1.The value of diagnostic laparoscopy in infertility.
Jae Ie YANG ; Yoo Suk JEONG ; Kyung Suk KANG ; Jae Kyun DOO ; Jong Duck KIM
Korean Journal of Obstetrics and Gynecology 1993;36(7):1800-1807
No abstract available.
Infertility*
;
Laparoscopy*
2.An experimental study on the effectiveness of local spasmolytic agents in microvascular vasospasm.
Jae Hoon KIM ; Won Suk OH ; Yong Bae KIM ; Soon Jae YANG ; Jong Sup PARK
Journal of the Korean Society of Plastic and Reconstructive Surgeons 1992;19(5):724-730
No abstract available.
3.A case of carcinomatous polyarthritis.
Suk In LEE ; Woo Kyung KIM ; Jae Suk JUN ; Kyung Ran BAIK ; Sung Hyun YANG ; Young Joo BANG ; Young Ok SONG
Journal of the Korean Cancer Association 1993;25(2):307-314
No abstract available.
Arthritis*
4.Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns.
Hyun Soon PAK ; Jung Suk HAN ; Jai Bong LEE ; Sung Hun KIM ; Jae Ho YANG
The Journal of Advanced Prosthodontics 2010;2(2):33-38
PURPOSE: Marginal fit is a very important factor considering the restoration's long-term success. However, adding porcelain to copings can cause distortion and lead to an inadequate fit which exposes more luting material to the oral environment and causes secondary caries. The purpose of this study was to compare the marginal fit of 2 different all-ceramic crown systems before and after porcelain veneering. This study was also intended to verify the marginal fit of crowns originated from green machining of partially sintered blocks of zirconia (Lava CAD/CAM system) and that of crowns obtained through machining of fully sintered blocks of zirconia (Digident CAD/CAM system). MATERIAL AND METHODS: 20 crowns were made per each system and the marginal fit was evaluated through a light microscope with image processing (Accura 2000) at 50 points that were randomly selected. Each crown was measured twice: the first measurement was done after obtaining a 0.5 mm coping and the second measurement was done after porcelain veneering. The means and standard deviations were calculated and statistical inferences among the 2 groups were made using independent t-test and within the same group through paired t-test. RESULTS: The means and standard deviations of the marginal fit were 61.52 +/- 2.88 micrometer for the Digident CAD/CAM zirconia ceramic crowns before porcelain veneering and 83.15 +/- 3.51 micrometer after porcelain veneering. Lava CAD/CAM zirconia ceramic crowns showed means and standard deviations of 62.22 +/- 1.78 micrometer before porcelain veneering and 82.03 +/- 1.85 micrometer after porcelain veneering. Both groups showed significant differences when analyzing the marginal gaps before and after porcelain veneering within each group. However, no significant differences were found when comparing the marginal gaps of each group before porcelain veneering and after porcelain veneering as well. CONCLUSION: The 2 all-ceramic crown systems showed marginal gaps that were within a reported clinically acceptable range of marginal discrepancy.
Ceramics
;
Crowns
;
Dental Porcelain
;
Light
;
Zirconium
5.FRACTURE TOUGHNESS OF VARIOUS CORE MATERIALS.
Shin Won LEE ; Sun Hyung LEE ; Jae Ho YANG ; Jung Suk HAN ; Jai Bong LEE
The Journal of Korean Academy of Prosthodontics 2001;39(6):682-697
This investigation evaluated the fracture toughness (KIC) of eight currently available core materials, and relate the fracture toughness value to fractography analysis and surface characteristics using a atomic force microscope (AFM). Single-edge notched (SEN) test specimens (n=10) and compact tension (CT) test specimens (n=10) were prepared conforming to the ASTM Standard E-399 for a high copper amalgam, three composite core materials (Core-Max II, Core Paste, Bisfil Core), two reinforced composite core materials (Ti-Core, Ti-Core Natural), a resin-modified glass ionomer core material (Vitremer), and a conventional glass ionomer core material (Ketac-Molar). The specimens were tested with an Instron Universal Testing Machine. The maximum loads were measured to calculate the fracture toughness (KIC). Thereafter, fracture surfaces of SEN specimens of each material were investigated for fractography analysis using scanning electron microscope. And, disc-shaped specimens with 1mm thickness were fabricated for each material and were investigated under AFM for surface morphology analysis. The results were as follows : 1. Bisfil Core showed the highest mean fracture toughness regardless of test methods. 2. For the tooth-colored materials, Ti-Core Natural exhibited the highest fracture toughness. 3. Ketac Molar showed a significantly low fracture toughness when compared with the amalgam and the composite resin core materials (p<0.05). 4. The fracture toughness values obtained with the single-edge notched test, except Ketac Molar, were higher than those obtained in the compact tension test. 5. SEM revealed that the fracture surface of high fracture toughness material was rougher than that of low fracture toughness material. 6. AFM revealed that the surface particles of the composite resins were smaller in size, with a lower surface roughness than the glass ionomer core materials.
