1.A clinical application study of digital manufacturing simple intraoral Gothic arch-tracing device in determining the centric relation of complete dentures.
Tuan Feng ZHOU ; Xue YANG ; Rui Jie WANG ; Ming Xuan CHENG ; Hua ZHANG ; Jin Qi WEI
Journal of Peking University(Health Sciences) 2023;55(1):101-107
OBJECTIVE:
To verify the consistency between the digital manufacturing simple intraoral Gothic arch-tracing device and the traditional intraoral Gothic arch-tracing device in determining the centric relation of complete dentures restoration.
METHODS:
Ten outpatients with edentulous jaws were selec-ted, and the centric relation of the patients was determined by digital manufacturing of simple intraoral Gothic arch-tracing device (T1) and traditional intraoral Gothic arch-tracing device (T2); the difference of clinical operation time between the two methods was recorded; the upper and lower edentulous jaw plaster models were scanned with two kinds of centric relation, the Standard Triangle Language (STL) files imported into Geomagic studio software to apply the best fitting of multiple points of the both upper jaw models, the fitted STL files imported into the 3 shape viewer software, and the maximum position deviations of the vertical, labial (buccal) and lingual directions of the mandibular midline area and molar areas in T1 and T2 groups measured. During the clinical complete dentures try-in, we observed whether there was midline deviation in the mouth of T1 group and T2 group, and whether the occlusion of posterior teeth was stable or not.
RESULTS:
The mean time spent on determining the centric relation of T1 and T2 groups was (41.90±2.64) min, (57.50±2.37) min respectively. Paired t test was conducted in the two groups, P < 0.01 with significant statistical difference; The mean maximum position deviation between T1 group and T2 group of the midline mandibular region in labial lingual direction was (0.32±0.14) mm, that was (0.40±0.23) mm in vertical direction; the mean maximum position deviation of molar area in buccal lingual direction was (0.35±0.23) mm and that was (0.33±0.20) mm in vertical direction. In the vertical and horizontal directions, the maximum position deviation of mandibles between group T1 and group T2 was controlled within 0.5 mm. In the process of clinical complete dentures try-in, there was no deviation from the center line of dentures. There was not warping, swinging and other poor stability phenomena in T1 and T2 groups.
CONCLUSION
The digital manufacturing of simple intraoral Gothic arch-tracing device can be used to determine the centric relation of complete dentures, which can not only save time of clinical operation, but also ensure the accuracy of the centric relation.
Humans
;
Centric Relation
;
Jaw Relation Record/methods*
;
Denture, Complete
;
Mouth, Edentulous
;
Jaw, Edentulous
2.Stability of phonetics to determine the horizontal jaw relation in healthy adults.
Xixi ZHANG ; Jianzhang LIU ; Jian-guo TAN ; Yang YANG ; Jun XU
West China Journal of Stomatology 2015;33(5):488-491
OBJECTIVEThe aim of this study was to compare the mandibular position when speaking with the intercuspal position and to check the stability of phonetics when determining the horizontal jaw relation in healthy adults.
METHODSA total of 19 healthy volunteers were recruited. Seven Chinese letters, namely, /xi/, /er/, /yi/, /ci/, /mi/, /ni/, and /ri/, were chosen in the test. O-bite was used to record the mandibular position when speaking these letters. A full-adjusted articulator was used to find the mandibular position during speech, and the mandibular position was measured using a vernier caliper. The mandibular position during speech with intercuspal position was compared in both anterior-posterior and left-right directions of the horizontal plane. Multi-factor analysis of variance was conducted for the statistical analysis of the effect of objects and letters on the mandibular position.
RESULTS1) The mandibular position was in front of the intercuspal occlusion position when speaking all seven letters, and almost no deviation was observed in the left and right directions (the mandibular position value of 82% was in the range of 0.5 mm). 2) Different objects had different mandibular positions during speech, whereas different letters did not. The distance between the centric relation position and the intercuspal position had a positive correlation with the range of the mandibular position during speech.
