1.Percutaneous transhepatic cholangiography.
; H C HUNG ; T S CHU ; P J T'ANG
Chinese Journal of Surgery 1963;11():282-284
2.Aligning the Good Practice MASK With the Objectives of the European Innovation Partnership on Active and Healthy Ageing
J BOUSQUET ; J FARRELL ; M ILLARIO ;
Allergy, Asthma & Immunology Research 2020;12(2):238-258
The reference sites of the European Innovation Partnership on Active and Healthy Ageing (EIP on AHA) were renewed in 2019. The DG Santé good practice Mobile Airways Sentinel networK was reviewed to meet the objectives of the EIP on AHA. It included 1) Management of care process, 2) Blueprint of digital transformation, 3) EIP on AHA, innovation to market, 4) Community for monitoring and assessment framework, 5) Political, organizational, technological and financial readiness, 6) Contributing to European co-operation and transferability, 7) Delivering evidence of impact against the triple win approach, 8) Contribution to the European Digital Transformation of Health and Care and 9) scale of demonstration and deployment of innovation
Asthma
;
Masks
;
Mobile Applications
;
Rhinitis
3.Novel Coronaviruses and Astroviruses in Bats
Daniel K. W. Chu ; J. S. Malik Peiris ; Leo L. M. Poon
Virologica Sinica 2009;24(2):100-104
Zoonotic transmissions of emerging pathogens from wildlife to human have shaped the history of mankind. These events have also highlighted our poor understanding of microorganisms circulated in wild animals. Coronaviruses and astroviruses, which can be found from a wide range of mammals, were recently detected in bats. Strikingly, these bat viruses are genetically highly diverse and these interesting findings might help to better understand the evolution and ecology of these viruses. The discoveries of these novel bats viruses not only suggested that bats are important hosts for these virus families, but also reiterated the role of bats as a reservoir of viruses that might pose a zoonotic threat to human health.
4.Design and Dose Distribution of Docking Applicator for an Intraoperative Radiation Thherapy.
Sung Sil CHU ; Gwi Eon KIM ; John J L LOH
Journal of the Korean Society for Therapeutic Radiology 1991;9(1):123-130
A docking intraoperative electron beam applicator system, which is easily docking in the collimator for a linear accelerator after setting a sterilized transparent cone on the tumor bearing area in the operation room, has been designed to optimize dose distribution and to improve the efficiency of radiation treatment method with linear accelerator. This applicator system consisted of collimator holder with shielded metals and docking cone with transparent acrylic cylinder. A number of technical innovations have been used in the design of this system, this docking cone gives a improving latral dose coverage at therapeutic volume. The position of 90% isodose curve under surface of 8 cm diameter cone was extended 4~7 mm at 12 MeV electron and the isodose measurements beneath the cone wall showed hot spots as great as 106% for acrylic cone. The leakage radiation dose to tissues outside the cone wall was reduced as 3~5% of output dose. A comprehensive set of dosimetric characteristics of the intraoperative radiation therapy applicator system is presented.
Metals
;
Particle Accelerators
5.Dosimetry for Total Skin Electron Beam Therapy in Skin Cancer.
Sung Sil CHU ; John J K LOH ; Gwi Eon KIM
Journal of the Korean Society for Therapeutic Radiology 1992;10(1):107-114
Increasing frequency of skin cancer, mycosis fungoides, Kaposi's sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a 0.5cm x90cm x180cm acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. During treatment, the patient was placed in six different positions due to be homogeneous dose distribution for whole skin around the body. One treatment session delivered 400 cGy to the entire skin surface and patients were treated twice a week for eight consecutive weeks, which is equivalent to TDF value 57. Instrumentation and techniques developed in determining the depth dose, dose distribution and bremsstrahlung dose are discussed.
Foot
;
Head
;
Humans
;
Mycosis Fungoides
;
Particle Accelerators
;
Sarcoma, Kaposi
;
Skin Neoplasms*
;
Skin*
;
Toes
6.Cooperative clinical studies of hyperthermia using a capacitive type heating device GHT-RF8(Greenytherm).
John J K LOH ; Jin Sil SEONG ; Chang Ok SUH ; Gwi Eon KIM ; Sung Sil CHU ; Kyung Ran PAK ; Chang Geol LEE ; Byung Soo KIM ; Soo Gon KIM ; David J SEEL
Yonsei Medical Journal 1989;30(1):72-80
Yonsei Cancer Center developed an RF(Radiofrequency) capacitive type heating device, GHT-RF8(Greenytherm) in cooperation with Green Cross Medical Corp., Korea in 1986 for the first time in Korea. Cooperative clinical studies of hyperthermia for the treatment of cancer using GHT-RF8 were conducted by Yonsei Cancer Center in collaboration with the Presbyterian Medical Center, Chonju, Korea. A total of forty patients with various histologically proven malignant tumors, including superficial (N = 13) and deep-seated tumors (N = 27), were treated with this newly developed heating device in conjunction with radiotherapy (N = 38) or chemotherapy (N = 2) at two different institutes between October 1986 and September 1987. These patients were locally far advanced or recurrent cases and considered to be refractory to conventional cancer treatment modalities. Radiotherapy was given in 200cGy per day, five times a week fractionations with a total tumor dose of 50-60Gy in 5-6 weeks. Within an hour after radiotherapy, the RF capacitive type of hyperthermia was given two times a week for a total of 4-10 treatment sessions and an attempt was made to maintain the tumor temperature at 41-45 degrees C for 30-60 minutes. Of forty patients treated, 14 patients with deep-seated tumors showed complete response and 20 patients showed partial response. The overall response rate was 85% (34 out of 40 patients) and only 6 patients showed no response. Complications from this treatment were mainly burns, superficial first degree burn in 2 cases, second degree in 4 cases and subcutaneous fat necrosis was observed in 2 cases.
