1.A gastroesophageal cyst in the posterior mediastinum.
Hwa Kyun SHIN ; Yong Jai LEE ; Jeong Kwan KOH ; Hyung Joo PARK ; Chol Sae LEE
The Korean Journal of Thoracic and Cardiovascular Surgery 1993;26(9):738-741
No abstract available.
Mediastinum*
2.Implant surface treatments affect gene expression of Runx2, osteogenic key marker.
Young NA ; Seong Joo HEO ; Seong Kyun KIM ; Jai Young KOAK
The Journal of Advanced Prosthodontics 2009;1(2):91-96
STATEMENT OF PROBLEM: The aim of this study was to study the effects of various surface treatments to a titanium surface on the expression of Runx2 in vitro. MATERIAL AND METHODS: Human Osteosarcoma TE-85 cells were cultured on machined, sandblasted, or anodic oxidized cpTi discs. At various times of incubation, the cells were collected and then processed for the analysis of mRNA expression of Runx2 using reverse transcription-PCR. RESULTS: The expression pattern of Runx2 mRNA was differed according to the types of surface treatment. When the cells were cultured on the untreated control culture plates, the gene expression of Runx2 was not increased during the experiments. In the case of that the cells were cultured on the machined cpTI discs, the expression level was intermediate at the first day, but increased constitutively to day 5. In cells on sandblasted cpTi discs, the expression level was highest in the first day sample and the level was maintained to 5 days. In cells on anodized cpTi discs, the expression level increased rapidly to 3 days, but decreased slightly in the 5-th day sample. CONCLUSION: Different surface treatments may contribute to the regulation of osteoblast function by influencing the level of gene expression of key osteogenic factors.
Durapatite
;
Gene Expression
;
Humans
;
Osteoblasts
;
Osteogenesis
;
Osteosarcoma
;
RNA, Messenger
;
Titanium
3.Full mouth rehabilitation of partially and fully edentulous patient with crown lengthening procedure: a case report.
Hyon Woo SEOL ; Jai Young KOAK ; Seong Kyun KIM ; Seong Joo HEO
The Journal of Advanced Prosthodontics 2010;2(2):50-53
BACKGROUND: In order to restore severely attrited teeth properly, surgical intervention in the form of a crown-lengthening procedure may be required. And also, proper diagnosis and treatment sequencing is critical to obtain a successful results. Adequate diagnostic wax-up ensures good esthetics and healthy periodontal tissue. CASE DESCRIPTION: This clinical case report describes a diagnostically based protocol for restoration on mandibular anterior teeth with crown lengthening procedure and the treatment of partially edentulous mandible combined with an edentulous maxilla. In addition, the effort to prevent the combination syndrome was described. CLINICAL IMPLICATION: An interdisciplinary diagnosis and examination through visualization of the desired results ensure conservative and more predictable outcome.
Crown Lengthening
;
Crowns
;
Dietary Sucrose
;
Esthetics
;
Humans
;
Mandible
;
Maxilla
;
Mouth
;
Mouth Rehabilitation
;
Tooth
4.Full mouth rehabilitation of destroyed dentition with rotational path removable partial denture: a case report.
Moon Hyoung KIM ; Seong Joo HEO ; Seong Kyun KIM ; Jai Young KOAK
The Journal of Advanced Prosthodontics 2010;2(2):46-49
BACKGROUND: Though implant dentistry is very successful and predictable in treatment of patients with destroyed dentition, there are some cases with limitations to implant therapy. In these cases, alternative treatment modality should be considered. CASE DESCRIPTION: A patient with destroyed dentition was rehabilitated with a lateral rotational path removable partial denture. According to the diagnosis, we determined to raise vertical dimension for esthetic and functional restoration. The final restoration was performed after four months of provisional period. CLINICAL IMPLICATION: The edentulous patients with compromised esthetics and functions can be successfully treated with a rotational path removable partial denture through adequate treatment planning and precise laboratory procedure.
Dentistry
;
Dentition
;
Denture, Partial, Removable
;
Esthetics
;
Humans
;
Mouth
;
Mouth Rehabilitation
;
Tooth Attrition
;
Vertical Dimension
5.A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables.
