1.Survey of the Knowledge of Korean Radiology Residents on Medical Artificial Intelligence
Hyeonbin LEE ; Seong Ho PARK ; Cherry KIM ; Seungkwan KIM ; Jaehyung CHA
Journal of the Korean Radiological Society 2020;81(6):1397-1411
Purpose:
To survey the perception, knowledge, wishes, and expectations of Korean radiology residents regarding artificial intelligence (AI) in radiology.
Materials and Methods:
From June 4th to 7th, 2019, questionnaires comprising 19 questions related to AI were distributed to 113 radiology residents. Results were analyzed based on factors such as the year of residency and location and number of beds of the hospital.
Results:
A total of 101 (89.4%) residents filled out the questionnaire. Fifty (49.5%) respondents had studied AI harder than the average while 68 (67.3%) had a similar or higher understanding of AI than the average. In addition, the self-evaluation and knowledge level of AI were significantly higher for radiology residents at hospitals located in Seoul and Gyeonggi-do compared to radiology residents at hospitals located in other regions. Furthermore, the self-evaluation and knowledge level of AI were significantly lower in junior residents than in residents in the 4th year of training. Of the 101 respondents, only 16 (15.8%) had experiences in AI-related study while 91 (90%) were willing to participate in AI-related study in the future.
Conclusion
Organizational efforts through a radiology society would be needed to meet the need of radiology trainees for AI education and to promote the role of radiologists more adequately in the era of medical AI.
2.Current State of Abdominal Computed Tomography Performed in Emergency Department of a Tertiary University Hospital and Development of a Preliminary Interpretation Checklist.
Junyoung SUH ; Juhyun SONG ; Sungwoo MOON ; Hanjin CHO ; Jonghak PARK ; Jooyoung KIM ; Seoungho JEON ; Jaehyung CHA
Journal of the Korean Society of Emergency Medicine 2016;27(4):336-344
PURPOSE: Abdominal computed tomography (CT) is a widely recognized method to diagnose patients with acute abdominal pain in the emergency departments (EDs). We aimed to investigate the current state and interpretations of abdominal CT performed in the ED of a tertiary university hospital. METHODS: This was a retrospective study based on an abdominal CT database and medical records of patients over 15 years of age, who had visited our ED between January 1 and December 31, 2013. The data collected included CT types, final interpretations, characteristics of the patients, and location of pain at the time of CT. RESULTS: A total of 1,978 abdominal CTs were performed among 1,923 patients during the research period. The most frequent organs involved in the major diagnosis were those in the urinary system, followed by the appendix, liver, large intestine, and gallbladder. The most frequently interpreted diagnoses in these organs were in the order of urinary stone, appendicitis, liver cirrhosis, infectious colitis, and acute cholecystitis. The most frequent location of pain was the right lower quadrant (429 cases, 21.7%), and the most frequently performed CT types were contrast-enhanced abdominal and pelvic CT (1,260 cases, 63.7%). CONCLUSION: Various interpretations were derived based on the abdominal CTs, ranging from critical to mild diseases and from common to rare diseases. Based on this study, we have developed a preliminary interpretation checklist for abdominal CTs.
Abdominal Pain
;
Appendicitis
;
Appendix
;
Checklist*
;
Cholecystitis, Acute
;
Colitis
;
Diagnosis
;
Emergencies*
;
Emergency Service, Hospital*
;
Gallbladder
;
Humans
;
Intestine, Large
;
Liver
;
Liver Cirrhosis
;
Medical Records
;
Methods
;
Rare Diseases
;
Retrospective Studies
;
Tomography, X-Ray Computed
;
Urinary Calculi
3.Diagnostic performance of the modified Korean Thyroid Imaging Reporting and Data System for thyroid malignancy according to nodule size: a comparison with five society guidelines
Dong Gyu NA ; Wooyul PAIK ; Jaehyung CHA ; Hye Yun GWON ; Suh Young KIM ; Roh-Eul YOO
Ultrasonography 2021;40(4):474-485
Purpose:
The aim of this study was to evaluate the diagnostic performance of the modified Korean Thyroid Imaging Reporting and Data System (K-TIRADS) compared with five society risk stratification systems (RSSs) according to nodule size.
Methods:
In total, 3,826 consecutive thyroid nodules (≥1 cm) with final diagnoses in 3,088 patients were classified according to five RSSs. The K-TIRADS was modified by raising the biopsy size threshold for low-suspicion nodules and subcategorizing intermediate-suspicion nodules. We assessed the performance of the RSSs as triage tests and their diagnostic accuracy according to nodule size (with a threshold of 2 cm).
