1.Correlation of anxiety and depression with coping strategy in hemodialysis patients.
Jae Hyung RYU ; Hyung Yung LEE
Journal of Korean Neuropsychiatric Association 1992;31(3):587-594
No abstract available.
Anxiety*
;
Depression*
;
Humans
;
Renal Dialysis*
2.A comparative study on the cognitive dysfunction between paranoid and nonparanoid schizophrenics.
Young Jae SEOL ; Hyung Yung LEE
Journal of Korean Neuropsychiatric Association 1991;30(1):88-97
No abstract available.
3.Identification of the Orchid Mycorrhizal Fungi Isolated from the Roots of Korean Native Orchid.
Mycobiology 2000;28(1):17-26
The orchid symbiotic fungi were isolated from the roots of Korean native orchid (Cymbidium goeringii) collected and Chinese orchid (C. sinense) obtained from greenhouses. They were identified as a species of Rhizoctonia, based on the sequences of 18r rDNA, the microscopic observations of mycelia, and the symbiotic relationships with commercial orchids. The isolate collected from Chinese orchids was revealed to be a species of Ceratobasidium endophytica, and to be different from the other isolates at the thickness of the mycelia stained in the root cells of Korean native orchids. The other isolates collected from the Korean native orchids were considered to be a species of Tulsanella repens (anamorphic: Epulorhiza repens) or its related one. The physiologic or microscopic variations were oftenly observed among them, but the tendency of grouping these in the 18s rDNA sequences were observed to be consistent with those of the localities collected. The further taxonomical segregating for Korean symbiotic fungi was not made because the information concerned were limited in this moment, but was recognized as based on the sequences of 18s DNA.
Asian Continental Ancestry Group
;
DNA
;
DNA, Ribosomal
;
Fungi*
;
Humans
;
Mycorrhizae
;
Rhizoctonia
;
Symbiosis
4.A study on the effect of rotational speeds of the trephine mill on the temperature of surrounding bone during dental implantation procedure and osseointegration of implants.
Jin Geol LEE ; Jae Ho YANG ; Sun Hyung LEE
The Journal of Korean Academy of Prosthodontics 1992;30(2):167-189
No abstract available.
Dental Implantation*
;
Dental Implants*
;
Osseointegration*
5.A Case of Multicystic Renal Dysplasia with Chromosomal Abnormality.
Myung Jae LEE ; Soon In JUNG ; Jae Hyung NA ; Jae Hong KIM ; Jong Jae JUNG
Korean Journal of Perinatology 1999;10(1):56-60
Holoprosencephaly is a rare and complex malformation affecting the cleavage of the developing forebrain and is usually associated with defects of the mid Face. We have experienced a case of holoprosencephaly, diagnosed prenatally by ultrasound examination at 31 weeks of pregnancy in a 31-year-old primigravida woman. This case is characterized by holoprosencephaly, cleft palate, cleft lip, left renal aplasia and right renal hypertrophy. The chromosomal study showed a deletion of the long arm of chromosome 7, 46, XX, del(7)(q32), We report with a terminal deletion of chromosome 7q associated with atypical clinical picture and holoprosencephaly.
Adult
;
Arm
;
Chromosome Aberrations*
;
Chromosomes, Human, Pair 7
;
Cleft Lip
;
Cleft Palate
;
Female
;
Holoprosencephaly
;
Humans
;
Hypertrophy
;
Multicystic Dysplastic Kidney*
;
Pregnancy
;
Prosencephalon
;
Ultrasonography
6.A study on the effects of early loading on the surrounding bone tissue of the dental implants.
Hui Un PARK ; Jae Ho YANG ; Sun Hyung LEE
The Journal of Korean Academy of Prosthodontics 1993;31(1):101-127
No abstract available.
Bone and Bones*
;
Dental Implants*
7.A study on the long-term preservation of artificial skin.
Ho Chul PARK ; Hyung Soo LEE ; Jae Kyung PARK
Journal of the Korean Surgical Society 1993;45(5):618-632
No abstract available.
Skin, Artificial*
8.FRACTURE STRENGTH AND MARGINAL FIT OF IN-CERAM, COPY-MILLED IN-CERAM, AND IPS EMPRESS 2 ALL-CERAMIC BRIDGES.