CONCLUSIONThe mandibular position was in front of the intercuspal position when speaking all seven words in the test. In the same object, the mandibular position was stable during speech.
Adult ; Centric Relation ; Dental Articulators ; Dental Occlusion ; Humans ; Jaw Relation Record ; Mandible ; Phonetics ; Speech
3.The effect of CR-CO discrepancy on cephalometric measurements in Class III malocclusion patients.
Yang Soo PARK ; Jong Chul KIM ; Hyeon Shik HWANG
Korean Journal of Orthodontics 1996;26(3):255-266
The purpose of this study was to investigate if there were a significant difference between cephalometric measurements of mandibular position derived from a centric occlusion tracing compared to those of a converted centric relation tracing in the Class III malocclusion. The sample consisted of 25 Class III malocclusion and 25 normal occlusion persons who had no orthodontic treatment. The records included an lateral cephalometrics in centric occlusion, centric relation and centric occlusion bite registration and diagnostic casts mounted on the SAM II articulator in CR. The amount of CR-CO discrepancy of condyle was recorded using a MPI(Mandibular Position Indicator, MPI 200(R), Great Lakes Orthodontics, USA). The conversion of the CO cephalograrn to CR using the MPI readings was performed on the Conversion work sheet. Measures of mandibular position were chosen for the purpose of this study. The comparison of the difference between CO and CR cephalometric measurements in the normal occlusion and Class III malocclusion group were studied. The results were as follows: 1. In the features of CR-CO discrepancy of the condyle, the condyle was displaced posterior and inferior when the teeth were in centric occlusion. The horizontal component(deltaX) in Class III malocclusion group was greater than the vertical component(deltaZ) and also greater than the horizontal component(deltaX) in normal occlusion group. There was no statistically significant correlation between MPI measurements and the groups of normal occlusion and Class III malocclusion group. 2. In the comparison of the cephalometric measurements in each group, Normal occlusion group showed significant difference in measurements such as ANB, Facial angle, Facial convexity and ODI. Class III malocclusion group showed significant difference in measurements such as ANB, Facial angle, Facial convexity, ODI, SNB, APDI, L1-FP and it had more significance than the normal occlusion group. 3. The Value of cephalometric measurements was significantly different between CO and CR but there were no differences between the groups of normal occlusion and Class III malocclusion. The results of this study suggest that if the discrepancies are greater than the amount of normal displacement from clinically captured centric relation, centric relation should be considered as the starting point for proper diagnosis and treatment planning.
Centric Relation
;
Dental Articulators
;
Diagnosis
;
Humans
;
Jaw Relation Record
;
Lakes
;
Malocclusion*
;
Orthodontics
;
Reading
;
Tooth
4.Relationship between CO-CR discrepancy and facial skeletal type.
Jin Young CHO ; Young Jun LEE ; Young Guk PARK ; Kyu Rhim CHUNG
Korean Journal of Orthodontics 1998;28(5):839-853
The present study was performed to prove the relationship between CO-CR discrepancy and facial skeletal type. In this study, 242 subjects were randomly selected and devided into 9 groups(devided into class I, Il, 111 by ANB and each one devided into dolicho-, brachy mesofacial skeleton by Ricketts' vertical index). Lateral cephalometric radiographs with the mandible in centric occlusion were taken and measured and CO and CR bites were registered on all subjects. Diagnostic casts were mounted on Panadent articulator using an estimated face-bow and centric relation bite registration. The amount and direction of CO-CR discrepancy present was recorded using a Condylar Position Indicator(CPI) and a centric occlusion wax bite registration. CPI measurements and cephalometric measurements were statistically analyzed. The finding of this study can be summerized as follows: 1. There is little correlation between right and left sides for magnitude or direction. of CO-CR discrepancies. The correlation between the magnitude of CO-CR discrepancy of left A-P and right A-P is higher than that of left S-I and right S-I. 2. Correlation of Class H malocclusion group was higher than that of the other groups between the magnitude of CO-CR discrepancy of left CPI and right CPL 3. There is no difference between the pattern of CO-CR discrepancy of 9 malocclusion groups. 4. There is very little, if any, correlation between Skeletofacial measurements and CO-CR discrepancy. 5. In Class II brachyfacial skeleton and Class IIl mesofacial skeleton there was Lateral cephalometric measurements by that we predict CPI measurements was detected. That was overbite, overjet, upper gonial angle, lower gonial angle, saddle angle, articular angle, convexity of point A, ANS-Me/Na-Me, PCBL/I3H, Posterior FH/anterior FR
Centric Relation
;
Dental Articulators
;
Jaw Relation Record
;
Malocclusion
;
Mandible
;
Overbite
;
Skeleton
5.Reproducibility of centric relation of the patient with severe dental attrition for oral rehabilitation.
