1.Slow flow and mural thrombus in aortic diseases: Spin-echo MR findings and their differentiation.
Jin Wook CHUNG ; Jae Hyung PARK ; Man Chung HAN
Journal of the Korean Radiological Society 1993;29(3):395-401
In order to evaluate the ability of spin-echo MR imaging to differentiate slow flow from mural thrombus in aortic diseases, we reviewed the spin-echo MR images of 13 patients with intraaortic thrombus documented by CT (N=11) or aortography (N=2). Six patients had aortic aneurysms and seven had aortic dissection. Intraaortic mural thrombi were accompanied by flow-related intraluminal signal of various patterns and extents in all 13 patients. On 10 gated MR studies, slow flow regions showed even-echo rephasing phenomenon (N=8), interslice variation of signal intensities of the intraluminal signal (N=7) and flow-related ghost artifact (N=2). However, these MR flow phenomena were obscured on two of three non-gated studies. Seven of 13 intraaortic thrombi remained hyperintense on T2-weighted second-echo images. In these circumstances, a hypointense boundary layer between slow flow and mural thrombus, which was caused by either 'boundary layer dephasing phenomenon' of slow flow or 'paramagnetic T2 shortening' of fresh clot at the edge of mural thrombus, was useful in discriminating the area of slow flow from that of mural thrombus. Proper interpretation of spin-echo MR images may obviate the need for phase display imaging or gradientecho imaging in differentiating slow flow and mural thrombus.
Aortic Aneurysm
;
Aortic Diseases*
;
Aortography
;
Artifacts
;
Humans
;
Magnetic Resonance Imaging
;
Thrombosis*
2.Slow flow and mural thrombus in aortic diseases: Spin-echo MR findings and their differentiation.
Jin Wook CHUNG ; Jae Hyung PARK ; Man Chung HAN
Journal of the Korean Radiological Society 1993;29(3):395-401
In order to evaluate the ability of spin-echo MR imaging to differentiate slow flow from mural thrombus in aortic diseases, we reviewed the spin-echo MR images of 13 patients with intraaortic thrombus documented by CT (N=11) or aortography (N=2). Six patients had aortic aneurysms and seven had aortic dissection. Intraaortic mural thrombi were accompanied by flow-related intraluminal signal of various patterns and extents in all 13 patients. On 10 gated MR studies, slow flow regions showed even-echo rephasing phenomenon (N=8), interslice variation of signal intensities of the intraluminal signal (N=7) and flow-related ghost artifact (N=2). However, these MR flow phenomena were obscured on two of three non-gated studies. Seven of 13 intraaortic thrombi remained hyperintense on T2-weighted second-echo images. In these circumstances, a hypointense boundary layer between slow flow and mural thrombus, which was caused by either 'boundary layer dephasing phenomenon' of slow flow or 'paramagnetic T2 shortening' of fresh clot at the edge of mural thrombus, was useful in discriminating the area of slow flow from that of mural thrombus. Proper interpretation of spin-echo MR images may obviate the need for phase display imaging or gradientecho imaging in differentiating slow flow and mural thrombus.
Aortic Aneurysm
;
Aortic Diseases*
;
Aortography
;
Artifacts
;
Humans
;
Magnetic Resonance Imaging
;
Thrombosis*
3.Hrombosed Aortic Dissections and Aortic Aneurysms: MRI Findings and Differential Diagnosis.
