1.Correlation of anxiety and depression with coping strategy in hemodialysis patients.
Jae Hyung RYU ; Hyung Yung LEE
Journal of Korean Neuropsychiatric Association 1992;31(3):587-594
No abstract available.
Anxiety*
;
Depression*
;
Humans
;
Renal Dialysis*
2.A comparative study on the cognitive dysfunction between paranoid and nonparanoid schizophrenics.
Young Jae SEOL ; Hyung Yung LEE
Journal of Korean Neuropsychiatric Association 1991;30(1):88-97
No abstract available.
3.Identification of the Orchid Mycorrhizal Fungi Isolated from the Roots of Korean Native Orchid.
Mycobiology 2000;28(1):17-26
The orchid symbiotic fungi were isolated from the roots of Korean native orchid (Cymbidium goeringii) collected and Chinese orchid (C. sinense) obtained from greenhouses. They were identified as a species of Rhizoctonia, based on the sequences of 18r rDNA, the microscopic observations of mycelia, and the symbiotic relationships with commercial orchids. The isolate collected from Chinese orchids was revealed to be a species of Ceratobasidium endophytica, and to be different from the other isolates at the thickness of the mycelia stained in the root cells of Korean native orchids. The other isolates collected from the Korean native orchids were considered to be a species of Tulsanella repens (anamorphic: Epulorhiza repens) or its related one. The physiologic or microscopic variations were oftenly observed among them, but the tendency of grouping these in the 18s rDNA sequences were observed to be consistent with those of the localities collected. The further taxonomical segregating for Korean symbiotic fungi was not made because the information concerned were limited in this moment, but was recognized as based on the sequences of 18s DNA.
Asian Continental Ancestry Group
;
DNA
;
DNA, Ribosomal
;
Fungi*
;
Humans
;
Mycorrhizae
;
Rhizoctonia
;
Symbiosis
4.A study on the effect of rotational speeds of the trephine mill on the temperature of surrounding bone during dental implantation procedure and osseointegration of implants.
Jin Geol LEE ; Jae Ho YANG ; Sun Hyung LEE
The Journal of Korean Academy of Prosthodontics 1992;30(2):167-189
No abstract available.
Dental Implantation*
;
Dental Implants*
;
Osseointegration*
5.A Case of Multicystic Renal Dysplasia with Chromosomal Abnormality.
Myung Jae LEE ; Soon In JUNG ; Jae Hyung NA ; Jae Hong KIM ; Jong Jae JUNG
Korean Journal of Perinatology 1999;10(1):56-60
Holoprosencephaly is a rare and complex malformation affecting the cleavage of the developing forebrain and is usually associated with defects of the mid Face. We have experienced a case of holoprosencephaly, diagnosed prenatally by ultrasound examination at 31 weeks of pregnancy in a 31-year-old primigravida woman. This case is characterized by holoprosencephaly, cleft palate, cleft lip, left renal aplasia and right renal hypertrophy. The chromosomal study showed a deletion of the long arm of chromosome 7, 46, XX, del(7)(q32), We report with a terminal deletion of chromosome 7q associated with atypical clinical picture and holoprosencephaly.
Adult
;
Arm
;
Chromosome Aberrations*
;
Chromosomes, Human, Pair 7
;
Cleft Lip
;
Cleft Palate
;
Female
;
Holoprosencephaly
;
Humans
;
Hypertrophy
;
Multicystic Dysplastic Kidney*
;
Pregnancy
;
Prosencephalon
;
Ultrasonography
6.Expression of Prostatic Carcinoma Oncogene PTI - 1 in Prostatic Carcinoma , Prostatic Intraepithelial Neoplasia and Benign Prostatic Hyperplasia Using in situ PCR .
