1.Association between sleep duration and impaired fasting glucose according to work type in non-regular workers: data from the first and second year (2016, 2017) of the 7th Korean National Health and Nutrition Examination (KNHANE) (a cross-sectional study)
JaeHan JOO ; Jae-Gwang LEE ; SangWoo KIM ; JaeHan LEE ; June-Hee LEE ; Kyung-Jae LEE
Annals of Occupational and Environmental Medicine 2020;32(1):e29-
Background:
We aimed to find the relationship between sleep duration and impaired fasting glucose according to working type in non-regular workers using the 2016 and 2017 Korean National Health And Nutrition Examination (KNHANE, 7th revision).Method: In the 1st and 2nd year (2016, 2017) of the 7th KNHANE, 16,277 people participated. Minors were excluded because this study was intended for individuals aged 19 years and older.As this study was based on wage workers, unemployment, self-employed workers, employers, unpaid family workers, and those who have insufficient answers such as unknown or no response were excluded. Regular workers were excluded because this study was intended for non-regular workers. Finally, a total of 2,168 people were included in the survey, except those who had been diagnosed with diabetes, had a fasting blood glucose level of 126 mg/dL or higher, or taking hypoglycemic agents or receiving insulin injections. To find the relationship between sleep duration and impaired fasting glucose according to work type in non-regular workers, multiple logistic regression analysis was performed by adjusting the general and occupational characteristics after stratification according to work type. All statistical analyses were performed using the SPSS software (version 26.0; SPSS Inc., Chicago, IL, USA).
Results:
In the case of insufficient sleep duration in irregular female workers, the odds ratio (OR) of impaired fasting glucose was statistically insignificant, but in the case of insufficient sleep duration in irregular male workers who have shift work, the odds ratio (OR) of impaired fasting glucose was significantly higher than that of sufficient sleep duration (Model 1, OR: 3.05, 95% confidence interval [CI]: 1.18–7.90; Model 2, OR: 2.81, 95% CI: 1.08–7.29).
Conclusions
Our findings demonstrate that insufficient sleep duration was associated with an increase in fasting blood glucose levels in non-regular male workers working shifts. This means that non-regular workers are in desperate need for adequate sleep and health care. We hope that our study will help improve the health of non-regular workers and more systematic and prospective follow-up studies will be conducted to further improve the health of nonregular workers.
2.Association between sleep duration and impaired fasting glucose according to work type in non-regular workers: data from the first and second year (2016, 2017) of the 7th Korean National Health and Nutrition Examination (KNHANE) (a cross-sectional study)
JaeHan JOO ; Jae-Gwang LEE ; SangWoo KIM ; JaeHan LEE ; June-Hee LEE ; Kyung-Jae LEE
Annals of Occupational and Environmental Medicine 2020;32(1):e29-
Background:
We aimed to find the relationship between sleep duration and impaired fasting glucose according to working type in non-regular workers using the 2016 and 2017 Korean National Health And Nutrition Examination (KNHANE, 7th revision).Method: In the 1st and 2nd year (2016, 2017) of the 7th KNHANE, 16,277 people participated. Minors were excluded because this study was intended for individuals aged 19 years and older.As this study was based on wage workers, unemployment, self-employed workers, employers, unpaid family workers, and those who have insufficient answers such as unknown or no response were excluded. Regular workers were excluded because this study was intended for non-regular workers. Finally, a total of 2,168 people were included in the survey, except those who had been diagnosed with diabetes, had a fasting blood glucose level of 126 mg/dL or higher, or taking hypoglycemic agents or receiving insulin injections. To find the relationship between sleep duration and impaired fasting glucose according to work type in non-regular workers, multiple logistic regression analysis was performed by adjusting the general and occupational characteristics after stratification according to work type. All statistical analyses were performed using the SPSS software (version 26.0; SPSS Inc., Chicago, IL, USA).
Results:
In the case of insufficient sleep duration in irregular female workers, the odds ratio (OR) of impaired fasting glucose was statistically insignificant, but in the case of insufficient sleep duration in irregular male workers who have shift work, the odds ratio (OR) of impaired fasting glucose was significantly higher than that of sufficient sleep duration (Model 1, OR: 3.05, 95% confidence interval [CI]: 1.18–7.90; Model 2, OR: 2.81, 95% CI: 1.08–7.29).
Conclusions
Our findings demonstrate that insufficient sleep duration was associated with an increase in fasting blood glucose levels in non-regular male workers working shifts. This means that non-regular workers are in desperate need for adequate sleep and health care. We hope that our study will help improve the health of non-regular workers and more systematic and prospective follow-up studies will be conducted to further improve the health of nonregular workers.