Jin Wook CHUNG ; Jae Hyung PARK ; Man Chung HAN ; Gi Seok HAN ; Yong Kyu YOON
Journal of the Korean Radiological Society 1994;30(5):853-858
PURPOSE: MRI is known to be an effective imaging modality of the aorta and its role is steadily increasing in the evaluation of acquired aortic diseases including aortic dissections and aortic aneurysms. However, differentiation of the aortic dissections with thrombosed false lumen from the aortic aneurysm with mural thrombus in MRI has not been easy. Therefore, the authors tried to find the characteristic MR featrses which would to differentiate the two diseases. MATERIALS AND METHODS: MR images of 6 patients with thrombosed aortic dissection and 7 patients with thrombosed aortic aneurysms were reviewed retrospectively and compared in regand to shape and extent of thrombus, dimension of aorta, and luminal flow signal. RESULTS: Thrombosed aortic dissections showed sharply demarcated crescent shaped aortic wall thickening of even thickness involving long segment of the aorta, whereas thrombosed aortic aneurysms showed irregular aortic wall thickening of uneven thickness localized in the short dilated segment of the aorta. Characteristically aortic aneurysm with mural thrombus showed eccentric intraluminal slow flow signal. In contrast to the signal void of the true lumen in aortic dissections, the residual lumen of the aortic aneurysm with mural thrombus revealed intraluminal signal due to slow flow. CONCLUSION: Familiarity to these MRI findings of thrombosed aortic dissections and aortic aneurysms may lead to the accurate differential diagnosis in majority of cases.
Aorta
;
Aortic Aneurysm*
;
Aortic Diseases
;
Diagnosis, Differential*
;
Humans
;
Magnetic Resonance Imaging*
;
Phenobarbital
;
Recognition (Psychology)
;
Retrospective Studies
;
Thrombosis
4.Transarterial chemoembolization through collateral vessels in hepatocellular carcinoma.
Ji Hye KIM ; Joon Koo HAN ; Jin Wook CHUNG ; Jae Hyung PARK ; Man Chung HAN
Journal of the Korean Radiological Society 1993;29(6):1220-1228
We performed 70 proceudres of transarterial chemoembolization (TAE) through extrahepatic collateral vessels (n=27) or parasitic feeders (n=18) in 45 hepatocellular carcinoma patients. The collaterals developed after interruption of the hapatic artery due to repeated TAE(n=17), surgical ligation(n=7) and primary celiac occlusion (n=3). Radiologic findings suggesting the existence of parasitic or collateral supply for hepatocellular carcinoma were 1) a focal defect of Lipiodol retention on CT or plain film after TAE via the hepatic artery, 2) dilated and tortuous vessels around the mass on angiography, 3) persistent elevation of the level of serum alpha fetoprotein or continuous clinical symptoms in spite of sufficient devascularization of the tumor via the hepatic artery, and 4) radiological findings of direct invasion into adjacent organ. The sites of the catheter placement were the inferior phrenic artery (n=19), omental branches (n=16), periportal collaterals (n=6), pancreaticodenal arcade (n=3), gastroduodenal artery (n=3), internal mammary artery (n=2), intercostal artery (n=2), lateral thoracic artery (n=1), bronchial artery(n=1), and colic branches(n=1). Masses feeded by the inferior phrenic and chest wall collaterals were usually located at the dome area of the liver, and the omental and gastroduodenal collaterals developed in the masses located at the inferior tip of the liver. After TAE via collateral vessels, 37 patients underwent follow-up study. In 18 cases(48%), the tumor favorably responded to TAE. Specific complications of collateral TAE were epigastric soreness (n=10), severe shoulder pain (n=4), and embolization of the spinal artery during embolization through the intercostal artey (n=1). In conclusion, various extrahepatic collaterals are important alternative or additional routes for effective chemoembolization in patients with advanced hepatoma, and early recognition of the parasitic supply and the effort to perform TAE via collaterals is very important for effective management of the patients with the hepatoma.
alpha-Fetoproteins
;
Angiography
;
Arteries
;
Carcinoma, Hepatocellular*
;
Catheters
;
Colic
;
Ethiodized Oil
;
Follow-Up Studies
;
Hepatic Artery
;
Humans
;
Liver
;
Mammary Arteries
;
Shoulder Pain
;
Thoracic Arteries
;
Thoracic Wall
5.Transjugular intrahepatic portsystemic shunt.