Tae Jin LEE ; Eon Sub PARK ; Jae Hyung YOO
Journal of the Korean Cancer Association 2000;32(1):136-147
PURPOSE: Prostatic tumor induced gene-1 (PTI-1) is a mutated human EF-la and putative prostatic carcinoma tumor-inducing oncogene, that is differently expressed in prostatic cancer and benign prostatic hyperplasia. And, it is more sensitive marker than prostate- specific antigen (PSA) for detecting human prostate cancer in the bloodstream. This study invastigated the expression of PTI-1 in paraffin embedded tissue of prostatic carcinoma, prostatic intraepithelial neoplasia, and benign prostatic hyperplasia using in situ PCR. MATERIALS AND METHODS: we evaluated expression of PTI-1 in prostatic carcinoma with prostatic intraepithelial neoplasia (PIN) of 32 cases, benign hyperplasia of 20 cases, high grade transitional cell carcinoma of 10 cases and colon cancer of 10 cases for control group. Also, the immunohistochemical staining for PSA was performed to comparison with clinical value of PSA. RESULTS: The serum level of PSA was closely related to stage and Gleason score (p < 0.05). However, the results of immunohistochemical stains were variable to stage and Gleason score. PTI-1 using in situ PCR expressed in 50% of prostatic carcinoma, 41% of prostatic intraepithelial neoplasia, 10% of benign hyperplasia and colon cancer (p < 0.05). No expression is observed in transitional cell carcinoma. In prostatic carcinoma, PTI-1 expressed in 43.8% (7/16) of stage II, 50.0% (5/10) of stage III, and 66.7% (4/6) of stage IV (p<0.05). In PIN, expression of PTI-1 was similar to prostatic carcinoma (p<0.05). CONCLUSION: PTI-1 represented a relatively sensitive marker for prostatic carcinoma and PIN, indicator of prostatic carcinoma progression.
Carcinoma, Transitional Cell
;
Colonic Neoplasms
;
Coloring Agents
;
Humans
;
Hyperplasia
;
Neoplasm Grading
;
Oncogenes*
;
Paraffin
;
Polymerase Chain Reaction*
;
Prostatic Hyperplasia*
;
Prostatic Intraepithelial Neoplasia*
;
Prostatic Neoplasms
7.A study on the effects of early loading on the surrounding bone tissue of the dental implants.
Hui Un PARK ; Jae Ho YANG ; Sun Hyung LEE
The Journal of Korean Academy of Prosthodontics 1993;31(1):101-127
No abstract available.
Bone and Bones*
;
Dental Implants*
8.Influence of Thickness of Empress 2 Ceramic on Fracture Strength.
Jung Woo KOH ; Jae Ho YANG ; Sun Hyung LEE
The Journal of Korean Academy of Prosthodontics 2000;38(4):446-460
All ceramic restorations have had a more limited life expectancy than metal ceramic crowns because of their lower strength. The relatively lower strength has limited the use of all-ceramic crowns to the areas where occlusal loads are lower. Therefore many researches have been done to increase the strength of all-ceramic crowns. IPS Empress 2 is a new type of lithium disilicate glass-ceramic with enhanced physical characteristics which has been in use clinically since 1998. Previous researches reported that the flexural strength of all-ceramic material was greater than 300MPa, and all-ceramic crowns can be used in staining or layering technique. The objective of this study was to investigate the influence of the thickness of IPS Empress 2 ceramic on fracture strength. Both staining technique and layering technique was investigated. Vita VMK was used as control. For all three groups, five specimens each of 0.8mm, 1.0mm, 1.4mm, 1.8mm, and 2.2mm thickness (a total of 75 specimens) were prepared. Control group: Vita VMK Porcelain specimens were prepared with dentine ceramic and liquid glazing was done. Group I: IPS Empress 2 were prepared with staining technique and stained twice and glazed once. Group II : IPS Empress 2 were prepared with layering technique and glazed after wash firing. The thickness and diameter of the specimen were measured and controlled after specimen preparation. Biaxial Flexure Test (ASTM Standard F394-78) was adopted as this test method produces results least affected by the edge condition of the specimens. Fracture strength was measured with Instron Universal Testing Machine. Conclusions are as follow : 1. The fracture strength was increase in order of control group, test group I, test group II. 2. Fracture strength of the group I(Empress 2 Staining) was 65.54 N in 0.8mm, 155.2 N in 1.0mm, 233.5 N in 1.44mm, 434.5 N in 1.8mm, and 600.1 N in 2.2mm. 3. Fracture strength of the group II (Empress 2 Layering) was 190.0 N in 0.8mm, 283.5 N in 1.0mm, 437.2 N in 1.4mm, 732.0 N in 1.8mm, and 1115.0 N in 2.2mm. 4. No statistical difference was found in flexural strengths according to thickness in a specified group(p>0.05).