Jung Won HWANG ; Jae Ho YANG ; Sun Hyung LEE
The Journal of Korean Academy of Prosthodontics 2001;39(6):641-658
All-ceramic restorations have become an attractive alternative to porcelain-fused-to-metal crowns. In-Ceram, and more recently IPS Empress 2 were introduced as a new all-ceramic system for single crowns and 3-unit fixed partial dentures. But their strength and marginal fit are still an important issue. This study evaluated the fracture resistance and marginal fit of three systems of 3 unit all-ceramic bridge fabricated on prepared maxillary anterior resin teeth in vitro. The 3 all-ceramic bridge systems were: (1) a glass-infiltrated, sintered alumina system (In-Ceram) fabricated conventionally, (2) the same system with copy-milled alumina cores (copy-milled In-Ceram), (3) a heat pressed, lithium disilicate reinforced glass-ceramic system (IPS Empress 2). Ten bridges of each system with standardized design of framework were fabricated. All specimens of each system were compressed at 55degree at the palatal surface of pontic until catastrophic fracture occurred. Another seven bridges of each system were fabricated with standard method. All of the bridge-die complexes were embedded in epoxy resin and sectioned buccolingually and mesiodistally. The absolute marginal discrepancy was measured with stereomicroscope at x50 power. The following results were obtained: 1. There was no significant difference in the fracture strength among the 3 systems studied. 2. The Weibull modulus of copy-milled In-Ceram was higher than that of In-Ceram and IPS Empress 2 bridges. 3. Copy-milled In-Ceram (112micrometer) exhibited significantly greater marginal discrepancy than In-Ceram (97micrometer), and IPS Empress 2 (94micrometer at P=0.05. 4. The lingual surfaces of the ceramic crowns showed smaller marginal discrepancies than mesial and distal points. There was no significant difference between teeth (incisor, canine) at P=0.05. 5. All-ceramic bridges of three systems appeared to exhibit sufficient initial strength and acceptable marginal fit values to allow clinical application.
Aluminum Oxide
;
Ceramics
;
Crowns
;
Denture, Partial, Fixed
;
Hot Temperature
;
Lithium
;
Tooth
9.A study on the Heavy Metal Concentrations and Their Interrelationships in Women's Blood and Urine in small towns.
In Dam HWANG ; No Suk KI ; Jae Hyung LEE ; In Seo PARK
Korean Journal of Preventive Medicine 1987;20(1):49-55
The results of this study which had been investigated for the purpose of analyzing heavy metal concentrations in women's blood and urine, their correlation degree and significance of cadmium as indicator of accumulated heavy metals are as follows. 1) In blood, concentrations of Cd, Pb, Cu and Zn are respectively 0.0110+/-0.14 ug/ml, 0.208+/-138 ug/ml, 0.899+/-0.153 ug/ml and 5.432+/-1.020 ug/ml. 2) In urine, concentrations of Cd, Pb, Cu and Zn are respectively 0.003+/-0.12 ug/ml, 0.025+/-0.18 ug/ml, 0.013+/-0.12 ug/ml and 0.277+/-0.192 ug/ml. 3) Correlation coefficients between blood and urine are only significant in Zn (r=0.363, p<0.01). 4) In blood, correlation coefficients of Cd concentration and Pb, Zn are respectively 0.518 (p<0.01). 5) Correlation coefficients between Cd concentration in blood and Pb, Cu and Zn in urine are respectively r=-0.012, r=0.027, r=0.241 (p<0.05), and only Cd concentration and Zn is significant.
Cadmium
;
Metals, Heavy
10.Influence of Thickness of Empress 2 Ceramic on Fracture Strength.
Jung Woo KOH ; Jae Ho YANG ; Sun Hyung LEE
The Journal of Korean Academy of Prosthodontics 2000;38(4):446-460
All ceramic restorations have had a more limited life expectancy than metal ceramic crowns because of their lower strength. The relatively lower strength has limited the use of all-ceramic crowns to the areas where occlusal loads are lower. Therefore many researches have been done to increase the strength of all-ceramic crowns. IPS Empress 2 is a new type of lithium disilicate glass-ceramic with enhanced physical characteristics which has been in use clinically since 1998. Previous researches reported that the flexural strength of all-ceramic material was greater than 300MPa, and all-ceramic crowns can be used in staining or layering technique. The objective of this study was to investigate the influence of the thickness of IPS Empress 2 ceramic on fracture strength. Both staining technique and layering technique was investigated. Vita VMK was used as control. For all three groups, five specimens each of 0.8mm, 1.0mm, 1.4mm, 1.8mm, and 2.2mm thickness (a total of 75 specimens) were prepared. Control group: Vita VMK Porcelain specimens were prepared with dentine ceramic and liquid glazing was done. Group I: IPS Empress 2 were prepared with staining technique and stained twice and glazed once. Group II : IPS Empress 2 were prepared with layering technique and glazed after wash firing. The thickness and diameter of the specimen were measured and controlled after specimen preparation. Biaxial Flexure Test (ASTM Standard F394-78) was adopted as this test method produces results least affected by the edge condition of the specimens. Fracture strength was measured with Instron Universal Testing Machine. Conclusions are as follow : 1. The fracture strength was increase in order of control group, test group I, test group II. 2. Fracture strength of the group I(Empress 2 Staining) was 65.54 N in 0.8mm, 155.2 N in 1.0mm, 233.5 N in 1.44mm, 434.5 N in 1.8mm, and 600.1 N in 2.2mm. 3. Fracture strength of the group II (Empress 2 Layering) was 190.0 N in 0.8mm, 283.5 N in 1.0mm, 437.2 N in 1.4mm, 732.0 N in 1.8mm, and 1115.0 N in 2.2mm. 4. No statistical difference was found in flexural strengths according to thickness in a specified group(p>0.05).
Ceramics*
;
Crowns
;
Dental Porcelain
;
Dentin
;
Fires
;
Life Expectancy
;
Lithium