Hong KANG ; Yonglie CHAO ; Xinzhu YI
West China Journal of Stomatology 2003;21(6):457-459
OBJECTIVEStandards for determining mandibular position, especially the centric relation (CR), are in controversy because of anatomical, neurophysiological factors and research methods or instrument. The purpose of this study was to reevaluate the reproducibility of centric relation of the patients with severe dental attrition for oral rehabilitation.
METHODSReproducibility of the centric relation of 6 patients with severe occlusal attrition was investigated by using D5A Denar fully adjustable articulator and the Pantronic recording system.
RESULTS1. In supine position, anterior-posterior(AP) displacement of centric relation (CR) was 0.14 mm and superior-inferior(SI) displacements of CR were between 0.11 mm-0.12 mm. 2. In upright position, anterior-posterior displacement of CR was 0.35 mm and superior-inferior changes of CR were between 0.13 mm-0.20 mm.
CONCLUSIONThe CR is the most stable and reproducible position of mandibule in normal stomatological system and is useful as a reference position in occlusal treatment and functional rehabilitation.
Aged ; Centric Relation ; Dental Occlusion, Centric ; Female ; Humans ; Jaw Relation Record ; instrumentation ; Male ; Mandibular Condyle ; physiopathology ; Middle Aged ; Movement ; Reproducibility of Results ; Tooth Attrition ; rehabilitation ; therapy
6.The treatment of an edentulous patient with DENTCA(TM) CAD/CAM Denture.
Joon Ho PARK ; In Ho CHO ; Soo Yeon SHIN ; Yu Sung CHOI
The Journal of Korean Academy of Prosthodontics 2015;53(1):19-25
Nowadays, CAD/CAM is broadly used in dentistry for inlays, crowns, implant abutments and its spectrum is expanding to complete dentures. Utilizing CAD/CAM to fabricate complete dentures is expected to decrease chair time and the number of visits, thus decreasing total fabrication time, expenses and errors caused during fabrication processes. One of the systems using CAD/CAM, DENTCA(TM) CAD/CAM denture (DENTCA Inc. Los Angeles, USA) scans edentulous impressions, designs dentures digitally, fabricates try-in dentures by 3D printing and converts them into final dentures. Patients can wear final dentures after only 2 - 3 visits with satisfying adaptation. This case report introduces a 71-year-old male patient who visited to consult remaking of existing old dentures. Residual teeth with bad prognosis and root remnants were extracted and the patient used reformed existing mandibular denture for 2 months. And then DENTCA system started. One-step border molding was done using conventional tray of adequate size provided by DENTCA system and wash impression was taken. Gothic arch tracing was completed based on the vertical dimension of existing dentures. Both maxillary and mandibular trays were placed to the resultant centric relation and bite registration was taken. Then DENTCA scanned the bite registration, arranged the teeth, completed the festooning and fabricated the try-in dentures by 3D printing. The try-in dentures were positioned, occlusal plane and occlusal relations were evaluated. The try-in dentures were converted to final dentures. To create bilateral balanced occlusion, occlusal adjustment was done after clinical remounting using facebow transfer. The result was satisfactory and it was confirmed by patient and operator.
