3.A 20 years, experience with well differentiated thyroid carcinoma in children & teenagers.
Jae Sub PARK ; Seung Hoon CHOI ; Eu Ho HWANG
Journal of the Korean Cancer Association 1991;23(3):640-647
No abstract available.
Adolescent*
;
Child*
;
Humans
;
Thyroid Gland*
;
Thyroid Neoplasms*
4.Foregut Cyst Communicated with Esophagus, Lined by Bronchial Mucosa.
Jae Chun CHANG ; Kil Ho JHO ; Mi Soo HWANG
Yeungnam University Journal of Medicine 1984;1(1):139-144
A case of foregut cyst communicated with esophagus and lined by bronchial mucosa is reviewed and its embryologic base of maldevelopment it discussed. It is not always easy to distinguish between digestive and respiratory cyst in mediastinum. There is whole range of intermediate between a cyst with ciliated and one with squamous or columnar mucosa. Origin of this dysembryoplasia is difficult to determine when on consider that the esophagus is covered with ciliated epithelium until the eleventh week of fetal life and that ciliated growth are found on its wall until the sixth month of the fetal life. And we concluded, general agreement is that cysts which have gastric epithelium in whole or in part, represent a distinct type and should be classified as (gastro) enteric cyst, mediastinal cyst containing cartilage were considered definitely as respiratory (bronchial or bronchogenic) cyst.
Cartilage
;
Epithelium
;
Esophagus*
;
Mediastinal Cyst
;
Mediastinum
;
Mucous Membrane*
5.A comparative histologic study of bone-implant interface to the titanium root formed implants in the Mx, Mn.
Jae Hwang LEE ; Song Ju HUR ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 1991;29(2):35-48
No abstract available.
Titanium*
6.FRACTURE STRENGTH AND MARGINAL FIT OF IN-CERAM, COPY-MILLED IN-CERAM, AND IPS EMPRESS 2 ALL-CERAMIC BRIDGES.
Jung Won HWANG ; Jae Ho YANG ; Sun Hyung LEE
The Journal of Korean Academy of Prosthodontics 2001;39(6):641-658
All-ceramic restorations have become an attractive alternative to porcelain-fused-to-metal crowns. In-Ceram, and more recently IPS Empress 2 were introduced as a new all-ceramic system for single crowns and 3-unit fixed partial dentures. But their strength and marginal fit are still an important issue. This study evaluated the fracture resistance and marginal fit of three systems of 3 unit all-ceramic bridge fabricated on prepared maxillary anterior resin teeth in vitro. The 3 all-ceramic bridge systems were: (1) a glass-infiltrated, sintered alumina system (In-Ceram) fabricated conventionally, (2) the same system with copy-milled alumina cores (copy-milled In-Ceram), (3) a heat pressed, lithium disilicate reinforced glass-ceramic system (IPS Empress 2). Ten bridges of each system with standardized design of framework were fabricated. All specimens of each system were compressed at 55degree at the palatal surface of pontic until catastrophic fracture occurred. Another seven bridges of each system were fabricated with standard method. All of the bridge-die complexes were embedded in epoxy resin and sectioned buccolingually and mesiodistally. The absolute marginal discrepancy was measured with stereomicroscope at x50 power. The following results were obtained: 1. There was no significant difference in the fracture strength among the 3 systems studied. 2. The Weibull modulus of copy-milled In-Ceram was higher than that of In-Ceram and IPS Empress 2 bridges. 3. Copy-milled In-Ceram (112micrometer) exhibited significantly greater marginal discrepancy than In-Ceram (97micrometer), and IPS Empress 2 (94micrometer at P=0.05. 4. The lingual surfaces of the ceramic crowns showed smaller marginal discrepancies than mesial and distal points. There was no significant difference between teeth (incisor, canine) at P=0.05. 5. All-ceramic bridges of three systems appeared to exhibit sufficient initial strength and acceptable marginal fit values to allow clinical application.
Aluminum Oxide
;
Ceramics
;
Crowns
;
Denture, Partial, Fixed
;
Hot Temperature
;
Lithium
;
Tooth
7.Clinical analysis in reconstruction of orbital blow-out fracture using the hydroxyapatite.
Sung Ho HWANG ; Yong Chan BAE ; Jae Yong JEON ; So Min HWANG ; Wook Bae HWANG ; Dong Heon KIM
Journal of the Korean Society of Plastic and Reconstructive Surgeons 1998;25(6):1067-1074
The blow-out fracture can be reconstructed by various autogeneous and alloplastic material. Particulate, nonresorbable hydroxyapatite is currently one of the choice of implant material available for reconstruction of blow-out fracture. Hydroxyapatite is radiopaque ceramic, physically and chemically similar to enamel and cortical bone. It is a biomaterial derived from natural corals to use as a bone graft substitute. And we looked into the clinical usefulness of 2 type of hydroxyapatite with their advantages and disadvantages in reconstruction of blow-out fracture. 183 patients with blow-out fracture who underwent surgical reconstruction with two types of hydroxyapatite from March 1933 to July 1977 have been analyzed the results of surgical reconstructions, and have been followed up for more than a year. And the condition of formerly inserted hydroxyapatite was observed in the patients who needed 2nd surgical reconstruction due to the enophthalmos. The disadvantages of hydroxyapatite are fragility, size and contour limitations. In spite of these demerits, hydroxyapatite can be one of the prospective materials to reconstruct orbital floor. Through the clinical experiences for 5 years, we have not found any of complications of exposure, infection, and foreign body reaction. Low rates of diplopia, limitation of ocular movement, and enophtalmos was observed. Hydroxyapatite was well adherent to adjacent orbital bone in most patients who needed secondary reconstruction for enopthalmos. In conclusion, our study shows that the availability of hydroxyapattite in reconstruction of blow-out fracture is recommendable, with low complication rates. Hydroxyapatite important appears to be well tolerated, and provides useful alloplastic prosthesis with few problems in reconstruction of blow-out fracture.
Anthozoa
;
Ceramics
;
Dental Enamel
;
Diplopia
;
Durapatite*
;
Enophthalmos
;
Foreign-Body Reaction
;
Humans
;
Orbit*
;
Orbital Fractures*
;
Prostheses and Implants
;
Transplants
8.The effect of intravenous ritodrine hydrochloride on premature labor.
Jae Min LEE ; Yong Ho MOON ; Sun Jae HWANG ; Kyoung Hoon LEE ; Tae Ro KWAK
Korean Journal of Obstetrics and Gynecology 1993;36(7):3010-3016
No abstract available.
Female
;
Obstetric Labor, Premature*
;
Pregnancy
;
Ritodrine*
9.Mitral valve operation via extended transseptal approach.
Hark Jei KIM ; Jae Joon HWANG ; Jae Seung SHIN ; Sung Joon JOE ; Young Ho CHOI
The Korean Journal of Thoracic and Cardiovascular Surgery 1993;26(12):909-914
No abstract available.
Mitral Valve*
10.Comparision of the Two Groups between Autologous Bone Chips and Cage as Posterior Lumbar Interbody Fusion in Spondylolisthesis Patients.
Pill Jae SHIN ; Chang Hyun KIM ; Jae Gon MOON ; Ho Kook LEE ; Do Yun HWANG
Journal of Korean Neurosurgical Society 2000;29(4):507-513
No abstract available.
Humans
;
Spondylolisthesis*