3.Temporal Trends of Cardiac Implantable Electronic Device Implantations: a Nationwide Population-based Study
Ji Hyun LEE ; So Ryoung LEE ; Eue Keun CHOI ; Jaehan JEONG ; Hyung Deuk PARK ; So Jeong YOU ; Sang Soo LEE ; Seil OH
Korean Circulation Journal 2019;49(9):841-852
BACKGROUND AND OBJECTIVES: Implantation of cardiac implantable electronic devices (CIED), including permanent pacemakers (PM), implantable cardioverter-defibrillators (ICD), and cardiac resynchronization therapy (CRT) devices, has increased significantly over the past several years. However, limited data exists regarding temporal trends of CIED implantations in Asian population. This study aimed to investigate temporal trends of CIED treatment in Korea. METHODS: Using the National Health Insurance Service database of the entire Korean adult population, temporal trends of CIED procedures between 2009 and 2016 were evaluated. Additionally, temporal changes in the prevalence of patients' comorbidities were evaluated. RESULTS: A total of 35,421 CIED procedures (new implantations: 27,771, replacements: 7,650) were performed during the study period. The mean age of new CIED recipients and the prevalence of comorbidities, including hypertension, diabetes mellitus, heart failure, stroke, and atrial fibrillation, increased substantially with time. Compared to 2009, the number of new implantations of PM, ICD, and CRT devices increased by 2.0 (1,977 to 3,910), 3.6 (230 to 822), and 4.9 (44 to 217) times in 2016, respectively. The annual new implantation rate of CIED also increased accordingly (5.1 to 9.3 for PM, 0.6 to 1.9 for ICD, and 0.1 to 0.5 for CRT devices, per 100,000 persons). CONCLUSIONS: The number of CIED implantation increased substantially from 2009 to 2016 in Korea. Also, the patients with CIED have been changed to be older and have more comorbidities. Therefore, the burden of health care cost in patients with CIED would be expected to increase in the future.
Adult
;
Asian Continental Ancestry Group
;
Atrial Fibrillation
;
Cardiac Resynchronization Therapy
;
Comorbidity
;
Defibrillators, Implantable
;
Diabetes Mellitus
;
Epidemiology
;
Health Care Costs
;
Heart Failure
;
Humans
;
Hypertension
;
Korea
;
National Health Programs
;
Pacemaker, Artificial
;
Prevalence
;
Stroke
4.Temporal Trends of Cardiac Implantable Electronic Device Implantations: a Nationwide Population-based Study
Ji Hyun LEE ; So Ryoung LEE ; Eue Keun CHOI ; Jaehan JEONG ; Hyung Deuk PARK ; So Jeong YOU ; Sang Soo LEE ; Seil OH
Korean Circulation Journal 2019;49(9):841-852
BACKGROUND AND OBJECTIVES:
Implantation of cardiac implantable electronic devices (CIED), including permanent pacemakers (PM), implantable cardioverter-defibrillators (ICD), and cardiac resynchronization therapy (CRT) devices, has increased significantly over the past several years. However, limited data exists regarding temporal trends of CIED implantations in Asian population. This study aimed to investigate temporal trends of CIED treatment in Korea.
METHODS:
Using the National Health Insurance Service database of the entire Korean adult population, temporal trends of CIED procedures between 2009 and 2016 were evaluated. Additionally, temporal changes in the prevalence of patients' comorbidities were evaluated.
RESULTS:
A total of 35,421 CIED procedures (new implantations: 27,771, replacements: 7,650) were performed during the study period. The mean age of new CIED recipients and the prevalence of comorbidities, including hypertension, diabetes mellitus, heart failure, stroke, and atrial fibrillation, increased substantially with time. Compared to 2009, the number of new implantations of PM, ICD, and CRT devices increased by 2.0 (1,977 to 3,910), 3.6 (230 to 822), and 4.9 (44 to 217) times in 2016, respectively. The annual new implantation rate of CIED also increased accordingly (5.1 to 9.3 for PM, 0.6 to 1.9 for ICD, and 0.1 to 0.5 for CRT devices, per 100,000 persons).
CONCLUSIONS
The number of CIED implantation increased substantially from 2009 to 2016 in Korea. Also, the patients with CIED have been changed to be older and have more comorbidities. Therefore, the burden of health care cost in patients with CIED would be expected to increase in the future.
5.The Burden and Risk Factors for Infection of Transvenous Cardiovascular Implantable Electronic Device: a Nationwide Cohort Study
Pil Sung YANG ; Jaehan JEONG ; So Jeong YOU ; Hee Tae YU ; Tae Hoon KIM ; Jung Hoon SUNG ; Sang Soo LEE ; Hyung Deuk PARK ; Boyoung JOUNG
Korean Circulation Journal 2019;49(8):742-752
BACKGROUND AND OBJECTIVES: There are limited published data on the incidence and cost associated with cardiac implantable electrical device (CIED) infection for Asian patients. We analyzed the infection burden associated with the implantation of CIEDs in Korea. METHODS: In the Health Insurance Review & Assessment Service (HIRA) database during the period from January 1, 2014 to December 31, 2016, we identified 16,908 patients with CIED implantation. CIED infection was defined as either: 1) Infection-related diagnosis code by the Korean Standard Classification of Diseases after any CIED procedure; or 2) CIED removal along with systemic infection. RESULTS: The proportions of first implantation and replacement were 77.6% and 22.4%, respectively. During the follow-up period of 17.1±10.6 months, a total of 462 patients had CIED infection with incidence of 1.95 per 100 person-years with higher infection rate in replacement than first implantation (3.97 vs. 1.4 per 100 person-years, p<0.001). The average cost per person was US$ 16,584 (pacemaker, $13,736; implantable cardioverter defibrillator, $28,402; cardiac resynchronization therapy, $29,674). The risk factors of CIED infection were generator replacement (adjusted hazard ratio [aHR], 3.14; 95% confidence interval [CI], 2.60–3.78), diabetes mellitus (aHR, 1.94; 95% CI, 1.58–2.38), and congestive heart failure (aHR, 1.86; 95% CI, 1.51–2.28). CONCLUSIONS: The rate of CIED infection in Korea was 1.95 per 100 person-years with average cost of US$ 16,584. The most important risk factor was generator replacement. This result suggests that generator replacement should be performed cautiously to avoid CIED infection.