Composite Resins
;
Copper
;
Glass
;
Molar
6.Prenatal Cytogenetic Diagnosis with Fetal Ascitic Fluid as a Rapid Chromosome Analysis.
Jeong In YANG ; Kie Suk OH ; Haeng Soo KIM ; Eun Joo AHN ; Jae Sun SHIM
Korean Journal of Obstetrics and Gynecology 1998;41(12):2997-3000
OBJECTIVE: The goal of this study is to determine the efficacy of rapid karyotyping from fetal ascitic fluid. METHODS: In three cases of isolated fetal ascites diagnosed by prenatal ultrasonography, ultrasound guided fetal paracentesis and amniocentesis were performed and successfully obtained. Fetal karyotyping in each case at 29, 30 and 32 weeks gestation using modified lymphocyte culture method was conducted. RESULTS: The chromosomal analysis was successful within 72 hours and abnormalities were detected in two cases and revealed trisomy 21 in each case. Our study demonstrated that the majority distribution of white blood cells was lymphocytes which ranged from 2.1 * 10(6) cells/ml to 3.7 * 10(6) cells/ml and the cell density for culture was at least than 0.35 * 10(6) cells/ml. CONCLUSION: The use of ascitic fluid as a cell source to achieve rapid fetal karyotyping can be valuable when cordocenteis or amniocentesis would be technically more difficult, or when rapid result is required for planning of perinatal management at late second or third trimester gestational age.
Amniocentesis
;
Ascites
;
Ascitic Fluid*
;
Cell Count
;
Cytogenetics*
;
Diagnosis*
;
Down Syndrome
;
Female
;
Gestational Age
;
Humans
;
Karyotyping
;
Leukocytes
;
Lymphocytes
;
Paracentesis
;
Pregnancy
;
Pregnancy Trimester, Third
;
Ultrasonography
;
Ultrasonography, Prenatal
7.The effect of low temperature aging on the mechanical property & phase stability of Y-TZP ceramics.
Hyung Tae KIM ; Jung Suk HAN ; Jae Ho YANG ; Jai Bong LEE ; Sung Hun KIM
The Journal of Advanced Prosthodontics 2009;1(3):113-117
STATEMENT OF PROBLEM: Recently Yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) has been introduced due to superior flexural strength and fracture toughness compared to other dental ceramic systems. Although zirconia has outstanding mechanical properties, the phenomenon of decrease in the life-time of zirconia resulted from degradation in flexural strength after low temperature aging has been reported. PURPOSE: The objective of this study was to investigate degradation of flexural strength of Y-TZP ceramics after various low temperature aging treatments and to evaluate the phase stability and micro-structural change after aging by using X-ray diffraction analysis and a scanning electron microscope (SEM). MATERIAL AND METHODS: Y-TZP blocks of Vita In-Ceram YZ (Vita Zahnfabrik, Bad Sackingen, Germany) were prepared in 40 mm (length) x 4 mm (width) x 3 mm (height) samples. Specimens were artificially aged in distilled water by heat-treatment at a temperature of 75, 100, 125, 150, 175, 200, and 225degrees C for 10 hours, in order to induce the phase transformation at the surface. To measure the mechanical property, the specimens were subjected to a four-point bending test using a universal testing machine (Instron model 3365; Instron, Canton, Mass, USA). In addition, X-ray diffraction analysis (DMAX 2500; Rigaku, Tokyo, Japan) and SEM (Hitachi s4700; Jeol Ltd, Tokyo, Japan) were performed to estimate the phase transformation. The statistical analysis was done using SAS 9.1.3 (SAS institute, USA). The flexural strength data of the experimental groups were analyzed by one-way analysis of variance and to detect statistically significant differences (alpha= .05). RESULTS: The mean flexural strength of sintered Vita In-Ceram YZ without autoclaving was 798 MPa. When applied aging temperature at below 125degrees C for 10 hours, the flexural strength of Vita In-Ceram YZ increased up to 1,161 MPa. However, at above 150degrees C, the flexural strength started to decrease. Although low temperature aging caused the tetragonal-to-monoclinic phase transformation related to temperature, the minimum flexural strength was above 700 MPa. CONCLUSION: The monoclinic phase started to appear after aging treatment above 100degrees C. With the higher aging temperature, the fraction of monoclinic phase increased. The ratio of monoclinic/tetragonal + monoclinic phase reached a plateau value, circa 75% above 175degrees C. The point of monoclinic concentration at which the flexural strength begins to decrease was between 12% and 54%.
