1.Evaluation of Spontaneous Intracranial Hypotension Using Radionuclide Cisternography.
Chan H PARK ; Seok Nam YOON ; Moonsun PAI ; Suzy KIM ; Yunmin OH ; Jangsung KIM
Korean Journal of Nuclear Medicine 1999;33(2):178-183
We report four cases of spontaneous intracranial hypotension that were investigated by radionuclide cisternography Tc-99m-diethylenetriamine pentaacetic acid radionuclide cisternography of all our patients showed direct sign of cerebrospinal fluid leakage as well as indirect signs of less activity than expected over the cerebral convexities and rapid appearance of bladder activity. The headache of all patients was eventually controlled with bed rest and hydration.
Bed Rest
;
Cerebrospinal Fluid
;
Headache
;
Humans
;
Intracranial Hypotension*
;
Urinary Bladder
2.A Shotgun Injury with Billiard Ball Ricochet Effect: A Case Report.
Jeong Woo PARK ; Cheol Ho CHOI ; Joon Ho LEE ; Whee Yeol CHO ; Youn Shin KIM ; Han Young LEE
Korean Journal of Legal Medicine 2009;33(2):122-125
Because of the strict gun control system in Korea, deaths from gunfire injury cannot be frequently seen in the legal autopsies. Injuries or deaths among the registered hunters using shotguns, though not common, have been reported via mass media. We experienced a 52-year-old male's shotgun death in which the manner of death was mostly assumed to be a suicide. The shotgun injury presented the billiard ball ricochet effect, in which a large wound was formed on the inner side of the left thoracic cavity by spraying out of pellets while a small entry wound by bunched pellets was on the left anterior chest wall.
Autopsy
;
Firearms
;
Humans
;
Korea
;
Mass Media
;
Middle Aged
;
Suicide
;
Thoracic Cavity
;
Thoracic Wall
3.Preclinical Evaluation of an Everolimus-Eluting Bioresorbable Vascular Scaffold Via a Long-Term Rabbit Iliac Artery Model
Dae Sung PARK ; Myung Ho JEONG ; Yu Jeong JIN ; Mi Hyang NA ; Doo Sun SIM ; Munki KIM ; Kyung Hoon CHO ; Dae Young HYUN ; Seok OH ; Jeong Ha KIM ; Kyung Seob LIM ; Jun-Kyu PARK ; Han Ki KIM ; Young Joon HONG ; Ju Han KIM ; Youngkeun AHN ; Jeong Hun KIM
Tissue Engineering and Regenerative Medicine 2023;20(2):239-249
BACKGROUND:
Biodegradable poly (l-lactic acid) (PLLA), a bio safe polymer with a large elastic modulus, is widely used in biodegradable medical devices. However, because of its poor mechanical properties, a PLLA strut must be made twice as thick as a metal strut for adequate blood vessel support. Therefore, the mechanical properties of a drug-eluting metal-based stents (MBS) and a bioresorbable vascular scaffolds (BVS) were evaluated and their safety and efficacy were examined via a long-term rabbit iliac artery model.
METHODS:
The surface morphologies of the MBSs and BVSs were investigated via optical and scanning electron microscopy. An everolimus-eluting (EE) BVS or an EE-MBS was implanted into rabbit iliac arteries at a 1.1:1 stent-toartery ratio. Twelve months afterward, stented iliac arteries from each group were analyzed via X-ray angiography, optical coherence tomography (OCT), and histopathologic evaluation.
RESULTS:
Surface morphology analysis of the EE coating on the MBS confirmed that it was uniform and very thin (4.7 lm). Comparison of the mechanical properties of the EE-MBS and EE-BVS showed that the latter outperformed the former in all aspects (radial force (2.75 vs. 0.162 N/mm), foreshortening (0.24% vs. 1.9%), flexibility (0.52 vs. 0.19 N), and recoil (3.2% vs. 6.3%). At all time points, the percent area restenosis was increased in the EE-BVS group compared to the EE-MBS group. The OCT and histopathological analyses indicate no significant changes in strut thickness.
CONCLUSION
BVSs with thinner struts and shorter resorption times should be developed. A comparable long-term safety/efficacy evaluation after complete absorption of BVSs should be conducted.
4.Effect of Stents Coated with Artemisinin or Dihydroartemisinin in a Porcine Coronary Restenosis Model.
Suyoung JANG ; Myung Ho JEONG ; Kyung Seob LIM ; In Ho BAE ; Jun Kyu PARK ; Dae Sung PARK ; Jae Won SHIM ; Jung Ha KIM ; Hyun Kuk KIM ; Doo Sun SIM ; Young Joon HONG ; Youngkeun AHN ; Jung Chaee KANG
Korean Circulation Journal 2017;47(1):115-122
BACKGROUND AND OBJECTIVES: Artemisinin and dihydroartemisinin are drugs used to treat malaria. These drugs suppress inflammatory reactions. The aim of this study was to examine the anti-intima hyperplasia effect of a novel drug-eluting stent with artemisinin or dihydroartemisinin in a porcine coronary restenosis model. MATERIALS AND METHODS: Pigs were randomized into four groups; in the first, the coronary arteries (20 pigs, a total of 40 coronary arteries, with 10 coronary arteries in each group) was implanted with bare metal stents (BMS, n=10); the second group was given polymer-coated stents (PCS, n=10); the third group was treated with artemisinin-eluting stents (AES, n=10); and the fourth group was given dihydroartemisinin-eluting stents (DAES, n=10). Histopathologic analysis was performed 28 days after stenting. RESULTS: The injury and fibrin scores among the four groups were not significantly different. However, the internal elastic lamina, lumen area, and neointima area were significantly different. Moreover, the percent area of stenosis (46.2±18.66% in BMS vs. 89.4±10.92% in PCS vs. 83.3±17.07% in AES vs. 36.7±11.20% in DAES, p<0.0001) and inflammation score (1.0 [range: 1.0-1.0] vs. 3.0 [range: 2.25-3.0] vs. 3.0 [range: 1.0-3.0] vs. 2.0 [range: 1.75-3.0] in BMS, PCS, AES, and DAES, respectively; p<0.001) were markedly decreased in the DAES group compared to the PCS group. CONCLUSION: DES, which uses a natural substance, dihydroartemisinin, showed a neointima and inflammatory suppressive effect in a porcine coronary restenosis model.
Constriction, Pathologic
;
Coronary Restenosis*
;
Coronary Vessels
;
Drug-Eluting Stents
;
Fibrin
;
Hyperplasia
;
Inflammation
;
Malaria
;
Neointima
;
Stents*
;
Swine