Aged
;
Centric Relation
;
Crowns
;
Dental Occlusion
;
Dentistry
;
Denture, Complete
;
Dentures*
;
Fungi
;
Humans
;
Inlays
;
Jaw Relation Record
;
Male
;
Occlusal Adjustment
;
Prognosis
;
Tooth
;
Vertical Dimension
7.Evaluation of mechanical and projective standardization in digital subtraction radiography.
Bong In CHOI ; Bong Hae CHO ; Kyung Soo NAH
Journal of Korean Academy of Oral and Maxillofacial Radiology 1998;28(1):215-224
The following conclusions were obtained from the non-reconstructed and reconstructed subtraction images of the standard intraoral radiographs which were taken with paralleing technique with Rinn XCP only and with occlusal bite registration for geometric standardization using bilateral mandibular premolar and molar regions of two dry humad skulls. 1. The SD of the overall subtraction images of the premolars and molars of the non-reconstructed, tnat is, the manual superimposition showed statistically significant difference between the non-registered and registered groups. 2. In non-reconstructed and non-registered cases, the quality of the subtraction images were improved when superimposition was focally done and this was more evident in areas where the radiographic imaged tend to be distorted due to anatomic readons. 3. In non-restructed and registered cases, the subtraction images were consistent regardless of the anatomic site or the focus superimposition. This means that the geometric standardization with only occlusal bite registration could produce serial radiographs which is suitable for subtraction. 4. The SD of the overall subtraction images of the premolars and molars of the reconstructed, that is, the automatic superimposition showed statistically insignificant difference between the non-registered and registered groups. This means that using reconstruction, subtraction radiography is possible without occlusal bite registration. 5. In reconstructed and non-registered cases, compatible quality of the subtraction images were obtained regardless of the anatomic site or area of the corresponding points. 6. In reconstructed and registered cases, best subtraction images whose quality showed sensitivity to the areas of corresponding points were obtained.
Bicuspid
;
Jaw Relation Record
;
Molar
;
Radiography*
;
Skull
8.A STUDY ON THE ACCURACY OF THE IMPRESSION BODY ACCORDING TO MATERIALS AND FORMS OF THE INDIVIDUAL TOOTH TRAY.
Duck Woo RYU ; Ju Hwan LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 2000;38(2):242-254
Accurate impression is very important to achieve desirable prosthesis and there are many factors in taking a good impression. For example, types of impression material, types of impression tray, impression taking methods and so on. Recently individual tooth tray technique is accepted as obtaining good impression that can be applied to multiple abutment impression, heavy salivated patient, to minimize the effect of natural teeth' s undercuts and to reduce pain during cord packing procedures. The purpose of this study was to compare the accuracy according to materials and forms of the individual tooth tray which is clinically applied nowadays. Used materials in experiment were divided into 3 types (acrylic resin, Futar' occlusion, Blu-mousse) and forms were divided into 2 types (forming occlusal vent hole or not and forming marginal vent space or not). Stone master model from impression body and metal master model were measured by X-PLAN360d to compare occlusal surface discrepancy and marginal discrepancy. The results were as follows 1. In comparison of occlusal surface discrepancy and marginal discrepancy according to materials, groups with three materials showed no statistical difference. 2. In comparison of occlusal surface discrepancy and marginal discrepancy according to occlusal vent hole, groups with occlusal vent hole showed significantly less marginal discrepancy than groups with no occlusal vent hole(p<0.05). 3. In comparison of occlusal surface discrepancy and marginal discrepancy according to 0.5mm marginal-vent-space, groups with no 0.5mm-marginal-vent-space showed significantly less mar ginal discrepancy than groups with 0.5mm-marginal-vent-space(p<0.05). In summary, these results suggest that individual tooth tray made of 3 types of materials with occlusal vent hole and individual tooth tray made of acrylic resin with no marginal vent space showed good accuracy of impression. In addition, individual tooth tray which is made of bite registration materials may be more useful because of advantage in facility and timesaving aspect of fabrication.