Aged
;
Aging
;
Aluminum Oxide
;
Ceramics
;
Collodion
;
Dental Porcelain
;
Electrons
;
Humans
;
Phenothiazines
;
Tokyo
;
Water
;
X-Ray Diffraction
;
Yttrium
;
Zirconium
8.Comparison of polymer-based temporary crown and fixed partial denture materials by diametral tensile strength.
Seung Ryong HA ; Jae Ho YANG ; Jai Bong LEE ; Jung Suk HAN ; Sung Hun KIM
The Journal of Advanced Prosthodontics 2010;2(1):14-17
PURPOSE: The purpose of this study was to investigate the diametral tensile strength of polymer-based temporary crown and fixed partial denture (FPD) materials, and the change of the diametral tensile strength with time. MATERIAL AND METHODS: One monomethacrylate-based temporary crown and FPD material (Trim) and three dimethacrylate-based ones (Protemp 3 Garant, Temphase, Luxtemp) were investigated. 20 specimens (the empty set 4 mm x 6 mm) were fabricated and randomly divided into two groups (Group I: Immediately, Group II: 1 hour) according to the measurement time after completion of mixing. Universal Testing Machine was used to load the specimens at a cross-head speed of 0.5 mm/min. The data were analyzed using one-way ANOVA, the multiple comparison Scheffe test and independent sample t test (alpha = 0.05). RESULTS: Trim showed severe permanent deformation without an obvious fracture during loading at both times. There were statistically significant differences among the dimethacrylate-based materials. The dimethacrylate-based materials presented an increase in strength from 5 minutes to 1 hour and were as follows: Protemp 3 Garant (23.16 - 37.6 MPa), Temphase (22.27 - 28.08 MPa), Luxatemp (14.46 - 20.59 MPa). Protemp 3 Garant showed the highest value. CONCLUSION: The dimethacrylate-based temporary materials tested were stronger in diametral tensile strength than the monomethacrylate-based one. The diametral tensile strength of the materials investigated increased with time.
Acrylic Resins
;
Bisphenol A-Glycidyl Methacrylate
;
Collodion
;
Composite Resins
;
Crowns
;
Denture, Partial, Fixed
;
Methacrylates
;
Polymethacrylic Acids
;
Tensile Strength
9.A study on the fracture strength of collarless metal-ceramic fixed partial dentures.
Jong Wook YOON ; Sung Hun KIM ; Jai Bong LEE ; Jung Suk HAN ; Jae Ho YANG
The Journal of Advanced Prosthodontics 2010;2(4):134-141
PURPOSE: The objective of this study was to evaluate fracture strength of collarless metal-ceramic FPDs according to their metal coping designs. MATERIALS AND METHODS: Four different facial margin design groups were investigated. Group A was a coping with a thin facial metal collar, group B was a collarless coping with its facial metal to the shoulder, group C was a collarless coping with its facial metal 1 mm short of the shoulder, and group D was a collarless coping with its facial metal 2 mm short of the shoulder. Fifteen 3-unit collarless metal-ceramic FPDs were fabricated in each group. Finished FPDs were cemented to PBT (Polybutylene terephthalate) dies with resin cement. The fracture strength test was carried out using universal testing machine (Instron 4465, Instron Co., Norwood MA, USA) at a cross head speed of 0.5 mm/min. Aluminum foil folded to about 1 mm of thickness was inserted between the plunger tip and the incisal edge of the pontic. Vertical load was applied until catastrophic porcelain fracture occurred. RESULTS: The greater the bulk of unsupported facial shoulder porcelain was, the lower the fracture strength became. However, there were no significant differences between experimental groups (P > .05). CONCLUSION: All groups of collarless metal-ceramic FPDs had higher fracture strength than maximum incisive biting force. Modified collarless metal-ceramic FPD can be an alternative to all-ceramic FPDs in clinical situations.
Aluminum
;
Bites and Stings
;
Collodion
;
Dental Porcelain
;
Denture, Partial, Fixed
;
Head
;
Resin Cements
;
Shoulder
10.A Case of Adenoid Cystic Carcinoma of Bartholin's Gland.
Soon Gyu KIM ; Jin Woo SHIN ; Kwang Il KIM ; Yang Suk KIM ; Jae Seong KANG
Korean Journal of Gynecologic Oncology and Colposcopy 2000;11(2):209-212
Adenoid cystic carcinoma is a rare disease of which incidence is 10-15 % of bartholins gland carcinoma. The clinical presentation is characterized by a vulval mass that existed for a prolonged period to the onset of symptoms, usually infection, pain, and burningsensation Histologically, this tumor is characterized by cribriform pattern cell growing and perineural invasion. The obtaining of clear surgical margins is the most important aspect of treatment. Here we report a case of adenoid cystic carcinoma of the Bartholins gland with a brief review of literature.
Adenoids*
;
Carcinoma, Adenoid Cystic*
;
Incidence
;
Rare Diseases