1.THE RETRIEVABILITY OF CEMENTATION TYPE IMPLANT ABUTMENT BY SURFACE TREATMENTS AND TYPES OF CEMENTS.
The Journal of Korean Academy of Prosthodontics 1999;37(5):651-657
This study was performed to investigate the retrievability of the cementation type implant abutments. The cements used in this study were Cavitec, Tembond and Zine Phosphate Cement. The types of surface conditioning were no treatment, 50 microne sandblasting, 250 microne sandblasting, fine diamond finishing point and coarse diamond point. The retention of cast crown was measured with Instron University Testing Machine(Instron Engineering Co., U.S.A.) The results were as follows: 1. The Maximium retention was obtained by the group of Z.P.C. cementation and Coarse diamond point surface conditioning. 2. Z.P.C. shows maximum retention, and reduced in orders Tembond, Cavitec, No cement. 3. The value of retention of surface condition was highest in coarse diamond point, lowest in no tretment. 4. The similar results were obtained between fine diamond point and 50 microne sandblasting, coarse diamond point and 250 microne sandblasting. 5. The were no direct corelation between mechanical retetnion and cementation retention.
Cementation*
;
Crowns
;
Diamond
2.Statistical Study on Optimal Placement of Immediate Dental Implantation Using Denta Scanr.
Kwang Ho SHIN ; Jai Bong LEE ; Byung Nam HWANG
The Journal of Korean Academy of Prosthodontics 2000;38(4):552-560
PURPOSE : The purpose of this study was to determine proper position and angulation of an implant for immediate implantation. MATERIALS AND METHOD : From the years 1997 to 2000, 52 Denta scanR views, 22 upper and 32 lower jaw with an average age of 43 and 40 respectively, were investigated, which comprise intact upper and lower 6 anterior teeth and premolars. on the Denta scanR, the optimal placement for the immediated implantation was simulated. The measuring methods included. 1) Angulation difference between tooth long axis and alveolar bone process. 2) Angulation difference of long axis between tooth and installing fixture 3) Distance between center of tooth at cervical area and center of fixture. 4) Distance from root apex to the bone limit of vital structure. One sample t-test was used for statistical analysis. RESULT : The results were as follows. 1) At the maxillary central incisor and lateral incisor, angulation difference of long axis between tooth and installing fixture was respectively 0.5 and 3.2degrees with the fixture center's palatally positioned 2mm apart from tooth center. 2) At the lower anterior 6 teeth, that was about -2.8degree to -4.6degree with the fixture center's lingually positioned 1mm apart from tooth center. 3) At the maxillary canine and premolar, that was respectively 11.8degree and 7.2degree with the fixture center palatally positioned 2~2.4mm apart from tooth center. 4) At the lower premolar area, that was about 0degree to 2degree with the fixture center's lingually positioned 0.5~1mm apart from tooth center. 5) Distance from root apex to the bone limit of vital structure, at the maxillary anterior and premolars, was the range of 10 to 12mm, and at the mandibular anterior teeth and the 1st premolar, that was the range of 18 to 20mm. CONCLUSION : The proper implant position of maxillary anterior and premolar teeth is as paralleled as or more buccally angulated than long axis of tooth with the fixture center's palatally positioned. in mandibular anterior region, long axis of implants is lingully angulated compared with compared with long axis of tooth and in premolar, almost parelleled with long axis of tooth and alveolar process.
Alveolar Process
;
Axis, Cervical Vertebra
;
Bicuspid
;
Dental Implantation*
;
Dental Implants*
;
Incisor
;
Jaw
;
Statistics as Topic*
;
Tooth
3.Occupational Rediodermatitis: Report of 4 Cases.
Kea Jeung KIM ; Bong Koo LEE ; Hyung Jai KANG
Korean Journal of Dermatology 1989;27(6):686-690
Recently radiation and radioisotope are being used widely in many fields such as medicine and industry. But only a few papers were reported about the radio dermatitis due to industrial use of radiation. Authors experienced 4 cases of occupational radiodermatitis due to Ir-192 occur red during the radioisotope traspierce test. All 4 patients noticed painful swelling, erythema, and bullae on their fingers or palms 1-2 weeks after exposure. All laboratory tests to detect ystemic effects of radiation were normal. Three patients recovered after treatment with systemic and topical corticosteroid and emollient cream for 2-4 weeks. But one patient suffered from complication of fibrosis and recurrent cellulitis on his fingers. We discussed about the working situation of our patients and reviewed the literatures about the radiodermatitis.
Cellulitis
;
Dermatitis
;
Erythema
;
Fibrosis
;
Fingers
;
Humans
;
Radiodermatitis
4.FRACTURE TOUGHNESS OF VARIOUS CORE MATERIALS.
