1.Surgical treatment of ruptured aneruysm of the sinus of valsalva.
Eung Joong KIM ; Suk Ha HWANG ; Jin Seog PARK
The Korean Journal of Thoracic and Cardiovascular Surgery 1993;26(6):488-491
No abstract available.
Sinus of Valsalva*
2.Changes of igG subclasses in the sera of the children with Kawasaki disease.
Seog Beom CHO ; Sun Kyu PARK ; Pyoung Han HWANG ; Jung Soo KIM ; Sa Hyoung CHOI
Journal of the Korean Pediatric Society 1993;36(9):1197-1202
Kawasaki disease is an acute vasculitis of infancy and early childhood characterized by high fever, rash, mucositis, lymphadenopathy and coronary artery damage. The failure to indentify a causative organism using convetional culture and serological techniques, and the lack of response to antibiotics indicate that the disorder is probably not due to any known bacterial or viral pathogens. During the acute phase of the disease, the alterations of T and B cell functions, changes of cytokine and immunoglobulin levels have been reported. This study was performed to investigate the changes of immunoglobulins levels in patients with Kawasaki disease. IgG, IgA, IgM and IgG subclasses were measured using immunoprecipitation and EIA in the sera of patients with Kawasaki disease. The results were as follows: 1) Acute phase reactants such as CRP and ESR were significantly increased in Kawasaki patients compared to those in control patients(p<0.01). 2) Serum IgG levels in Kawasaki disease were markedly increased than those in control patients, while serum IgA and IgM levels showed no significant changes (P: No Significance). 3) IgG1 and IgG4 were predominantly increased increased in the sera of Kawasaki patients, while IgG2 and IgG3 were not significantly increased (P: No Significance). With these results, unidentified infectious organism with abnormal immune response could be suggested as an etiologic factor of Kawasaki disease.
Acute-Phase Proteins
;
Anti-Bacterial Agents
;
Child*
;
Coronary Vessels
;
Exanthema
;
Fever
;
Humans
;
Immunoglobulin A
;
Immunoglobulin G*
;
Immunoglobulin M
;
Immunoglobulins
;
Immunoprecipitation
;
Lymphatic Diseases
;
Mucocutaneous Lymph Node Syndrome*
;
Mucositis
;
Vasculitis
3.A clinical study on cardiovascular disease of children taken cardiac catheterization and cineangiography.
Gi Yeon SONG ; Seog Beom CHO ; Pyoung Han HWANG ; Chan Uhng JOO ; Jung Soo KIM
Journal of the Korean Pediatric Society 1992;35(7):949-956
No abstract available.
Cardiac Catheterization*
;
Cardiac Catheters*
;
Cardiovascular Diseases*
;
Child*
;
Cineangiography*
;
Heart Defects, Congenital
;
Humans
4.Microplate Identification System of Enterobacteriaceae.
Young UH ; Jeong Seog SON ; Gyu Yel HWANG ; In Ho JANG ; Kap Jun YOON ; Dong Min SEO
Korean Journal of Clinical Microbiology 1999;2(2):135-143
BACKGROUND: To access the accuracy and clinical usefulness of microplate identification (ID) system for the identification of Enterobacteriaceae, we compared microplate ID system with API 20E(bioMerieux, Etoile, France). METHODS: Ninety-two cultures of Enterobacteriaceae and one isolate of Aeromonas species were simultaneously identified by microplate ID system and the API 20E. Twenty biochemical tests used in microplate ID system were lactose, sucrose, and H2S in Kligler's iron agar media; indole, sucrose, raffinose, arabinose, trehalose, adonitol, dulcitol, sorbitol, cellibiose, methy-red, phenylalanine deaminase, ornithine decarboxylase, lysine decarboxylase, arginine dihydrolase, urease, and citrate in microplate; and oxidase test. The identification was obtained by considering percent likelihood(% ID), modal frequency and ID score method. RESULTS: Among the 92 cultures of Enterobacteriaceae and one isolate of Aeromonas species, agreement rate of identification according to the % ID between microplate ID system and API 20E were 90.3% to the species level and 97.8% to the genus level. CONCLUSIONS: For the identification of clinical Enterobacteriaceae isolates, the microplate ID system compares favorably with API 20E in identification accuracy and have the advantage of costsaving and easy to use.
