1.Ipsilateral Fractures of the Hip and Femoral Shaft
The Journal of the Korean Orthopaedic Association 1988;23(3):713-721
Thirteen cases of concomitant hip and shaft fractures of the same femur are reported. The hip fractures was initially missed in one case. Osteosynthesis of both fractures was performed in twelve cases. One except was 12-year-old boy who was managed hip with two Knowles pins and shaft conservatively. Both fractures healed in all followed for average 5.3 months or more. Osteosynthesis of both fractures is recommended as soon as the patient is in a stable condition, preferably by early fixation with AO principle or IM nailing in selected cases.
Child
;
Femur
;
Hip Fractures
;
Hip
;
Humans
;
Male
2.Abdominoplasty.
Yeungnam University Journal of Medicine 1993;10(2):287-297
No abstract available.
Abdominoplasty*
3.The treatment of congenital cutis aplasia.
Young Ha KIM ; Gyu Ho CHA ; Jae Ho JUNG ; Kyung Ho LEE ; Jung Hyun SEUL
Yeungnam University Journal of Medicine 1992;9(2):422-426
One case of congenital cutis aplasia is presented. The defect involved includes full-thickness skin defect of scalp and cranium. The patient was treated with debridement of dirty necrosed crust which covered exposed dura mater and with double opposing rotation flap including pericranium for bone regeneration. The donor site was covered with skin graft from right thigh. During operation, the superficial temporal artery was found to be short and weak. And after operation, the margin of flap were congested and finally necrotized. The necrotic wound was treated with conservative management. The vascular impairment is thought to be main course of congenital cutis aplasia. So we conclude that the treatment of choice is conservative management or careful flap surgery for coverage of defect area.
Bone Regeneration
;
Debridement
;
Dura Mater
;
Estrogens, Conjugated (USP)
;
Humans
;
Scalp
;
Skin
;
Skull
;
Temporal Arteries
;
Thigh
;
Tissue Donors
;
Transplants
;
Wounds and Injuries
4.Continuous Sutures for Microarterial Anastomosis.
Yung Sik JUNG ; See Ho CHOI ; Jae Ho CHUNG ; Jung Hyun SEUL
Yeungnam University Journal of Medicine 1986;3(1):237-241
In clinical microsurgery, limitation of space often prohibits rotation of a double clamp in an end-to-end anastomosis, or shortage of length of the secondary vessel in an end-to-side anastomosis does not allow visualization of the back wall. In these situation, back wall repair is extremely difficult. To overcome this problem, we use continuous suture technique without rotation of double clamp for end-to-end and end-to-side anastomosis of the 40 rat femoral arteries. After continuous sutures for micro-arterial anastomosis, the following results were obtained: Continuous sutures are useful in anastomosis where there is unavoidable limited access to the posterior wall and for some of the larger vessels now being anastomosed in free flap and other reconstructive surgery.
Animals
;
Femoral Artery
;
Free Tissue Flaps
;
Microsurgery
;
Rats
;
Suture Techniques
;
Sutures*
5.NO2- and ATP synthesis in the EMT-6 cell stimulated by mercury chloride.
Gyung Jae OH ; Dai Ha KOH ; Jung Ho YOUM
Korean Journal of Preventive Medicine 1996;29(3):495-506
Effect of Mercury chloride on the synthesis of NO2- and ATP were observed in EMT-6 cells which were culture with cytokines(IL-1alpha and IFN-gamma) and various concentrations of mercury chloride from 0.05 to 0.08 M. Viability of EMT-6 cells were observed above 90% in almost groups. There were not significant differences in the viability between mercury supplemented groups and control group. It suggests viability of EMT-6 cells were not influenced by these concentrations of mercury chloride. Results of the synthesis of nitrite showed significant time and group effect. There is a significant interaction effect between concentration of mercury chloride and culture time. The effect of various concentration of mercury chloride is not the same for all levels of culture time. There were significant differences in the synthesis of nitrite between mercury chloride supplemented groups and control group, and the synthesis of nitrite in EMT-6 cell by the supplement of mercury chloride was significantly decreased in a dose-dependent manner. Results of the synthesis of ATP showed a significant group effect, and the time main effect and the Group x Time interaction were also significant. There were significant differences in the synthesis of ATP between mercury chloride supplemented groups and control group, and the synthesis of ATP in EMT-6 cell by the supplement of mercury chloride was significantly decreased in a dose-dependent manner. These results suggest that the disorder of cell mediated immunity by mercury chloride could be related to the inhibition of nitric oxide synthesis which will be caused by the decreased synthesis of ATP.
Adenosine Triphosphate*
;
Immunity, Cellular
;
Nitric Oxide
7.FRACTURE STRENGTH AND MARGINAL FIT OF IN-CERAM, COPY-MILLED IN-CERAM, AND IPS EMPRESS 2 ALL-CERAMIC BRIDGES.