Results:
Of all nodules, 3,277 (85.7%) were benign and 549 (14.3%) were malignant. In small thyroid nodules (≤2 cm), the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) had the highest reduction rate of unnecessary biopsies (76.3%) and the lowest sensitivity (76.1%). The modified K-TIRADS had the second highest reduction rate of unnecessary biopsies (67.6%) and sensitivity (86.6%). The modified K-TIRADS and ACR TI-RADS had the highest diagnostic odds ratios (P=0.165) and the highest areas under the curve (P=0.315). In large nodules (>2 cm), the sensitivity of the ACR TI-RADS for malignancy was significantly lower (88.8%) than the sensitivities of the modified K-TIRADS and other RSSs, which were very high (98.7%-99.3%) (P<0.001).
Conclusion
The modified K-TIRADS allows a large proportion of unnecessary biopsies to be avoided, while maintaining high sensitivity and diagnostic accuracy for small malignant tumors and very high sensitivity for large malignant tumors.
4.Accuracy of Model-Based Iterative Reconstruction for CT Volumetry of Part-Solid Nodules and Solid Nodules in Comparison with Filtered Back Projection and Hybrid Iterative Reconstruction at Various Dose Settings: An Anthropomorphic Chest Phantom Study
Seung Kwan KIM ; Cherry KIM ; Ki Yeol LEE ; Jaehyung CHA ; Hyun ju LIM ; Eun Young KANG ; Yu Whan OH
Korean Journal of Radiology 2019;20(7):1195-1206
OBJECTIVE: To investigate the accuracy of model-based iterative reconstruction (MIR) for volume measurement of part-solid nodules (PSNs) and solid nodules (SNs) in comparison with filtered back projection (FBP) or hybrid iterative reconstruction (HIR) at various radiation dose settings. MATERIALS AND METHODS: CT scanning was performed for eight different diameters of PSNs and SNs placed in the phantom at five radiation dose levels (120 kVp/100 mAs, 120 kVp/50 mAs, 120 kVp/20 mAs, 120 kVp/10 mAs, and 80 kVp/10 mAs). Each CT scan was reconstructed using FBP, HIR, or MIR with three different image definitions (body routine level 1 [IMR-R1], body soft tissue level 1 [IMR-ST1], and sharp plus level 1 [IMR-SP1]; Philips Healthcare). The SN and PSN volumes including each solid/ground-glass opacity portion were measured semi-automatically, after which absolute percentage measurement errors (APEs) of the measured volumes were calculated. Image noise was calculated to assess the image quality. RESULTS: Across all nodules and dose settings, the APEs were significantly lower in MIR than in FBP and HIR (all p < 0.01). The APEs of the smallest inner solid portion of the PSNs (3 mm) and SNs (3 mm) were the lowest when MIR (IMR-R1 and IMR-ST1) was used for reconstruction for all radiation dose settings. (IMR-R1 and IMR-ST1 at 120 kVp/100 mAs, 1.06 ± 1.36 and 8.75 ± 3.96, p < 0.001; at 120 kVp/50 mAs, 1.95 ± 1.56 and 5.61 ± 0.85, p = 0.002; at 120 kVp/20 mAs, 2.88 ± 3.68 and 5.75 ± 1.95, p = 0.001; at 120 kVp/10 mAs, 5.57 ± 6.26 and 6.32 ± 2.91, p = 0.091; at 80 kVp/10 mAs, 5.84 ± 1.96 and 6.90 ± 3.31, p = 0.632). Image noise was significantly lower in MIR than in FBP and HIR for all radiation dose settings (120 kVp/100 mAs, 3.22 ± 0.66; 120 kVp/50 mAs, 4.19 ± 1.37; 120 kVp/20 mAs, 5.49 ± 1.16; 120 kVp/10 mAs, 6.88 ± 1.91; 80 kVp/10 mAs, 12.49 ± 6.14; all p < 0.001). CONCLUSION: MIR was the most accurate algorithm for volume measurements of both PSNs and SNs in comparison with FBP and HIR at low-dose as well as standard-dose settings. Specifically, MIR was effective in the volume measurement of the smallest PSNs and SNs.