Jae Hyung PARK ; Joon Koo HAN ; Jin Wook CHUNG ; Man Chung HAN
Journal of the Korean Radiological Society 1992;28(3):393-398
As a new interventional procedure for the control of variceal bleeding, a portosystemic shunt can be established with the installment of metallic stent through the transjugular approach. In order to evaluate the clinical usefulness of the procedure, transjugular intrahepatic portosystemic chunt procedure were performed in 5 patients with variceal bleeding due to liver cirrhosis. The metallic stents were mainly a self expandable Wallstent(Schneider, Switzerland). An 8 to 10 mm shunt was formed by the insertion of the stent and balloon dilatation after puncture of the proximal portal vein from the right or middle hepatic vein. The patency of the shunt was proven by portography after the procedure. The portal pressure measured in 3 patients before and after the procedure improved with decrease from 31 mmHg to 25 mmHg. The procedure failed in 1 patient due to preexsisting portal vein thrombosis. During the follow-up period from 1 month to 4 months, shunts were patent in all 4 patients. However, hepatic encephalopathy occured in one patient one week following the procedure. Though the follow-up period was not long enough for full evaluation. We found the transjugular intrahepatic portosystemic shunt was a safe and effective procedure for the control of variceal bleeding by lowering the portal pressure. For the appropriate application for this procedure, the optimal size of the shunt and optimal degree of the resultant decompression are yet to be determined in the future.
Decompression
;
Dilatation
;
Esophageal and Gastric Varices
;
Follow-Up Studies
;
Hepatic Encephalopathy
;
Hepatic Veins
;
Humans
;
Liver Cirrhosis
;
Portal Pressure
;
Portal Vein
;
Portasystemic Shunt, Surgical
;
Portography
;
Punctures
;
Stents
;
Venous Thrombosis
6.The use of self expandable metallic stent in the management of malignant biliary obstruction.
Joon Koo HAN ; Byung Ihn CHOI ; Jin Wook CHUNG ; Jae Hyung PARK ; Gi Seok HAN ; Man Chung HAN
Journal of the Korean Radiological Society 1993;29(3):457-463
Self expandable metallic stent is a good alternative of percutaneous transhepatic biliary drainage because it can eliminate numerous problems caused by external drainage catheter, such as tube dislodgement, bile leakage and psychotic problems. Authors analyzed initial results of self expandable metallic stents used in the patients with malignant biliary obstruction to evaluate the efficacy of the procedure and to find the technical problems in the procedure. Self expandable metallic stents were inserted in 14 patients: three with recurrent stomach cancer: there with gallbladder cancer: seven with Klatskin tumor: one with common duct cancer. Gianturco type stent was used in 9 cases ans Wallstent was used in 2 cases. In remaining three cases, both Z-stent and Wallstent were used in the same patient. The average period of follow up was 104 days (4-409). In 13 cases, the patency of the bile duct was restored by the stent (technical success: 92.9%). Occlusions of the stent were found in two cases, after two and 13 months, respectively. Causes of failure and stent occlusion were associated duodenal obstruction, tumor overgrowth and shortening of Wallstent. In remaining 11 patients, one patient was lost to follow up an 10 patients did not show recurrent jaundice until death or last follow up. There was no major complication related to the procedure. The insertion of self expandable metallic stent is a safe procedure and call eliminate major disadvantages of PTBD. Overstenting, overlapping land evaluation of associated GI tract obstruction is crucial for obtaining technical success and long-term patency.
Bile
;
Bile Ducts
;
Catheters
;
Drainage
;
Duodenal Obstruction
;
Follow-Up Studies
;
Gallbladder Neoplasms
;
Gastrointestinal Tract
;
Humans
;
Jaundice
;
Klatskin Tumor
;
Lost to Follow-Up
;
Self Expandable Metallic Stents*
;
Stents
;
Stomach Neoplasms
7.The use of self expandable metallic stent in the management of malignant biliary obstruction.