Aeromonas
;
Agar
;
Arabinose
;
Arginine
;
Citric Acid
;
Enterobacteriaceae*
;
Galactitol
;
Iron
;
Lactose
;
Lysine
;
Ornithine Decarboxylase
;
Oxidoreductases
;
Phenylalanine
;
Raffinose
;
Ribitol
;
Sorbitol
;
Sucrose
;
Trehalose
;
Urease
5.Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity.
Hyun Ju OH ; Jung Yul CHA ; Hyung Seog YU ; Chung Ju HWANG
The Korean Journal of Orthodontics 2018;48(5):283-291
OBJECTIVE: This study was conducted to perform histomorphometric evaluations of the bone surrounding orthodontic miniscrews according to their proximity to the adjacent tooth roots in the posterior mandible of beagle dogs. METHODS: Four male beagle dogs were used for this study. Six orthodontic miniscrews were placed in the interradicular spaces in the posterior mandible of each dog (n = 24). The implanted miniscrews were classified into no loading, immediate loading, and delayed loading groups according to the loading time. At 6 weeks after screw placement, the animals were sacrificed, and tissue blocks including the miniscrews were harvested for histological examinations. After analysis of the histological sections, the miniscrews were categorized into three additional groups according to the root proximity: high root proximity, low root proximity, and safe distance groups. Differences in the bone–implant contact (BIC, %) among the root proximity groups and loading time groups were determined using statistical analyses. RESULTS: No BIC was observed within the bundle bone invaded by the miniscrew threads. Narrowing of the periodontal ligament space was observed in cases where the miniscrew threads touched the bundle bone. BIC (%) was significantly lower in the high root proximity group than in the low root proximity and safe distance groups. However, BIC (%) showed no significant differences among the loading time groups. CONCLUSIONS: Regardless of the loading time, the stability of an orthodontic miniscrew is decreased if it is in contact with the bundle bone as well as the adjacent tooth root.
Animals
;
Dogs
;
Humans
;
Male
;
Mandible
;
Periodontal Ligament
;
Tooth Root
6.Significance of PNS screening CT scan for functional endoscopicsinus surgery.
Seog In PAIK ; Ki Yeun KIM ; Hwang Min YOON ; Ki Joon SUNG
Korean Journal of Otolaryngology - Head and Neck Surgery 1992;35(6):893-900
No abstract available.
Mass Screening*
;
Tomography, X-Ray Computed*
7.The validation of Periotest values for the evaluation of orthodontic mini-implants' stability.
Jung Yul CHA ; Hyung Seog YU ; Chung Ju HWANG
Korean Journal of Orthodontics 2010;40(3):167-175
OBJECTIVE: The aim of this study was to validate the Periotest values for the prediction of orthodontic mini-implants' stability. METHODS: Sixty orthodontic mini-implants (7.0 mm x O1.45 mm; ACR, Biomaterials Korea, Seoul, Korea) were inserted into the buccal alveolar bone of 5 twelve month-old beagle dogs. Insertion torque (IT) and Periotest values (PTV) were measured at the installation procedure, and removal torque (RT) and PTV were recorded after 12 weeks of orthodontic loading. To correlate PTV with variables, the cortical bone thickness (mm) and bone mineral density (BMD) within the cortical bone and total bone area were calculated with the help of CT scanning. RESULTS: The BMD and cortical bone thickness in mandibular alveolus were significantly higher than those of the maxilla (p< 0.05). The PTV values ranged from -3.2 to 4.8 for 12 weeks of loading showing clinically stable mini-implants. PTV at insertion was significantly correlated with IT (-0.51), bone density (-0.48), cortical bone thickness (-0.42) (p< 0.05) in the mandible, but showed no correlation in the maxilla. PTV before removal was significantly correlated with RT (-0.66) (p< 0.01) in the mandible. CONCLUSIONS: These results show that the periotest is a useful method for the evaluation of mini-implant stability, but it can only be applied to limited areas with thick cortical and high density bone such as the mandible.
Animals
;
Biocompatible Materials
;
Bone Density
;
Dogs
;
Korea
;
Mandible
;
Maxilla
;
Torque
8.A case of unilateral megalencephaly.