Humans
;
Jaw Relation Record
;
Prostheses and Implants
;
Tooth*
9.A STUDY ON THE ACCURACY OF THE IMPRESSION BODY ACCORDING TO MATERIALS AND FORMS OF THE INDIVIDUAL TOOTH TRAY.
Duck Woo RYU ; Ju Hwan LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 2000;38(2):242-254
Accurate impression is very important to achieve desirable prosthesis and there are many factors in taking a good impression. For example, types of impression material, types of impression tray, impression taking methods and so on. Recently individual tooth tray technique is accepted as obtaining good impression that can be applied to multiple abutment impression, heavy salivated patient, to minimize the effect of natural teeth' s undercuts and to reduce pain during cord packing procedures. The purpose of this study was to compare the accuracy according to materials and forms of the individual tooth tray which is clinically applied nowadays. Used materials in experiment were divided into 3 types (acrylic resin, Futar' occlusion, Blu-mousse) and forms were divided into 2 types (forming occlusal vent hole or not and forming marginal vent space or not). Stone master model from impression body and metal master model were measured by X-PLAN360d to compare occlusal surface discrepancy and marginal discrepancy. The results were as follows 1. In comparison of occlusal surface discrepancy and marginal discrepancy according to materials, groups with three materials showed no statistical difference. 2. In comparison of occlusal surface discrepancy and marginal discrepancy according to occlusal vent hole, groups with occlusal vent hole showed significantly less marginal discrepancy than groups with no occlusal vent hole(p<0.05). 3. In comparison of occlusal surface discrepancy and marginal discrepancy according to 0.5mm marginal-vent-space, groups with no 0.5mm-marginal-vent-space showed significantly less mar ginal discrepancy than groups with 0.5mm-marginal-vent-space(p<0.05). In summary, these results suggest that individual tooth tray made of 3 types of materials with occlusal vent hole and individual tooth tray made of acrylic resin with no marginal vent space showed good accuracy of impression. In addition, individual tooth tray which is made of bite registration materials may be more useful because of advantage in facility and timesaving aspect of fabrication.
Humans
;
Jaw Relation Record
;
Prostheses and Implants
;
Tooth*
10.Accuracy comparison of buccal bite scans by five intra-oral scanners
Ji Man PARK ; Jin JEON ; Seong Joo HEO
Journal of Dental Rehabilitation and Applied Science 2018;34(1):17-31
PURPOSE: The purpose of this study was to investigate the accuracy of the interocclusal relationship between upper and lower teeth according to the buccal interocclusal record scan using various intraoral scanner systems. MATERIALS AND METHODS: The upper and lower full arch Models with normal occlusion were scanned with 5 intraoral scanners (Cerec Omnicam, CS3500, iTero, Trios, True Definition). Buccal interocclusal record scan was taken only at the left side while occlusion was intentionally raised by 1 mm, 2 mm, 3 mm, and 4 mm with metal cylinder core embedded within polyvinylsiloxane bite registration material at the right molar region. The superimposition analysis was done to evaluate overall three-dimensional deviation and cross-section analysis was done to evaluate the degree and the direction of deviation of interocclusal relationship. RESULTS: From the superimposition study, Cerec Omnicam showed the least deviation (165.5 µm) and CS3500 (369.0 µm) showed the largest (P < 0.01). And the deviation was greater in 3, 4, 2 mm group than 1 mm (P < 0.01). From the cross-section study, Cerec Omnicam showed the farthest deviation (−242.8 µm) and CS3500 showed the closest deviation (312.5 µm) and a significantly high value was shown in 3 mm group. CONCLUSION: Every intraoral scanner has different accuracy in reproducing interocclusal relationship.
Intention
;
Jaw Relation Record
;
Molar
;
Tooth