1.Primary appendiceal adenocarcinoma.
Jae Sub PARK ; Sung Hoon NOH ; Jin Sik MIN
Journal of the Korean Surgical Society 1991;41(4):496-502
No abstract available.
Adenocarcinoma*
2.The effects of acute exercise on plasma concentration of follicular stimulating hormoen(FSH), estradiol, progesterone in women.
Si Young JUNG ; Hee Kyung CHOI ; Young Soo JIN ; Jae Sik SHIM ; Chang Jae LYU
Korean Journal of Obstetrics and Gynecology 1993;36(7):2843-2856
No abstract available.
Estradiol*
;
Female
;
Humans
;
Plasma*
;
Progesterone*
3.Temporary tracheal fenstration in predicting postoperative trachealaspiration.
Bum Jae LEE ; Jae Sik CHO ; Chul Jin YOO ; Chong Won LEE
Korean Journal of Otolaryngology - Head and Neck Surgery 1991;34(2):331-337
No abstract available.
4.In Vitro Tissue Engineering of Cartilage using Autologous Fibrin Glue and Chondrocytes.
Sung Pyo HONG ; Jin Sik BURM ; Jae Kyung PARK ; Jin Young KIM ; Doo Hyung LEE
Journal of the Korean Society of Plastic and Reconstructive Surgeons 1999;26(3):383-391
Neomorphogenesis of cartilage using chondrocyte-polymer constructs is a potential source for development of cartilage reconstruction. Current tissue engineering techniques of neocartilage rely on in vivo implantation of polymer-chondrocyte constructs. The purpose of this study was to find a way to bioengineer cartilage in vitro by entrapping chondrocytes in a molded autologous fibrin glue. Chondrocytes isolated from the cartilage of rabbit joints were combined with fibrinogen extracted by a single cryoprecipitation of autologous plasma, and they were then polymerized with thrombin to create a fibrin glue with a final cell density of 2.5x10(6) cells/ml. The collagen for a control study was used as a polymer. The polymer-chondrocyte constructs were cultured for 4 weeks and the fibrin-chondrocyte constructs molded in the shape of a human ear were cultured for 6 weeks in vitro. Morphometric, histochemical, and histomorphometric analysis including glycosaminoglycan quantitation confirmed the following results: 1) Highly-concentrated autologous fibrinogen was easily extracted by a single cryoprecipition of autologous olasma. 2) The fibrin-chondrocyte constructs demonstrated the presence of actively proliferating chondrocytes with the production of cartilaginous matrix(collagen and glycosaminoglycan) at 1 week after culture, as well as gross and histologic evidence similar to those of normal cartilage at 3-4 weeks after culture. 3) The collagen-chondrocyte constructs demonstrated lower degrees of hardness and transparency, as well as a lower density of cells and glycosaminoglycan during the culture period. 4) Neocartilage generated from fibrin-chondrocyte constructs in the shape of a human ear nearly retained their original configuration and size without degeneration for 6 weeks of culture in vitro. This study demonstrated a novel method for bioengineering the molded cartilage in vitro using autologous fibrin glue as a matrix scaffold. The generated cartilage showed gross and histologic evidence similar to those of normal cartilage, retaining the original gross dimension. With further refinement, this may be a new application of tissue engineering for the reconstruction of cartilage.
Bioengineering
;
Cartilage*
;
Cell Count
;
Chondrocytes*
;
Collagen
;
Ear
;
Fibrin Tissue Adhesive*
;
Fibrin*
;
Fibrinogen
;
Fungi
;
Hardness
;
Humans
;
Joints
;
Plasma
;
Polymers
;
Thrombin
;
Tissue Engineering*
5.Comparison of Conventional Spin Echo, Fast Spin Echo and Fast Multiplanar Spoiled Gradient Recalled Imaging for Evaluation of Focal Hepatic Lesions.
