzed 58 patients with MCST who underwent posterior cervical spinal fusion surgery by a single surgeon between March 2012 and December 2022. Data included demographics, surgical details, imaging results, numerical rating scale score for neck pain, Eastern Cooperative Oncology Group performance status, and Spine Oncology Study Group Outcomes Questionnaire responses.
Results:
Preoperative Spinal Instability Neoplastic Scores were significantly higher in the 5.5-mm rod group. Greater kyphotic changes in the index vertebra were observed in the 3.5-mm rod group. Neck pain reduction was significantly better in the 5.5-mm rod group.
Conclusion
CPS with 5.5-mm rods provides superior biomechanical stability and effectively resists forward bending momentum in posterior MCST fusion surgery. These findings support the use of 5.5-mm rods to enhance surgical outcomes.
6.Decreased Hippocampal Metabolism in Amnestic Mild Cognitive Impairment: Positron Emission Tomography Study
Chan hum PARK ; Young Min LEE ; JeMin PARK ; Byung Dae LEE ; EunSoo MOON ; Hee Jeong JEONG ; Soo Yeon KIM ; Kang Yoon LEE ; Hwagyu SUH ; Hye Kyung PARK ; Hak-Jin KIM ; Kyoungjune PARK ; Chi-Woong MUN ; Young-In CHUNG
Journal of Korean Geriatric Psychiatry 2020;24(1):37-41
Objective:
Little is known about factors influencing of hippocampal metabolism (HM) in mild cognitive impairment (MCI). Our objective was to determine whether HM in patients with amnestic MCI (aMCI) is decreased than non-amnestic MCI (naMCI).
Methods:
Overall, 32 MCI patients underwent 18F-fluorodeoxyglucose-positron emission tomography. They were characterized as aMCI (n=18) or naMCI (n=14) according to comprehensive neuropsychological criteria. Analysis of variances were used to assess differences on HM between aMCI and naMCI after controlling age, sex, education and Korean version of Mini Mental Status Examination.
Results:
We found that HM was more decreased in aMCI than naMCI. This result was not changed after controlling hippocampal volume.
Conclusion
Our findings suggest that aMCI is associated with decreased HM in MCI.