Hominidae
;
Humans
;
Lung Neoplasms
;
Multidetector Computed Tomography
;
Noise
;
Phantoms, Imaging
;
Radiation Dosage
;
Thorax
;
Tomography, X-Ray Computed
5.Comparison of Filtered Back Projection, Hybrid Iterative Reconstruction, Model-Based Iterative Reconstruction, and Virtual Monoenergetic Reconstruction Images at Both Low- and Standard-Dose Settings in Measurement of Emphysema Volume and Airway Wall Thick.
Cherry KIM ; Ki Yeol LEE ; Chol SHIN ; Eun Young KANG ; Yu Whan OH ; Moin HA ; Chang Sub KO ; Jaehyung CHA
Korean Journal of Radiology 2018;19(4):809-817
OBJECTIVE: To evaluate the accuracy of emphysema volume (EV) and airway measurements (AMs) produced by various iterative reconstruction (IR) algorithms and virtual monoenergetic images (VME) at both low- and standard-dose settings. MATERIALS AND METHODS: Computed tomography (CT) images were obtained on phantom at both low- (30 mAs at 120 kVp) and standard-doses (100 mAs at 120 kVp). Each CT scan was reconstructed using filtered back projection, hybrid IR (iDose4; Philips Healthcare), model-based IR (IMR-R1, IMR-ST1, IMR-SP1; Philips Healthcare), and VME at 70 keV (VME70). The EV of each air column and wall area percentage (WA%) of each airway tube were measured in all algorithms. Absolute percentage measurement errors of EV (APEvol) and AM (APEWA%) were then calculated. RESULTS: Emphysema volume was most accurately measured in IMR-R1 (APEvol in low-dose, 0.053 ± 0.002; APEvol in standard-dose, 0.047 ± 0.003; all p < 0.001) and AM was the most accurate in IMR-SP1 on both low- and standard-doses CT (APEWA% in low-dose, 0.067 ± 0.002; APEWA% in standard-dose, 0.06 ± 0.003; all p < 0.001). There were no significant differences in the APEvol of IMR-R1 between low- and standard-doses (all p > 0.05). VME70 showed a significantly higher APEvol than iDose4, IMR-R1, and IMR-ST1 (all p < 0.004). VME70 also showed a significantly higher APEWA% compared with the other algorithms (all p < 0.001). CONCLUSION: IMR was the most accurate technique for measurement of both EV and airway wall thickness. However, VME70 did not show a significantly better accuracy compared with other algorithms.
Emphysema*
;
Tomography, X-Ray Computed
6.A Prospective Study on the Value of Ultrasound Microflow Assessment to Distinguish Malignant from Benign Solid Breast Masses: Association between Ultrasound Parameters and Histologic Microvessel Densities
Ah Young PARK ; Myoungae KWON ; Ok Hee WOO ; Kyu Ran CHO ; Eun Kyung PARK ; Sang Hoon CHA ; Sung Eun SONG ; Ju Han LEE ; JaeHyung CHA ; Gil Soo SON ; Bo Kyoung SEO
Korean Journal of Radiology 2019;20(5):759-772
OBJECTIVE: To investigate the value of ultrasound (US) microflow assessment in distinguishing malignant from benign solid breast masses as well as the association between US parameters and histologic microvessel density (MVD). MATERIALS AND METHODS: Ninety-eight breast masses (57 benign and 41 malignant) were examined using Superb Microvascular Imaging (SMI) and contrast-enhanced US (CEUS) before biopsy. Two radiologists evaluated the quantitative and qualitative vascular parameters on SMI (vascular index, morphology, distribution, and penetration) and CEUS (time-intensity curve analysis and enhancement characteristics). US parameters were compared between benign and malignant masses and the diagnostic performance was compared between SMI and CEUS. Subgroup analysis was performed according to lesion size. The effect of vascular parameters on downgrading Breast Imaging Reporting and Data System (BI-RADS) category 4A masses was evaluated. The association between histologic MVD and US parameters was analyzed. RESULTS: Malignant masses were associated with a higher vascular index (15.1 ± 7.3 vs. 5.9 ± 5.6), complex vessel morphology (82.9% vs. 42.1%), central vascularity (95.1% vs. 59.6%), penetrating vessels (80.5% vs. 31.6%) on SMI (all, p < 0.001), as well as higher peak intensity (37.1 ± 25.7 vs. 17.0 ± 15.8, p < 0.001), slope (10.6 ± 11.2 vs. 3.9 ± 4.2, p = 0.001), area (1035.7 ± 726.9 vs. 458.2 ± 410.2, p < 0.001), hyperenhancement (95.1% vs. 70.2%, p = 0.005), centripetal enhancement (70.7% vs. 45.6%, p = 0.023), penetrating vessels (65.9% vs. 22.8%, p < 0.001), and perfusion defects (31.7% vs. 3.5%, p < 0.001) on CEUS (p ≤ 0.023). The areas under the receiver operating characteristic curve (AUCs) of SMI and CEUS were 0.853 and 0.841, respectively (p = 0.803). In 19 masses measuring < 10 mm, central vascularity on SMI was associated with malignancy (100% vs. 38.5%, p = 0.018). Considering all benign SMI parameters on the BI-RADS assessment, unnecessary biopsies could be avoided in 12 category 4A masses with improved AUCs (0.500 vs. 0.605, p < 0.001). US vascular parameters associated with malignancy showed higher MVD (p ≤ 0.016). MVD was higher in malignant masses than in benign masses, and malignant masses negative for estrogen receptor or positive for Ki67 had higher MVD (p < 0.05). CONCLUSION: US microflow assessment using SMI and CEUS is valuable in distinguishing malignant from benign solid breast masses, and US vascular parameters are associated with histologic MVD.
