1.Cone-beam computed tomography artifacts in the presence of dental implants and associated factors: An integrative review
Bianca Rodrigues TERRABUIO ; Caroline Gomes CARVALHO ; Mariela PERALTA-MAMANI ; Paulo Sérgio da SILVA SANTOS ; Izabel Regina Fischer RUBIRA-BULLEN ; Cássia Maria FISCHER RUBIRA
Imaging Science in Dentistry 2021;51(2):93-106
Purpose:
This study was conducted to review the literature regarding the types of cone-beam computed tomography (CBCT) artifacts around dental implants and the factors that influence their formation.
Materials and Methods:
A search strategy was carried out in the PubMed, Embase, and Scopus databases to identify published between 2010 and 2020, and 9 studies were selected. The implants included 306 titanium, titanium-zirconium, and zirconia implants, as well as 5 titanium cylinders.
Results:
The artifacts around the implants were the beam-hardening artifact, the streaking artifact, and band-like radiolucent areas. Some factors that influenced the formation of artifacts were the implant material, bone type, evaluated regions, distance, type of CBCT, field of view (FOV) size, milliamperage, peak kilovoltage (kVp), and voxel size. The beam-hardening artifact was the most widely reported, and it was minimized in protocols with a smaller FOV, larger voxels, and higher kVp.
Conclusion
The risk and benefit of these protocols in individuals with dental implants must be considered, and clinical examinations and complementary radiographs play an essential role in implantology.
2.Comparison of limited- and large-volume cone-beam computed tomography using a small voxel size for detecting isthmuses in mandibular molars
Elen de Souza TOLENTINO ; Pablo Andrés AMOROSO-SILVA ; Murilo Priori ALCALDE ; Fernanda Chiguti YAMASHITA ; Lilian Cristina VESSONI IWAKI ; Izabel Regina Fischer RUBIRA-BULLEN ; Marco Antônio HÚNGARO DUARTE
Imaging Science in Dentistry 2021;51(1):27-34
Purpose:
This study was performed to compare the ability of limited- and large-volume cone-beam computed tomography (CBCT) to display isthmuses in the apical root canals of mandibular molars.
Materials and Methods:
Forty human mandibular first molars with isthmuses in the apical 3 mm of mesial roots were scanned by micro-computed tomography (micro-CT), and their thickness, area, and length were recorded. The samples were examined using 2 CBCT systems, using the smallest voxels and field of view available for each device. The Mann-Whitney, Friedman, and Dunn multiple comparison tests were performed (α=0.05).
Results:
The 3D Accuitomo 170 and i-Cat devices detected 77.5% and 75.0% of isthmuses, respectively (P>0.05). For length measurements, there were significant differences between micro-CT and both 3D Accuitomo 170 and i-Cat (P<0.05).
Conclusion
Both CBCT systems performed similarly and did not detect isthmuses in the apical third in some cases. CBCT still does not equal the performance of micro-CT in isthmus detection, but it is nonetheless a valuable tool in endodontic practice.