Shin Won LEE ; Sun Hyung LEE ; Jae Ho YANG ; Jung Suk HAN ; Jai Bong LEE
The Journal of Korean Academy of Prosthodontics 2001;39(6):682-697
This investigation evaluated the fracture toughness (KIC) of eight currently available core materials, and relate the fracture toughness value to fractography analysis and surface characteristics using a atomic force microscope (AFM). Single-edge notched (SEN) test specimens (n=10) and compact tension (CT) test specimens (n=10) were prepared conforming to the ASTM Standard E-399 for a high copper amalgam, three composite core materials (Core-Max II, Core Paste, Bisfil Core), two reinforced composite core materials (Ti-Core, Ti-Core Natural), a resin-modified glass ionomer core material (Vitremer), and a conventional glass ionomer core material (Ketac-Molar). The specimens were tested with an Instron Universal Testing Machine. The maximum loads were measured to calculate the fracture toughness (KIC). Thereafter, fracture surfaces of SEN specimens of each material were investigated for fractography analysis using scanning electron microscope. And, disc-shaped specimens with 1mm thickness were fabricated for each material and were investigated under AFM for surface morphology analysis. The results were as follows : 1. Bisfil Core showed the highest mean fracture toughness regardless of test methods. 2. For the tooth-colored materials, Ti-Core Natural exhibited the highest fracture toughness. 3. Ketac Molar showed a significantly low fracture toughness when compared with the amalgam and the composite resin core materials (p<0.05). 4. The fracture toughness values obtained with the single-edge notched test, except Ketac Molar, were higher than those obtained in the compact tension test. 5. SEM revealed that the fracture surface of high fracture toughness material was rougher than that of low fracture toughness material. 6. AFM revealed that the surface particles of the composite resins were smaller in size, with a lower surface roughness than the glass ionomer core materials.
Composite Resins
;
Copper
;
Glass
;
Molar
5.Trend analysis of prosthodontic treatment modality between 2005 and 2008 in Seoul National University Dental Hospital.
Hongbo LI ; Jai Bong LEE ; Hongchen LIU ; Jung Suk HAN ; Jae Ho YANG ; Jai Young KOAK ; Seong Joo HEO
The Journal of Advanced Prosthodontics 2010;2(1):4-6
PURPOSE: The aim of this article is to analyze the preference for treatment modality of dentists. MATERIAL AND METHODS: Data of 20,038 patients was involved. Data analysis were done by distribution according to the various kinds of prosthesis, including complete denture, removable partial denture, fixed partial denture, implant-supported dental prosthesis as well as distribution according to the professional titles of the dentists finishing the treatment, including resident and professors. RESULTS: The number of cases of dental prosthesis increased year by year. 61.06% of the patients accepted fixed partial denture restoration. The number of patients who accepted implant supported restoration is also increasing year by year. The number of complete denture, implant-supported dental prosthesis finished by professors was larger than that done by residents, while it was contrary for removable partial denture, fixed partial denture, and the difference was statistically significant (P<.05). CONCLUSION: Professors and residents have some difference in the categorization of prosthesis finished. Fixed partial denture and implant-supported dental prosthesis are preferred.
Dental Prosthesis
;
Dental Prosthesis, Implant-Supported
;
Dentists
;
Denture, Complete
;
Denture, Partial, Fixed
;
Denture, Partial, Removable
;
Humans
;
Prostheses and Implants
;
Prosthodontics
;
Statistics as Topic
6.Three dimensional finite element analysis of internally connected implant systems.
Yu Lee KIM ; Hye Won CHO ; Jai Bong LEE
The Journal of Korean Academy of Prosthodontics 2006;44(1):85-102
STATEMENT OF PROBLEM: Currently, there are some 20 different geometric variations in implant/abutment interface available. The geometry is important because it is one of the primary determinants of joint strength, joint stability, locational and rotational stability. PURPOSE: As the effects of the various implant-abutment connections and the prosthesis height variation on stress distribution are not yet examined, this study is to focus on the different types of implant-abutment connection and the prosthesis height using three dimensional finite element analysis. MATERIAL AND METHOD: The models were constructed with ITI, 3i TG, Bicon, Frialit-2 fixtures and solid abutment, TG post, Bicon post, EstheticBase abutment respectively. And the superstructures were constructed as mandibular second premolar shapes with 8.5 mm, 11 mm, 13.5 mm of crown height. In each model, 244 N of vertical load and 244 N of 30 degree oblique load were placed on the central pit of an occlusal surface. von Mises stresses were recorded and compared in the crowns, abutments, fixtures. RESULTS: 1. Under the oblique loading, von Mises stresses were larger in the crown, abutment, fixture compared to the vertical loading condition. 2. The stresses were increased proportionally to the crown height under oblique loading but showed little differences with three different crown heights under vertical loading. 3. In the crown, the highest stress areas were loading points under vertical loading, and the finish lines under oblique loading. 4. Under the oblique loading, the higher stresses were located in the fixture/abutment interface of the Bicon and Frialit-2 systems compared to the ITI and TG systems. CONCLUSIONS: The stress distribution patterns of each implant-abutment system had difference among them and adequate crown height/implant ratio was important to reduce the stresses around the implants.