Hyung Sik YOO ; Jae Joon CHUNG ; Myeong Jin KIM ; Jong Tae LEE ; Pil Sik CHOI ; Do Joong KIM
Journal of the Korean Radiological Society 1995;32(3):447-454
PURPOSE: To compare the detectability and conspicuity of focal hepatic lesions among conventional spin echo techniqueniques and fast scanning techniqueniques in MR imaging. MATERIALS AND METHOD: 36 patients (24 men and 12 women, mean age of 54 years) with suspected liver mass on CT scan and US underwent MR imaging at 1.5 T system. Conventional spin echo T1, T2 weighted imaging, T2 weighted fast spin echo, T1 weighted fast multiplanar spoiled gradient recalled(FMPSPGR) imaging and Gd-enhanced FMPSPGR(Gd-FMPSPGR) were performed. 16 cases of hepatocellular carcinoma, 13 cases of hemangioma, 3 cases of metastasis, 3 cases of cholangiocarcinoma, and 1 case of lymphoma were included. Lesion conspicuity and number of detected hepatic masses were compared among the MR sequences. RESULTS: Overall 63 hepatic lesions were detected in 36 patients. Lesion detection' was 63(100%) with Gd-FMPSPGR, 62(98%) with non-enhanced FMPSPGR, 58(92%) with SE T2WI, 56(89%) with SE T1WI and 54 (86%)with FSE. For solid tumors, the contrast to noise ratio was greatest on Gd-FMPSPGR which was significantly higher than any other sequences. For hemangiomas it was greatest on SE T2WI and was significantly higher than SE T1WI. In the qualitative assessment, Gd-FMPSPGR was preferred for both solid mass lesion and hemangioma. FSE was inferior to SE T2WI for lesion detection and conspicuity without statistical significance. CONCLUSIONS: For the evaluation of focal hepatic lesions, breath-hold FMPSPGR with and without contrast enhancement may replace the conventional SE T1WI. Because FSE was inferior to SE T2WI when the later is used with respiratory compensation in some cases, it is difficult to replace the SE T2WI with FSE. But FSE, FMPSPGR and Gd-FMPSPGR images, when combined, may replace SE T1WI and SE T2WI.
Carcinoma, Hepatocellular
;
Cholangiocarcinoma
;
Compensation and Redress
;
Female
;
Hemangioma
;
Humans
;
Liver
;
Lymphoma
;
Magnetic Resonance Imaging
;
Male
;
Neoplasm Metastasis
;
Noise
;
Tomography, X-Ray Computed
6.The Effect of the Valsalva Maneuver on the External Jugular Vein.
Ho Sik MOON ; Sung Hoon JUNG ; Sie Hyeon YOO ; Jae Young JI ; Hae Jin LEE
Korean Journal of Critical Care Medicine 2015;30(3):158-163
BACKGROUND: The external jugular vein (EJV) is a useful intravenous (IV) cannulation site for anesthesiologists, although it has a relatively high failure rate. Unlike other central veins, visualization of the EJV is important during IV cannulation, and the Valsalva maneuver distends the jugular venous system. However, the relationship between the maneuver and EJV visibility remains unknown. This study compared EJV visibility before and after the Valsalva maneuver. METHODS: This was a prospective observational study that included 200 participants. After the induction of anesthesia, EJV visibility grade, depth from the skin to the EJV superficial surface (EJV depth), and EJV cross-sectional area (CSA) before the Valsalva maneuver were measured. The same parameters were measured after the Valsalva maneuver was performed. The EJV visibility grade was defined as grade A: good appearance and good palpation, grade B: poor appearance and good palpation, and grade C: poor appearance and poor palpation. RESULTS: Patient body mass index and EJV depth affected the EJV visibility grade before the Valsalva maneuver (p < 0.05), although EJV CSA did not. The Valsalva maneuver distended EJV CSA and reduced EJV depth, although these changes were not correlated with EJV visibility grade. With regard to EJV visibility, 34.0% of grade B cases and 20.0% of grade C cases were improved by the Valsalva maneuver. CONCLUSIONS: Although the Valsalva maneuver improved EJV CSA and EJV depth, it did not greatly affect EJV visibility grade.
