1.Safety and Efficacy of Adalimumab for Patients With Moderate to Severe Crohn's Disease: The Taiwan Society of Inflammatory Bowel Disease (TSIBD) Study.
Chen Wang CHANG ; Shu Chen WEI ; Jen Wei CHOU ; Tzu Chi HSU ; Chiao Hsiung CHUANG ; Ching Pin LIN ; Wen Hung HSU ; Hsu Heng YEN ; Jen Kou LIN ; Yi Jen FANG ; Horng Yuan WANG ; Hung Hsin LIN ; Deng Cheng WU ; Yen Hsuan NI ; Cheng Yi WANG ; Jau Min WONG
Intestinal Research 2014;12(4):287-292
BACKGROUND/AIMS: Only moderate to severe Crohn's Disease (CD) patients without a satisfactory conventional therapy effect are eligible to get reimbursement from the National Health Insurance of Taiwan for using adalimumab. These are more stringent criteria than in many Western countries and Japan and Korea. We aim to explore the efficacy of using adalimumab in CD patients under such stringent criteria. METHODS: A retrospective analysis was conducted in nine medical centers in Taiwan and we collected the results of CD patients receiving adalimumab from Sep 2009 to Mar 2014. The clinical characteristics, response measured by CDAI (Crohn's Disease Activity Index), adverse events and survival status were recorded and analyzed. CR-70, CR-100, and CR-150 were defined as attaining a CDAI decrease of 70, 100 or 150 points compared with baseline. RESULTS: A total of 103 CD patient records were used in this study. Sixty percent of these patients received combination therapy of adalimumab together with immunomodulators. CR-70 was 68.7%, 74.5% and 88.4% after week 4, 8 and 12 of treatment, respectively. The steroid-free rate, complications and survival were 47.6%, 9.7% and 99% of patients, respectively. In considering the mucosal healing, only 25% patients achieve mucosal healing after treatment for 6 to12 months. Surgery was still needed in 16.5% of patients. Combination treatment of adalimumab with immunomodulators further decreased the level of CDAI at week 8 when compared with the monotherapy. CONCLUSIONS: Even under the stringent criteria for using adalimumab, the response rate was comparable to those without stringent criteria.
Adalimumab
;
Crohn Disease*
;
Humans
;
Immunologic Factors
;
Inflammatory Bowel Diseases*
;
Japan
;
Korea
;
National Health Programs
;
Retrospective Studies
;
Taiwan*
2.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
3.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
4.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
5.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
6.The Quantitative Evaluation of Automatic Segmentation in Lumbar Magnetic Resonance Images
Yao-Wen LIANG ; Yu-Ting FANG ; Ting-Chun LIN ; Cheng-Ru YANG ; Chih-Chang CHANG ; Hsuan-Kan CHANG ; Chin-Chu KO ; Tsung-Hsi TU ; Li-Yu FAY ; Jau-Ching WU ; Wen-Cheng HUANG ; Hsiang-Wei HU ; You-Yin CHEN ; Chao-Hung KUO
Neurospine 2024;21(2):665-675
Objective:
This study aims to overcome challenges in lumbar spine imaging, particularly lumbar spinal stenosis, by developing an automated segmentation model using advanced techniques. Traditional manual measurement and lesion detection methods are limited by subjectivity and inefficiency. The objective is to create an accurate and automated segmentation model that identifies anatomical structures in lumbar spine magnetic resonance imaging scans.
Methods:
Leveraging a dataset of 539 lumbar spinal stenosis patients, the study utilizes the residual U-Net for semantic segmentation in sagittal and axial lumbar spine magnetic resonance images. The model, trained to recognize specific tissue categories, employs a geometry algorithm for anatomical structure quantification. Validation metrics, like Intersection over Union (IOU) and Dice coefficients, validate the residual U-Net’s segmentation accuracy. A novel rotation matrix approach is introduced for detecting bulging discs, assessing dural sac compression, and measuring yellow ligament thickness.
Results:
The residual U-Net achieves high precision in segmenting lumbar spine structures, with mean IOU values ranging from 0.82 to 0.93 across various tissue categories and views. The automated quantification system provides measurements for intervertebral disc dimensions, dural sac diameter, yellow ligament thickness, and disc hydration. Consistency between training and testing datasets assures the robustness of automated measurements.