Adolescent
;
Adult
;
Aged
;
Equipment Design
;
Female
;
Heating/*instrumentation
;
Human
;
Hyperthermia, Induced/adverse effects/*instrumentation
;
Male
;
Middle Age
;
Neoplasms/radionuclide imaging/therapy
;
Support, Non-U.S. Gov't
;
Tomography, X-Ray Computed
8.Treatment Planning and Dosimetry of Small Radiation Fields for Stereotactic Radiosurgery.
Sung Sil CHU ; Chang Ok SUH ; John J K LOH ; Sang Sup CHUNG
Journal of the Korean Society for Therapeutic Radiology 1989;7(1):101-112
The treatment planning and dosimetry of small fields for stereotactic radiosurgery with 10 MV x-ray isocentrically mounted linear accelerator is presented. Special consideration in this study was given to the variation of absorbed dose with field size, the central axis percent depth doses and the combined moving beam dose distributon. The collimator scatter correction factors of small fields (1x1~3x3 cm2) were measured with ion chamber at a target chamber distance of 300cm where the projected fields were larger than the polystyrene buildup caps and it was calibrated with the tissue equivalent solid state detectors of small size (TLD, PLD, ESR and semiconductors). The central axis percent depth doses for 1x1 and 3x3 cm2 fields could be derived with the same acuracy by interpolating between measured values for larger fields and calcu1ated zero area data, and it was also calibrated with semiconductor detectors. The agreement between experimental and calculated data was found to be under +/-2% within the fields. The three dimensional dose planning of stereotactic focusing irradiation on small size tumor regions was performed with dose planning computer system (Therac 2300) and was verified with film dosimetry. The more the number of strips and the wider the angle of arc rotation, the larger were the dose delivered on tumor and the less the dose to surrounding the normal tissues. The circular cone, we designed, improves the alignment, minimizes the penumbra of the beam and formats ball shape of treatment area without stellate patterns. These dosimetric techniques can provide adequate physics background for stereotactic radiosurgery with small radiation fields and 10 MV x-ray beam.
Axis, Cervical Vertebra
;
Computer Systems
;
Film Dosimetry
;
Particle Accelerators
;
Polystyrenes
;
Radiosurgery*
;
Semiconductors
9.Unusual Angular Arrangement of Electrodes in Capacitive Heating Device: Thermal Distribution and Clinical Application.
Jin Sil SEONG ; Sung Sik CHU ; Gwi Eon KIM ; Sung Wha YANG ; John J Kyu LOH
Journal of the Korean Society for Therapeutic Radiology 1989;7(2):313-320
In capacitive heating device, which considered efficient for deep heating, parallel arrangement of the electrodes is a serious limiting factor in heating for eccentrically located lesions because it causes overheating of the exposed ipsilateral skin surface, the heating pattern is also frequently inappropriate, arid the arrangement tends to be unstable due to the patient's gravity. Therefore we attempted an angular arrangement of the electordes to achieve more homogenous and efficient heating for such lesions. In phantom study, both the thermal profile and thermogram established the heating pattern in this unusual angular arrangement of the electrodes at 60degree, 90degree and 120degree angles, respectively. An angular arrangement was also clinically applied to 3 patients. The patients' tolerance was good without significant complication and the thermal distribution was satisfactory. In conclusion, this unusual arrangement of electrodes appears to be promising in the clinical application to the eccentrically located lesions.
Electrodes*
;
Gravitation
;
Heating*
;
Hot Temperature*
;
Humans
;
Skin
10.Interferon beta-1b is effective and has a favourable safety profile in Chinese patients with relapsing forms of multiple sclerosis
ZX Li ; CZ Lu ; XH Zhang ; LY Cui ; XH Xu ; E Radue ; SG Chu ; LR Wang ; K Beckmann ; J Lampe ; C Pohl ; B Stemper ; R Sandbrink
Neurology Asia 2014;19(2):179-189
Background & Objective: No clinical study of any interferon beta therapy has yet been successfully conducted in Chinese multiple sclerosis patients, probably due to the low incidence of this disease in China. The primary objective of this study was to demonstrate that treating multiple sclerosis patients of Chinese origin with interferon beta-1b has a beneficial effect on disease course, as measured by the decrease of newly active lesions on magnetic resonance imaging. Methods: Chinese patients diagnosed with relapsing-remitting or secondary-progressive multiple sclerosis were enrolled in this multicenter, open label, single-arm study. Following a 3-month pre-treatment phase, patients were treated with 250 µg interferon beta-1b subcutaneously every other day for 6 months. Patients had regular assessments for treatment safety and efficacy of the treatment. Results: Thirty seven patients completed the trial. Significant decreases in the number of newly active lesions were observed in the 6-month treatment period compared with the pre-treatment period (median decrease 1.5 lesions, p<0.001). Most adverse events were mild and transient and no serious ones were observed. Conclusions: Treatment with interferon beta-1b significantly reduced the occurrence of new lesions and was well tolerated in this Chinese population. These findings support the use of interferon beta- 1b for treating Chinese MS patients.