1.Usefulness of the S-O clip for duodenal endoscopic submucosal dissection: a propensity score-matched study
Ippei TANAKA ; Dai HIRASAWA ; Hiroaki SAITO ; Junichi AKAHIRA ; Tomoki MATSUDA
Clinical Endoscopy 2023;56(6):769-777
Background/Aims:
Endoscopic submucosal dissection (ESD) for superficial non-ampullary duodenal tumors (SNADETs) is associated with a high rate of en bloc resection. However, the technique for ESD remains challenging. Recent studies have demonstrated the effectiveness of S-O clips in colonic and gastric ESD. We evaluated the efficacy and safety of duodenal ESD using an S-O clip for SNADETs.
Methods:
Consecutive patients who underwent ESD for SNADETs between January 2011 and December 2021 were retrospectively enrolled. Propensity score matching analysis was used to compare patients who underwent duodenal ESD with the S-O clip (S-O group) and those who underwent conventional ESD (control group). Intraoperative perforation rate was the primary outcome, while procedure time and R0 resection rate were the secondary outcomes.
Results:
After propensity score matching, 16 pairs were created: 43 and 17 in the S-O and control groups, respectively. The intraoperative perforation rate in the S-O group was significantly lower than that in the control group (p=0.033). A significant difference was observed in the procedure time between the S-O and control groups (39±9 vs. 82±30 minutes, respectively; p=0.003).
Conclusions
The S-O clip reduced the intraoperative perforation rate and procedure time, which may be useful and effective in duodenal ESD.
2.Validity of the Japanese Version of the Southampton Hand Assessment Procedure in Stroke Patients
Tomoko TANAKA ; Kensuke TAGUCHI ; Junpei SHIKANO ; Ippei MOTOMATSU ; Naoto OOTAKI ; Masaki NAKAGAWA ; Toyohiro HAMAGUCHI ; Masahiro ABO
The Japanese Journal of Rehabilitation Medicine 2019;56(6):499-509
Purpose:The Southampton Hand Assessment Procedure (SHAP) is a test of upper extremity function composed of 12 movement tasks and 14 activities of daily living tasks, and is used as an assessment battery for upper extremity prostheses. The purpose of this study is to examine its validity in clinical practice.Methods:The study included 143 patients with hemiparesis. The validity of SHAP and an existing assessment battery were compared in this study. Factors influencing the validity of differences between dominant and non-dominant hands were examined.Results:Concomitant validity was shown between the SHAP Japanese version and an existing upper extremity function evaluation method. A strong correlation with the subjective evaluation scale was obtained in cases of dominant hand paralysis.Discussion:These results suggested that SHAP is able to accurately evaluate upper extremity hemiparesis, because the difficulty level in evaluation of upper extremity function is higher than that of the Action Research Arm Test, and a ceiling effect is unlikely. Therefore, SHAP is useful in clinical practice not only for assessment of an artificial hand but also for hemiparesis with stroke. Further study to clarify the characteristics of SHAP as well as verification of reliability and standard values is warranted.
3.Validity of the Japanese Version of the Southampton Hand Assessment Procedure in Stroke Patients
Tomoko TANAKA ; Kensuke TAGUCHI ; Junpei SHIKANO ; Ippei MOTOMATSU ; Naoto OOTAKI ; Masaki NAKAGAWA ; Toyohiro HAMAGUCHI ; Masahiro ABO
The Japanese Journal of Rehabilitation Medicine 2019;():18009-
Purpose:The Southampton Hand Assessment Procedure (SHAP) is a test of upper extremity function composed of 12 movement tasks and 14 activities of daily living tasks, and is used as an assessment battery for upper extremity prostheses. The purpose of this study is to examine its validity in clinical practice.Methods:The study included 143 patients with hemiparesis. The validity of SHAP and an existing assessment battery were compared in this study. Factors influencing the validity of differences between dominant and non-dominant hands were examined.Results:Concomitant validity was shown between the SHAP Japanese version and an existing upper extremity function evaluation method. A strong correlation with the subjective evaluation scale was obtained in cases of dominant hand paralysis.Discussion:These results suggested that SHAP is able to accurately evaluate upper extremity hemiparesis, because the difficulty level in evaluation of upper extremity function is higher than that of the Action Research Arm Test, and a ceiling effect is unlikely. Therefore, SHAP is useful in clinical practice not only for assessment of an artificial hand but also for hemiparesis with stroke. Further study to clarify the characteristics of SHAP as well as verification of reliability and standard values is warranted.