Su Young LEE ; Chunmei PIAO ; Seong Joo HEO ; Jai Young KOAK ; Joo Hee LEE ; Tae Hyung KIM ; Myung Joo KIM ; Ho Beom KWON ; Seong Kyun KIM
The Journal of Advanced Prosthodontics 2010;2(4):148-153
PURPOSE: The aim of this study was to investigate a comparison of implant bone bed preparation with Er,Cr:YSGG laser and conventional drills on the relationship between implant stability quotient (ISQ) values and implant insertion variables. MATERIALS AND METHODS: Forty implants were inserted into two different types of pig rib bone. One group was prepared with conventional drills and a total of 20 implants were inserted into type I and type II bone. The other group was prepared with a Er,Cr:YSGG laser and a total of 20 implants were inserted into type I and type II bone. ISQ, maximum insertion torque, angular momentum, and insertion torque energy values were measured. RESULTS: The mean values for variables were significantly higher in type I bone than in type II bone (P < .01). In type I bone, the ISQ values in the drill group were significantly higher than in the laser group (P < .05). In type II bone, the ISQ values in the laser group were significantly higher than in the drill group (P < .01). In both type I and type II bone, the maximum insertion torque, total energy, and total angular momentum values between the drill and laser groups did not differ significantly (P > or = .05). The ISQ values were correlated with maximum insertion torque (P < .01, r = .731), total energy (P < .01, r = .696), and angular momentum (P < .01, r = .696). CONCLUSION: Within the limitations of this study, the effects of bone bed preparation with Er,Cr:YSGG laser on the relationship between implant stability quotient (ISQ) values and implant insertion variables were comparable to those of drilling.
Mandrillus
;
Ribs
;
Salicylates
;
Torque
6.Influence of the accuracy of abutment tooth preparation on the marginal adaptation of Co-Cr alloy copings fabricated with a selective laser sintering technology.
Seo Rahng KIM ; Jai Young KOAK ; Seong Joo HEO ; Seong Kyun KIM ; Myung Joo KIM
The Journal of Korean Academy of Prosthodontics 2015;53(4):337-344
PURPOSE: The purpose of present study is to examine the correlation between the accuracy of abutment preparation and the marginal adaptation of metal coping. With this view, this study compared the correlations regard to the three different manufacturing methods of selective laser sintering technique, milling and casting. MATERIALS AND METHODS: Two master models were made in a different way. First model with deep chamfer margin was prepared directly by a general clinician and the second model was designed by 3-D designing software program with the same abutment preparation principle and produced by computer aided manufacturing. 12 Co-Cr alloy copings were produced respectively with three different method; SLS system, CAD/CAM milling and conventional lost wax technique from each master model. The total 72 copings fully sit on the master model were stereoscopically evaluated at 40 points along the entire circumferential margin. RESULTS: Significant differences in the absolute marginal discrepancies of Co-Cr copings from SLS system (P=.0231) and casting method (P<.0001) were shown between hand preparation model and computer designed model. However, no significant difference was found between the two model groups from milling method (P=.9962). CONCLUSION: Within the limitation of this study, the effect of the accuracy of abutment preparation on the marginal adaptation of Co-Cr coping is statistically significant in SLS system and casting group. The copings produced by SLS system exhibited the lowest marginal discrepancies among all groups, and the marginal gap of this method group was influenced by the accuracy of the abutment preparation.
Alloys*
;
Computer-Aided Design
;
Dental Abutments
;
Hand
;
Tooth Preparation*
;
Tooth*
7.Development of predictable stability test for assessment of optimum loading time in dental implant.
Seong Kyun KIM ; Seong Joo HEO ; Jai Young KOAK ; Joo Hee LEE ; Ji Yong KWON
The Journal of Korean Academy of Prosthodontics 2008;46(6):628-633
STATEMENT OF PROBLEM: The application of a simple, clinically applicable noninvasive test to assess implant stability are considered highly desirable. So far there is still a controversy about correlation of various tests and implant stability. PURPOSE: In order to assess implant stability, the development of a new method is critical. It' s possible to assess implant stability by calculating energy and angular momentum during implant installation. The purpose of this study is to evaluate the correlation of energy and implant stability. MATERIAL AND METHODS: Twenty three implants were installed in two different types of pig bone. Type I bone was retrieved from the distal aspect of the rib, with more cortical bone. Type II bone came from a more proximal region with less cortical components and a higher content of bone marrow and spongeous trabeculae. Insertion torque, removal torque, ISQ values and angular momentum and energy were measured. Pearson Correlation test was done to analyze the relation between RFA, maximum insertion torque, mean insertion torque, bone type, energy and removal torque. RESULTS: Type I bone showed higher removal torque than type II bone. Energy value was significantly correlated with maximum insertion torque and mean insertion torque. RFA values were related with insertion torques but the significance was lower than Energy value. CONCLUSION: Within the limitation of this study energy values were considered clinically predictable method to measure the implant stability.
Bone Marrow
;
Dental Implants
;
Porphyrins
;
Ribs
;
Salicylates
;
Torque
8.Cellular responses on anodized titanium discs coated with 1 alpha,25-dihydroxyvitamin D3 incorporated Poly(D,L-lactide-co-glycolide) (PLGA) nanoparticles.