Area Under Curve
;
Biopsy
;
Breast Neoplasms
;
Breast
;
Estrogens
;
Information Systems
;
Microvessels
;
Perfusion
;
Prospective Studies
;
ROC Curve
;
Ultrasonography
7.Semi-Quantitative Scoring of Late Gadolinium Enhancement of the Left Ventricle in Patients with Ischemic Cardiomyopathy: Improving Interobserver Reliability and Agreement Using Consensus Guidance from the Asian Society of Cardiovascular Imaging-Practical Tutorial (ASCI-PT) 2020
Cherry KIM ; Chul Hwan PARK ; Do Yeon KIM ; Jaehyung CHA ; Bae Young LEE ; Chan Ho PARK ; Eun-Ju KANG ; Hyun Jung KOO ; Kakuya KITAGAWA ; Min Jae CHA ; Rungroj KRITTAYAPHONG ; Sang Il CHOI ; Sanjaya VISWAMITRA ; Sung Min KO ; Sung Mok KIM ; Sung Ho HWANG ; Nguyen Ngoc TRANG ; Whal LEE ; Young Jin KIM ; Jongmin LEE ; Dong Hyun YANG
Korean Journal of Radiology 2022;23(3):298-307
Objective:
This study aimed to evaluate the effect of implementing the consensus statement from the Asian Society of Cardiovascular Imaging-Practical Tutorial 2020 (ASCI-PT 2020) on the reliability of cardiac MR with late gadolinium enhancement (CMR-LGE) myocardial viability scoring between observers in the context of ischemic cardiomyopathy.
Materials and Methods:
A total of 17 cardiovascular imaging experts from five different countries evaluated CMR obtained in 26 patients (male:female, 23:3; median age [interquartile range], 55.5 years [50–61.8]) with ischemic cardiomyopathy. For LGE scoring, based on the 17 segments, the extent of LGE in each segment was graded using a five-point scoring system ranging from 0 to 4 before and after exposure according to the consensus statement. All scoring was performed via webbased review. Scores for slices, vascular territories, and total scores were obtained as the sum of the relevant segmental scores. Interobserver reliability for segment scores was assessed using Fleiss’ kappa, while the intraclass correlation coefficient (ICC) was used for slice score, vascular territory score, and total score. Inter-observer agreement was assessed using the limits of agreement from the mean (LoA).
Results:
Interobserver reliability (Fleiss’ kappa) in each segment ranged 0.242–0.662 before the consensus and increased to 0.301–0.774 after the consensus. The interobserver reliability (ICC) for each slice, each vascular territory, and total score increased after the consensus (slice, 0.728–0.805 and 0.849–0.884; vascular territory, 0.756–0.902 and 0.852–0.941; total score, 0.847 and 0.913, before and after implementing the consensus statement, respectively. Interobserver agreement in scoring also improved with the implementation of the consensus for all slices, vascular territories, and total score. The LoA for the total score narrowed from ± 10.36 points to ± 7.12 points.
Conclusion
The interobserver reliability and agreement for CMR-LGE scoring for ischemic cardiomyopathy improved when following guidance from the ASCI-PT 2020 consensus statement.