Jung Won HWANG ; Jae Ho YANG ; Sun Hyung LEE
The Journal of Korean Academy of Prosthodontics 2001;39(6):641-658
All-ceramic restorations have become an attractive alternative to porcelain-fused-to-metal crowns. In-Ceram, and more recently IPS Empress 2 were introduced as a new all-ceramic system for single crowns and 3-unit fixed partial dentures. But their strength and marginal fit are still an important issue. This study evaluated the fracture resistance and marginal fit of three systems of 3 unit all-ceramic bridge fabricated on prepared maxillary anterior resin teeth in vitro. The 3 all-ceramic bridge systems were: (1) a glass-infiltrated, sintered alumina system (In-Ceram) fabricated conventionally, (2) the same system with copy-milled alumina cores (copy-milled In-Ceram), (3) a heat pressed, lithium disilicate reinforced glass-ceramic system (IPS Empress 2). Ten bridges of each system with standardized design of framework were fabricated. All specimens of each system were compressed at 55degree at the palatal surface of pontic until catastrophic fracture occurred. Another seven bridges of each system were fabricated with standard method. All of the bridge-die complexes were embedded in epoxy resin and sectioned buccolingually and mesiodistally. The absolute marginal discrepancy was measured with stereomicroscope at x50 power. The following results were obtained: 1. There was no significant difference in the fracture strength among the 3 systems studied. 2. The Weibull modulus of copy-milled In-Ceram was higher than that of In-Ceram and IPS Empress 2 bridges. 3. Copy-milled In-Ceram (112micrometer) exhibited significantly greater marginal discrepancy than In-Ceram (97micrometer), and IPS Empress 2 (94micrometer at P=0.05. 4. The lingual surfaces of the ceramic crowns showed smaller marginal discrepancies than mesial and distal points. There was no significant difference between teeth (incisor, canine) at P=0.05. 5. All-ceramic bridges of three systems appeared to exhibit sufficient initial strength and acceptable marginal fit values to allow clinical application.
Aluminum Oxide
;
Ceramics
;
Crowns
;
Denture, Partial, Fixed
;
Hot Temperature
;
Lithium
;
Tooth
8.Hepatic tuberculous granuloma with subphrenic abscess: a case report .
Sang Cho JUNG ; Jae Ho AHN ; Sung Tae OH
The Korean Journal of Thoracic and Cardiovascular Surgery 1991;24(6):585-589
No abstract available.
Granuloma*
;
Subphrenic Abscess*
9.Influence of Thickness of Empress 2 Ceramic on Fracture Strength.
Jung Woo KOH ; Jae Ho YANG ; Sun Hyung LEE
The Journal of Korean Academy of Prosthodontics 2000;38(4):446-460
All ceramic restorations have had a more limited life expectancy than metal ceramic crowns because of their lower strength. The relatively lower strength has limited the use of all-ceramic crowns to the areas where occlusal loads are lower. Therefore many researches have been done to increase the strength of all-ceramic crowns. IPS Empress 2 is a new type of lithium disilicate glass-ceramic with enhanced physical characteristics which has been in use clinically since 1998. Previous researches reported that the flexural strength of all-ceramic material was greater than 300MPa, and all-ceramic crowns can be used in staining or layering technique. The objective of this study was to investigate the influence of the thickness of IPS Empress 2 ceramic on fracture strength. Both staining technique and layering technique was investigated. Vita VMK was used as control. For all three groups, five specimens each of 0.8mm, 1.0mm, 1.4mm, 1.8mm, and 2.2mm thickness (a total of 75 specimens) were prepared. Control group: Vita VMK Porcelain specimens were prepared with dentine ceramic and liquid glazing was done. Group I: IPS Empress 2 were prepared with staining technique and stained twice and glazed once. Group II : IPS Empress 2 were prepared with layering technique and glazed after wash firing. The thickness and diameter of the specimen were measured and controlled after specimen preparation. Biaxial Flexure Test (ASTM Standard F394-78) was adopted as this test method produces results least affected by the edge condition of the specimens. Fracture strength was measured with Instron Universal Testing Machine. Conclusions are as follow : 1. The fracture strength was increase in order of control group, test group I, test group II. 2. Fracture strength of the group I(Empress 2 Staining) was 65.54 N in 0.8mm, 155.2 N in 1.0mm, 233.5 N in 1.44mm, 434.5 N in 1.8mm, and 600.1 N in 2.2mm. 3. Fracture strength of the group II (Empress 2 Layering) was 190.0 N in 0.8mm, 283.5 N in 1.0mm, 437.2 N in 1.4mm, 732.0 N in 1.8mm, and 1115.0 N in 2.2mm. 4. No statistical difference was found in flexural strengths according to thickness in a specified group(p>0.05).
Ceramics*
;
Crowns
;
Dental Porcelain
;
Dentin
;
Fires
;
Life Expectancy
;
Lithium
10.A clinical study of peptic ulcer perforation.
Ki Jae CHO ; In Ho JUNG ; Kun Pil CHOI
Journal of the Korean Surgical Society 1991;40(6):737-746
No abstract available.
Peptic Ulcer Perforation*
;
Peptic Ulcer*