Young Jin CHO ; Seong Joo HEO ; Jai Young KOAK ; Seong Kyun KIM ; Joo Hee LEE
The Journal of Korean Academy of Prosthodontics 2008;46(6):620-627
STATEMENT OF PROBLEM: A biochemical approach for surface modification has offered an alternative for physicochemical and morphological methods to obtain desirable bone-implant interfaces. PURPOSE: The purpose of the present study was to investigate cell responses to poly (D,L-lactide-co-glycolide) (PLGA)/1alpha, 25-(OH)2D3 coating with reference to cellular proliferation and differentiation in vitro. MATERIAL AND METHODS: 96 titanium discs were fabricated and divided into four groups. Group 1 was anodized under 300 V as control. Group 2, 3 and 4 were anodized then coated with 3 ml PLGA/1alpha, 25-(OH)2D3 solutions. Amount of the solutions were 2 ul, 20 ul and 200ul respectively. The osteoblast-like Human Osteogenic Sarcoma (HOS) cells were seeded and cultured for 1, 3 and 7 days. MTSbased cell proliferation assay and ALPase activity test were carried out. RESULTS: PLGA nanoparticles were observed as fine, smooth and round and HOS cells attached to the anodized surfaces through strand-like and sheet-like filopodia. After 3 days of culture, the dendritic filopodia were exaggerated and sheet-like cytoplasmic projections covered the coated titanium surfaces. After 3 days of culture, all of the groups showed increased cellular proliferation and the lowest proliferation rate was measured on group 2. Higher amount of incorporated 1 alpha, 25-(OH)2D3 (Group 3 and 4) improved cellular proliferation but the differences were not significant statistically (P > .05). But they increased the rate of ALP activities than the control group at day 3 (P < .05). CONCLUSION: Biodegradable PLGA nanoparticles incorporated with vitamin D metabolite positively affected proliferation and differentiation of cells on the anodized titanium surface.
Calcitriol
;
Cell Proliferation
;
Cytoplasm
;
Humans
;
Lactic Acid
;
Nanoparticles
;
Osteosarcoma
;
Polyglycolic Acid
;
Pseudopodia
;
Seeds
;
Titanium
;
Vitamin D
9.Influence of finish line design on the marginal fit of nonprecious metal alloy coping fabricated by 3D printing, milling and casting using CAD-CAM
Seo-Rahng KIM ; Myung-Joo KIM ; Ji-Man PARK ; Seong-Kyun KIM ; Seong-Joo HEO ; Jai-Young KOAK
The Journal of Korean Academy of Prosthodontics 2023;61(1):1-17
Purpose:
The purpose of this study was to examine the correlation between the finish line designs and the marginal adaptation of nonprecious metal alloy coping produced by different digital manufacturing methods.
Materials and methods:
Nonprecious metal alloy copings were made respectively from each master model with three different methods; SLS, milling and casting by computer aided design and computer aided manufacturing (CAD-CAM). Twelve copings were made by each method resulting in 72 copings in total. The measurement was conducted at 40 determined reference points along the circumferential margin with the confocal laser scanning microscope at magnification ×150.
Results
Mean values of marginal gap of laser sintered copings were 11.8 ± 7.4 μm for deep chamfer margin and 6.3 ± 3.5 μm for rounded shoulder margin and the difference between them was statistically significant (P < .0001). Mean values of marginal gap of casted copings were 18.8 ± 20.2 μm for deep chamfer margin and 33 ± 20.5 μm for rounded shoulder margin and the difference between them was significant (P = .0004). Conclusion: Within the limitation of this study, the following conclusions were drawn. 1. The variation of finish line design influences the marginal adaptation of laser sintered metal coping and casted metal coping. 2. Laser sintered copings with rounded shoulder margin had better marginal fit than deep chamfer margin. 3. Casted copings with deep chamfer margin had better marginal fit than rounded shoulder margin. 4. According to the manufacturing method, SLS system showed the best marginal fit among three different methods. Casting and milling method followed that in order.
10.Malignant Gastrointestinal Stromal Tumor of Mesentery Origin: Case Report.
Myong Hee SEO ; Jae Chan SHIM ; Mee JOO ; Seok Jong RYU ; Ghi Jai LEE ; Ho Kyun KIM
Journal of the Korean Radiological Society 2002;47(6):631-634
A primary tumor of mesenteric origin is rare. We encountered a malignant gastrointestinal stromal tumor (GIST) of mesenteric origin that demonstrated severe necrosis, and report the CT findings and review the literature.
Gastrointestinal Stromal Tumors*
;
Mesentery*
;
Necrosis