Asian Continental Ancestry Group
;
Cardiac Resynchronization Therapy
;
Classification
;
Cohort Studies
;
Defibrillators
;
Defibrillators, Implantable
;
Diabetes Mellitus
;
Diagnosis
;
Follow-Up Studies
;
Heart Failure
;
Humans
;
Incidence
;
Insurance, Health
;
Korea
;
Risk Factors
6.The Burden and Risk Factors for Infection of Transvenous Cardiovascular Implantable Electronic Device: a Nationwide Cohort Study
Pil Sung YANG ; Jaehan JEONG ; So Jeong YOU ; Hee Tae YU ; Tae Hoon KIM ; Jung Hoon SUNG ; Sang Soo LEE ; Hyung Deuk PARK ; Boyoung JOUNG
Korean Circulation Journal 2019;49(8):742-752
BACKGROUND AND OBJECTIVES:
There are limited published data on the incidence and cost associated with cardiac implantable electrical device (CIED) infection for Asian patients. We analyzed the infection burden associated with the implantation of CIEDs in Korea.
METHODS:
In the Health Insurance Review & Assessment Service (HIRA) database during the period from January 1, 2014 to December 31, 2016, we identified 16,908 patients with CIED implantation. CIED infection was defined as either: 1) Infection-related diagnosis code by the Korean Standard Classification of Diseases after any CIED procedure; or 2) CIED removal along with systemic infection.
RESULTS:
The proportions of first implantation and replacement were 77.6% and 22.4%, respectively. During the follow-up period of 17.1±10.6 months, a total of 462 patients had CIED infection with incidence of 1.95 per 100 person-years with higher infection rate in replacement than first implantation (3.97 vs. 1.4 per 100 person-years, p<0.001). The average cost per person was US$ 16,584 (pacemaker, $13,736; implantable cardioverter defibrillator, $28,402; cardiac resynchronization therapy, $29,674). The risk factors of CIED infection were generator replacement (adjusted hazard ratio [aHR], 3.14; 95% confidence interval [CI], 2.60–3.78), diabetes mellitus (aHR, 1.94; 95% CI, 1.58–2.38), and congestive heart failure (aHR, 1.86; 95% CI, 1.51–2.28).
CONCLUSIONS
The rate of CIED infection in Korea was 1.95 per 100 person-years with average cost of US$ 16,584. The most important risk factor was generator replacement. This result suggests that generator replacement should be performed cautiously to avoid CIED infection.
7.Enhanced Bone Formation by Rapidly Formed Bony Wall over the Bone Defect Using Dual Growth Factors
Jaehan PARK ; Narae JUNG ; Dong-Joon LEE ; Seunghan OH ; Sungtae KIM ; Sung-Won CHO ; Jong-Eun KIM ; Hong Seok MOON ; Young-Bum PARK
Tissue Engineering and Regenerative Medicine 2023;20(5):767-778
BACKGROUND:
In guided bone regeneration (GBR), there are various problems that occur in the bone defect after the wound healing period. This study aimed to investigate the enhancement of the osteogenic ability of the dual scaffold complex and identify the appropriate concentration of growth factors (GF) for new bone formation based on the novel GBR concept that is applying rapid bone forming GFs to the membrane outside of the bone defect.
METHODS:
Four bone defects with a diameter of 8 mm were formed in the calvaria of New Zealand white rabbits each to perform GBR. Collagen membrane and biphasic calcium phosphate (BCP) were applied to the bone defects with the four different concetration of BMP-2 or FGF-2. After 2, 4, and 8 weeks of healing, histological, histomorphometric, and immunohistochemical analyses were conducted.
RESULTS:
In the histological analysis, continuous forms of new bones were observed in the upper part of bone defect in the experimental groups, whereas no continuous forms were observed in the control group. In the histomorphometry, The group to which BMP-2 0.5 mg/ml and FGF-2 1.0 mg/ml was applied showed statistically significantly higher new bone formation. Also, the new bone formation according to the healing period was statistically significantly higher at 8 weeks than at 2, 4 weeks.
CONCLUSION
The novel GBR method in which BMP-2, newly proposed in this study, is applied to the membrane is effective for bone regeneration. In addition, the dual scaffold complex is quantitatively and qualitatively advantageous for bone regeneration and bone maintenance over time.