Woo Seog KIM ; Nam Soo PARK ; Moo Young SONG ; Un Jun HYOUNG ; Jin Oh LE ; Yong Seung HWANG
Journal of the Korean Pediatric Society 1993;36(6):877-881
The unilateral megalencephaly is a rare brain malformation characterized by cerebral asymmetry and cortical dysplasia caused by faulty migration of the subependymal neuroblasts. We experienced a case of unilateral megalencephaly in a two day-old male with the chief complaint of asymmetric head appearance. Large left hemisphere with agyria, pachygyria, dilatation of lateral ventricle, and the thick cortex of the ipsilateral hemisphere were showed in brain MRL, Clinical findings in this case were intractable seizure, hemiparesis, and psychomotor retardation. A review of literatures was also presented briefly.
Brain
;
Dilatation
;
Head
;
Humans
;
Lateral Ventricles
;
Lissencephaly
;
Male
;
Malformations of Cortical Development
;
Paresis
;
Seizures
9.The effects of alveolar bone loss and miniscrew position on initial tooth displacement during intrusion of the maxillary anterior teeth: Finite element analysis.
Sun Mi CHO ; Sung Hwan CHOI ; Sang Jin SUNG ; Hyung Seog YU ; Chung Ju HWANG
The Korean Journal of Orthodontics 2016;46(5):310-322
OBJECTIVE: The aim of this study was to determine the optimal loading conditions for pure intrusion of the six maxillary anterior teeth with miniscrews according to alveolar bone loss. METHODS: A three-dimensional finite element model was created for a segment of the six anterior teeth, and the positions of the miniscrews and hooks were varied after setting the alveolar bone loss to 0, 2, or 4 mm. Under 100 g of intrusive force, initial displacement of the individual teeth in three directions and the degree of labial tilting were measured. RESULTS: The degree of labial tilting increased with reduced alveolar bone height under the same load. When a miniscrew was inserted between the two central incisors, the amounts of medial-lateral and anterior-posterior displacement of the central incisor were significantly greater than in the other conditions. When the miniscrews were inserted distally to the canines and an intrusion force was applied distal to the lateral incisors, the degree of labial tilting and the amounts of displacement of the six anterior teeth were the lowest, and the maximum von Mises stress was distributed evenly across all the teeth, regardless of the bone loss. CONCLUSIONS: Initial tooth displacement similar to pure intrusion of the six maxillary anterior teeth was induced when miniscrews were inserted distal to the maxillary canines and an intrusion force was applied distal to the lateral incisors. In this condition, the maximum von Mises stresses were relatively evenly distributed across all the teeth, regardless of the bone loss.
Alveolar Bone Loss*
;
Finite Element Analysis*
;
Incisor
;
Tooth*
10.Diagnosis of Myocardial Injury in Blunt Chest Trauma.
Sung Oh HWANG ; Kang Hyun LEE ; Sun Man KIM ; Eun Seog HONG ; Junghan YOON ; Kyung Hoon CHOE ; Boo Soo LEE
Korean Circulation Journal 1997;27(3):326-332
PURPOSE: This study was designed to evaluate diagnostic accuracy of serial electrocardiograms(ECG), myocardial band of creatinine phosphokinase(CK)(CK-MB/CK ratio) and two dimensional echocardiography(ECHO) for myocardial injury in patients with blunt chest trauma. METHODS: We prospectively investigated 54 patients(male : 38, female : 16, mean age : 41) with severe blunt chest trauma. Presence of myocardial injury was determined by increase(>0.1ug/L) of peak serum troponin T(TnT) concentration from serial mesurements. RESULTS: Among 54 patients with blunt chest trauma, 23 patients(43%) had increased peak TnT level which suggested of myocardial injury. Among 23 patients with increased TnT, abnormal ECG findings were found in 18(78%) and echocardiographic abnormalities were observed in 17(74%). Cardiovascular events in 9(39%) of 23 patients with increase Tnt. There was no cardiovascular events in patients with normal TnT. CONCLUSION: Significant proprotion of patients with blunt chest trauma had elevated TnT value which suggested of myocardial injury. We recommend echocardiagraphy and serial tracing of ECG to verify the clinical significance of elevated TnT in patients with blunt chest trauma.
Creatinine
;
Diagnosis*
;
Echocardiography
;
Electrocardiography
;
Female
;
Humans
;
Prospective Studies
;
Thorax*
;
Trinitrotoluene
;
Troponin
;
Troponin T