Ceramics*
;
Crowns
;
Dental Porcelain
;
Dentin
;
Fires
;
Life Expectancy
;
Lithium
9.An In-Vitro Wear Study of Ceromer and Human Enamel.
Jeong Min KIM ; Sun Hyung LEE ; Jae Ho YANG
The Journal of Korean Academy of Prosthodontics 2000;38(4):438-445
The ideal restorative material should mimic the properties of the tissues it replaces. Dental composite resins have been used widely as restorative materials due to its advantages such as excellent esthetics and ease of manipulation. But inadequate wear resistance has been a major factor limiting the use of composite restorative materials. Improved manufacturing techniques have allowed the development of hybrid composites, with a greater percentage volume filler loading, which have improved physical an mechanical properties. However they are lacking the study wear resistance. The purpose of this study was to evaluate the wear of human enamel against ceromer by the use of a pin-on-disk type wear testers. Discs of ceromer(Targis : Ivoclar, Vivadent, Amherst. NY) and discs of type III gold alloy as a control were used for test specimens. Intact cusp of premolar and molar were used for enamel specimens. The wear of enamel was determined by weighing the cusp before and after each test, and the weight converted to volumes by average density of enamel. Surface profilometer was used to quantify wear of the ceromer and gold specimens. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows; 1. Ceromer produced less enamel wear than gold(p<0.05). 2. The wear volume of ceromer was greater than that of gold(p<0.01). 3. The hardess of ceromer was lower than that of gold, but there was no correlation between the hardness and wear of the ceromer and gold. 4. SEM analysis revealed that there were many voids and microcracks in the wear tract of ceromer. in gold group, many minute V-shaped grooves were examined.
Alloys
;
Bicuspid
;
Composite Resins
;
Dental Enamel*
;
Esthetics
;
Hardness
;
Hardness Tests
;
Humans*
;
Molar
10.A study of artifacts in MR imaging induced by metalic aneurysm clips.
Joo Hyuk LEE ; Kee Hyun CHANG ; Jae Hyung PARK
Journal of the Korean Radiological Society 1992;28(2):307-313
To investigate MR artifacts induced by metallic implants, scans were obtained using both the ferromagnetic Drake lip and the non ferromagnetic Yasargil clip. Scan were taken through the area of clips using geometrical phantom. The MRI was performed by spin echo technique and gradient echo technique on both 2.0T and 0.5T MR unit. The luthors evaluated the nature and differences of artifacts in each sequence and parameter. Artifacts induced by both lips were noted in the direction of frequency encoding gradient, and consisted of region of signal loss abutted in one side by survilinear region of bright signal. Geometric distortion of image was marked in the Drake clip, out was minimal in the Yasargil clip under both 2.0T and 0.5T. Artifacts were more pronounced in the gradient echo technique than those of the spin echo technique on both 2.0T and 0.5T. Although there were no differences n the nature of artifacts induced by the Drake clip among each parameter in the spin echo technique under 2.0T, artifacts were slightly more pronounced on T2 weighted image under the 0.5T field, but no differences were found in the nature of artifacts induced by the Yasargil clip in the spin echo technique under, both the 2.0T and 0.5T fields. Marked artifacts were induced through the small area of the Drake clip which were included in the scan plane, but induced artifacts were small when a small area of the Yasargil clip was included in the scan plane. It seemed likely hat artifacts were slightly more pronounced in the 2.0T than the 0.5T field in both clips, but objective evaluation of the difference was difficult, In conclusion, these results can be an essential basis for the interpretation of MR images or patents with metallic inplants.
Aneurysm*
;
Artifacts*
;
Lip
;
Magnetic Resonance Imaging*
;
Magnets