Anesthesia
;
Body Mass Index
;
Catheterization
;
Humans
;
Jugular Veins*
;
Observational Study
;
Palpation
;
Prospective Studies
;
Skin
;
Ultrasonography
;
Valsalva Maneuver*
;
Veins
7.A HISTOMORPHOMETRIC STUDY OF TWO DIFFERENT THREADED CP TITANIUM IMPLANTS.
Dong Hoo HAN ; Young Sik JEON ; Seon Jae KIM ; Jin KIM
The Journal of Korean Academy of Prosthodontics 1999;37(4):531-541
The purpose of this study was to compare surface roughness and bone formation around two types of threaded commercially pure titanium implants manufactured by two different companies. The test implants were manufactured by Sumin synthesis dental materials Co. (Avana, Busan, Korea), while the controls were manufactured by Nobel Biocare (MK II, Goteborg, Sweden). To compare bone formation adjacent to newly product with Branemark MK II implant, surface roughness was measured by Accurate 1500M and histomorphometric analysis was done. The results were as follows : 1. Measurement of surface roughness showed that Avana implant had a slightly more irregular surface compared with Branemark implant. 2. In the light microscopic studies, no infiltration of inflammatory cells nor the giant cells wee observed on both groups. 3. In th light and fluorescent microscopic studies, the amount of osseointegration and the extent and the timing of bone formation were similar. 4. There were no statistically difference between two groups in the average bone to implant contacts. Branemark implant ; 67%(SC 23%), Avana implant ; 70%(SD 16%). Comparing with Branemark implant, Avana implant made of CP grade II titanium showed similar good bone healing, formation and osseointegration.
Busan
;
Dental Materials
;
Giant Cells
;
Osseointegration
;
Osteogenesis
;
Titanium*
8.Use of a Titanium Buttress to Prevent Implant Displacement in Extensive Orbital Blowout Fracture.
Jin Sik BURM ; Jae Hyung HYUAN ; Suk Joon OH ; Tai Suk ROH
Journal of the Korean Society of Plastic and Reconstructive Surgeons 2000;27(1):92-96
The operative treatment of orbital blowout fracture involves restoration of intra-orbital soft tissue and bony structural integrity. In extensive blowout fracture, postoperative edema and subsequent increase of intraoribital pressure may sometimes lead to displace the implant. To prevent postperative displacement of the implant, we tried reinforcing the implant using a buttress consisting of micro-titanium mesh and titanium mesh in 13 cases of extensive orbital blowout fracture, including medical wall fracture (6), inferior wall fracture (5) and inferomedial wall fracture (2). A small thin titanium buttress was inserted beneath the implant at the point where intraorbital pressure was involved maximally. It was usually placed superoinferiorly in a medial wall fracture wall fracture, mediplaterally along th posterior ridge of bony defect in an inferior wall fracture, and anteroposteriorly in an inferomedial wall fracture. No evidence of implant displacement after operation was noted in any cases and this was confirmed by postoperative computed tomographic scan. Also, any complication by a titanium buttress did not occur. Orbital implant reinforcement using a titanium buttress may be an available technique for preventing implant displacement in reconstruction of extensive orbital blowout frature.
Edema
;
Orbit*
;
Orbital Implants
;
Titanium*
9.The treatment of a frequently water intoxicated chronic schizophrenia case.
Young Sik LEE ; Jin Tae CHOI ; Jae Kwang LEE ; Kil Hong LEE
Journal of Korean Neuropsychiatric Association 1992;31(6):1123-1130
No abstract available.
Schizophrenia*
;
Water*
10.The treatment of a frequently water intoxicated chronic schizophrenia case.
Young Sik LEE ; Jin Tae CHOI ; Jae Kwang LEE ; Kil Hong LEE
Journal of Korean Neuropsychiatric Association 1992;31(6):1123-1130
No abstract available.
Schizophrenia*
;
Water*