Bicuspid
;
Crowns
;
Finite Element Analysis*
;
Joints
;
Prostheses and Implants
7.Three dimensional finite element analysis of internally connected implant systems.
Yu Lee KIM ; Hye Won CHO ; Jai Bong LEE
The Journal of Korean Academy of Prosthodontics 2006;44(1):85-102
STATEMENT OF PROBLEM: Currently, there are some 20 different geometric variations in implant/abutment interface available. The geometry is important because it is one of the primary determinants of joint strength, joint stability, locational and rotational stability. PURPOSE: As the effects of the various implant-abutment connections and the prosthesis height variation on stress distribution are not yet examined, this study is to focus on the different types of implant-abutment connection and the prosthesis height using three dimensional finite element analysis. MATERIAL AND METHOD: The models were constructed with ITI, 3i TG, Bicon, Frialit-2 fixtures and solid abutment, TG post, Bicon post, EstheticBase abutment respectively. And the superstructures were constructed as mandibular second premolar shapes with 8.5 mm, 11 mm, 13.5 mm of crown height. In each model, 244 N of vertical load and 244 N of 30 degree oblique load were placed on the central pit of an occlusal surface. von Mises stresses were recorded and compared in the crowns, abutments, fixtures. RESULTS: 1. Under the oblique loading, von Mises stresses were larger in the crown, abutment, fixture compared to the vertical loading condition. 2. The stresses were increased proportionally to the crown height under oblique loading but showed little differences with three different crown heights under vertical loading. 3. In the crown, the highest stress areas were loading points under vertical loading, and the finish lines under oblique loading. 4. Under the oblique loading, the higher stresses were located in the fixture/abutment interface of the Bicon and Frialit-2 systems compared to the ITI and TG systems. CONCLUSIONS: The stress distribution patterns of each implant-abutment system had difference among them and adequate crown height/implant ratio was important to reduce the stresses around the implants.
Bicuspid
;
Crowns
;
Finite Element Analysis*
;
Joints
;
Prostheses and Implants
8.A case of pemphigus erythematosus.
Kee Yeon KIM ; Bong Goo LEE ; Kea Jeung KIM ; Chang Woo LEE ; Hyung Jai KANG
Korean Journal of Dermatology 1991;29(1):91-94
We present here, a case of pemphigus erythematosus developed in a 31-year-old woman, who had been suffering from repeated episode, of remission and exacerbation with several erythematous, and somewhat oozing patche accompanying a mild pruritus or her face, upper part of the back and anterior chest. In serological studies, she had antinuclear antiboc@lies at. a titer of 1:160. Histopathological finding showed subcorneal bullae. Immunofluorescent study revealed IgG and C, deposition in the intercellular space of the epidermis and along the de rmoepidermal junction.
Adult
;
Epidermis
;
Extracellular Space
;
Female
;
Fluorescent Antibody Technique
;
Humans
;
Immunoglobulin G
;
Pemphigus*
;
Pruritus
;
Thorax
9.A study of garlic sensitivity in patients with hand eczema.
Bong Koo LEE ; Kea Jeung KIM ; Hyung Jai KANG ; Hee Chul EUN ; Jeong Aee KIM
Korean Journal of Dermatology 1992;30(2):197-201
The importance of garlic as a cause of hand eczema has been a matter of debate. Diallyldisulfide is considered as the main allergen in garlic. Twentv two antigens of the modified European standard series and diallyldisulfide of 5%, 2%, 1%, 0.5%, 0.1% in petrolatum were patch tested in 44 patients with hand eczema. Diallylclisi.!lfide was also tested in 13 women as a control. The results were summerized as follows. l. In patch testing with the European standard series, nickel sulfate (22.7%), cobalt chloride (18.2%), fragrance mix (13.6%), balsam of Peru (9.1%) and termerosal (6.8%) were the cornmon allergens which showed positive reactions. The overal positive rate was 59.1 % (26/44). 2.5% diallyldisulfide showed an irritant reaction in 6 (46.2%) out of 13 controls and in 16 (36.4% ) out of 44 patients. 2% diallyldisulfide showed an irritant reaction in 2/13 (15.4 %) in the control group and 6/44 (13.6%) in the patient group. All 13 controls and 44 patients were negative iin tests with diallyldisulfide of 1%, 0.5%, 0.1%. Our results indicate that patch testing with diallyldisulfide of 1% petrolatum is reommended in order to avoid an irritant reaction when contact allergy to garlic is suspetel. 3. Garlic is suspected as an irritant in provoking hand eczema. True contact allergy to garlic in hand eczema seems to be rare.