Conclusion
Automated lumbar spine segmentation with residual U-Net and deep learning exhibits high precision in identifying anatomical structures, facilitating efficient quantification in lumbar spinal stenosis cases. The introduction of a rotation matrix enhances lesion detection, promising improved diagnostic accuracy, and supporting treatment decisions for lumbar spinal stenosis patients.
7.Management of ulcerative colitis in Taiwan: consensus guideline of the Taiwan Society of Inflammatory Bowel Disease updated in 2023
Hsu-Heng YEN ; Jia-Feng WU ; Horng-Yuan WANG ; Ting-An CHANG ; Chung-Hsin CHANG ; Chen-Wang CHANG ; Te-Hsin CHAO ; Jen-Wei CHOU ; Yenn-Hwei CHOU ; Chiao-Hsiung CHUANG ; Wen-Hung HSU ; Tzu-Chi HSU ; Tien-Yu HUANG ; Tsung-I HUNG ; Puo-Hsien LE ; Chun-Che LIN ; Chun-Chi LIN ; Ching-Pin LIN ; Jen-Kou LIN ; Wei-Chen LIN ; Yen-Hsuan NI ; Ming-Jium SHIEH ; I-Lun SHIH ; Chia-Tung SHUN ; Tzung-Jiun TSAI ; Cheng-Yi WANG ; Meng-Tzu WENG ; Jau-Min WONG ; Deng-Chyang WU ; Shu-Chen WEI
Intestinal Research 2024;22(3):213-249
Ulcerative colitis (UC) is a chronic inflammation of the gastrointestinal tract and is characterized by alternating periods of inflammation and remission. Although UC incidence is lower in Taiwan than in Western countries, its impact remains considerable, demanding updated guidelines for addressing local healthcare challenges and patient needs. The revised guidelines employ international standards and recent research, emphasizing practical implementation within the Taiwanese healthcare system. Since the inception of the guidelines in 2017, the Taiwan Society of Inflammatory Bowel Disease has acknowledged the need for ongoing revisions to incorporate emerging therapeutic options and evolving disease management practices. This updated guideline aims to align UC management with local contexts, ensuring comprehensive and context-specific recommendations, thereby raising the standard of care for UC patients in Taiwan. By adapting and optimizing international protocols for local relevance, these efforts seek to enhance health outcomes for patients with UC.
8.Management of Crohn’s disease in Taiwan: consensus guideline of the Taiwan Society of Inflammatory Bowel Disease updated in 2023
Jia-Feng WU ; Hsu-Heng YEN ; Horng-Yuan WANG ; Ting-An CHANG ; Chung-Hsin CHANG ; Chen-Wang CHANG ; Te-Hsin CHAO ; Jen-Wei CHOU ; Yenn-Hwei CHOU ; Chiao-Hsiung CHUANG ; Wen-Hung HSU ; Tzu-Chi HSU ; Tien-Yu HUANG ; Tsung-I HUNG ; Puo-Hsien LE ; Chun-Che LIN ; Chun-Chi LIN ; Ching-Pin LIN ; Jen-Kou LIN ; Wei-Chen LIN ; Yen-Hsuan NI ; Ming-Jium SHIEH ; I-Lun SHIH ; Chia-Tung SHUN ; Tzung-Jiun TSAI ; Cheng-Yi WANG ; Meng-Tzu WENG ; Jau-Min WONG ; Deng-Chyang WU ; Shu-Chen WEI
Intestinal Research 2024;22(3):250-285
Crohn’s disease (CD) is a chronic, fluctuating inflammatory condition that primarily affects the gastrointestinal tract. Although the incidence of CD in Taiwan is lower than that in Western countries, the severity of CD presentation appears to be similar between Asia and the West. This observation indicates the urgency for devising revised guidelines tailored to the unique reimbursement system, and patient requirements in Taiwan. The core objectives of these updated guidelines include the updated treatment choices and the integration of the treat-to-target strategy into CD management, promoting the achievement of deep remission to mitigate complications and enhance the overall quality of life. Given the diversity in disease prevalence, severity, insurance policies, and access to medical treatments in Taiwan, a customized approach is imperative for formulating these guidelines. Such tailored strategies ensure that international standards are not only adapted but also optimized to local contexts. Since the inception of its initial guidelines in 2017, the Taiwan Society of Inflammatory Bowel Disease (TSIBD) has acknowledged the importance of continuous revisions for incorporating new therapeutic options and evolving disease management practices. The latest update leverages international standards and recent research findings focused on practical implementation within the Taiwanese healthcare system.