Allergens
;
Cobalt
;
Eczema*
;
Female
;
Garlic*
;
Hand*
;
Humans
;
Hypersensitivity
;
Nickel
;
Patch Tests
;
Peru
;
Petrolatum
10.A comparative study on the correlation between Korean foods and the fractures of PFG and all ceramic crowns for posterior applications.
The Journal of Korean Academy of Prosthodontics 2009;47(2):156-163
STATEMENT OF PROBLEM: Recently, there have been increased esthetic needs for posterior dental restorations. The failure of posterior dental ceramic restoration are possible not only by the characters of the component materials but also by the type of food. PURPOSE: The research aim was to compare the in vitro fracture resistance of simulated first molar crowns fabricated using 4 dental ceramic systems, full-porcelain-occlusal-surfaced PFG, half-porcelain-occlusal-surfaced PFG, Empress 2, Ice Zirkon and selected Korean foods. MATERIAL AND METHODS: Eighty axisymmetric crowns of each system were fabricated to fit a preparation with 1.5- to 2.0-mm occlusal reduction. The center of the occlusal surface on each of 15 specimens per ceramic system was axially loaded to fracture in a Instron 4465, and the maximum load (N) was recorded. Afterwards, selected Korean foods specimens (boiled crab, boiled chicken with bone, boiled beef rib, dried squid, dried anchovy, round candy, walnut shell) were prepared. 15 specimens per each food were placed under the Instron and the maximum fracture loads for them were recorded. The 95% confidence intervals of the characteristic failure load were compared between dental eramic systems and Korean foods. Afterwards, on the basis of previous results, 14Hz cyclic load was applied on the 4 systems of dental ceramic restorations in MTS. The reults were analyzed by analysis of variance and Post Hoc tests. RESULTS: 95% confidence intervals for mean of fracture load 1. full porcelain occlusal surfaced PFG Crown: 2599.3 to 2809.1 N 2. half porcelain occlusal surfaced PFG Crown: 3689.4 to 3819.8 N 3. Ice Zirkon Crown: 1501.2 to 1867.9 N 4. Empress 2 Crown: 803.2 to 1188.5 N 5. boiled crab: 294.1 to 367.9 N 6. boiled chicken with bone: 357.1 to 408.6 N 7. boiled beef rib: 4077.7 to 4356.0 N 8. dried squid: 147.5 to 190.5 N 9. dried anchovy: 35.6 to 46.5 N 10. round candy: 1900.5 to 2615.8 N 11. walnut shell: 85.7 to 373.1 N under cyclic load (14Hz) in MTS, fracture load and masticatory cycles are: 1. full porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 4796.8 - 9321.2 cycles under 2224.8 N (round candy)load, no fracture under smaller loads. 2. half porcelain occlusal surfaced PFG Crown fractured at 95% confidence intervals of 881705.1 - 1143565.7 cycles under 2224.8 N (round candy). no fracture under smaller loads. 3. Ice Zirkon Crown fractured at 95% confidence intervlas of 979993.0 - 1145773.4 cycles under 382.9 N (boiled chicken with bone). no fracture under smaller loads. 4. Empress 2 Crown fractured at 95% confidence intervals of 564.1 - 954.7 cycles under 382.9 N (boiled chicken with bone). no fracture under smaller loads. CONCLUSION: There was a significant difference in fracture resistance between experimental groups. Under single load, Korean foods than can cause fracture to the dental ceramic restorations are boiled beef rib and round candy. Even if there is no fracture under single load, cyclic dynamic load can fracture dental posterior ceramic crowns. Experimental data with 14 Hz dynamic cyclic load are obtained as follows. 1. PFG crown (full porcelain occlusion) was failed after mean 0.03 years under fracture load for round candy (2224.8 N). 2. PFG crown(half porcelain occlusion) was failed after mean 4.1 years under fracture load for round candy (2224.8 N). 3. Ice Zirkon crown was failed after mean 4.3 years under fracture load for boiled chicken with bone (382.9 N). 4. Empress 2 crown was failed after mean 0.003 years under fracture load for boiled chicken with bone (382.9 N).
Candy
;
Ceramics
;
Chickens
;
Crowns
;
Decapodiformes
;
Dental Porcelain
;
Ice
;
Juglans
;
Lithium Compounds
;
Molar
;
Ribs