Joon Koo HAN ; Byung Ihn CHOI ; Jin Wook CHUNG ; Jae Hyung PARK ; Gi Seok HAN ; Man Chung HAN
Journal of the Korean Radiological Society 1993;29(3):457-463
Self expandable metallic stent is a good alternative of percutaneous transhepatic biliary drainage because it can eliminate numerous problems caused by external drainage catheter, such as tube dislodgement, bile leakage and psychotic problems. Authors analyzed initial results of self expandable metallic stents used in the patients with malignant biliary obstruction to evaluate the efficacy of the procedure and to find the technical problems in the procedure. Self expandable metallic stents were inserted in 14 patients: three with recurrent stomach cancer: there with gallbladder cancer: seven with Klatskin tumor: one with common duct cancer. Gianturco type stent was used in 9 cases ans Wallstent was used in 2 cases. In remaining three cases, both Z-stent and Wallstent were used in the same patient. The average period of follow up was 104 days (4-409). In 13 cases, the patency of the bile duct was restored by the stent (technical success: 92.9%). Occlusions of the stent were found in two cases, after two and 13 months, respectively. Causes of failure and stent occlusion were associated duodenal obstruction, tumor overgrowth and shortening of Wallstent. In remaining 11 patients, one patient was lost to follow up an 10 patients did not show recurrent jaundice until death or last follow up. There was no major complication related to the procedure. The insertion of self expandable metallic stent is a safe procedure and call eliminate major disadvantages of PTBD. Overstenting, overlapping land evaluation of associated GI tract obstruction is crucial for obtaining technical success and long-term patency.
Bile
;
Bile Ducts
;
Catheters
;
Drainage
;
Duodenal Obstruction
;
Follow-Up Studies
;
Gallbladder Neoplasms
;
Gastrointestinal Tract
;
Humans
;
Jaundice
;
Klatskin Tumor
;
Lost to Follow-Up
;
Self Expandable Metallic Stents*
;
Stents
;
Stomach Neoplasms
8.Radiation Exposure of Operator during Various Interventional Procedures.
Jin Wook CHUNG ; Jae Hyung PARK ; Joon Koo HAN ; In Kyu YU ; Wee Saing KANG
Journal of the Korean Radiological Society 1994;30(2):265-270
PURPOSE: To investigate the levels of radiation exposure of an operator which may be influenced by the wearing an apron, type of procedure, duration of fluoroscopy and operator's skill during various interventional procedures MATERIALS AND METHODS: Radiation doses were measured both inside and outside the apron(0.5mm lead equivalent) of the operator by a film badge monitoring method and the duration of fluoroscopy was measured in 96 procedures prospectively. The procedures were 30 transcatheter arterial embolizations (TAE), 25 percutaneous transhepatic biliary drainages (PTBD), 16 stone removals (SR), 15 percutaneous needle aspirations (PCNA) and 10 percutaneous nephrostomies(PCN). To assess the difference of exposure by the operator's skill, the procedures of TAE and PTBD were done separately by groups of staffs and residents. RESULTS: Average protective effect of the apron was 72.8%. Average radiation exposure(unit:micro Sv/procedure) was 23.3 in PTBD by residents, 10.0 in PTBD by staffs, 10.0 in SR, 8.7 in TAE by residents, 7.3 in TAE by staffs, 9.0 in PCN and 6.0 in PCNA. Average radiation exposure of residents were 1.9 times greater than those of staffs. CONCLUSION: Radiation exposure was not proportionally related to the duration of fiuoroscopy, but influenced by wearing an apron, various types o[procedure and operator's skills.
Aspirations (Psychology)
;
Film Dosimetry
;
Fluoroscopy
;
Needles
;
Pregnenolone Carbonitrile
;
Proliferating Cell Nuclear Antigen
;
Prospective Studies
9.Pathology of Cardiac Anomalies and Systemic Edema in the Murine Fetus with Trisomy 16.
Young Mee HAN ; Jae Hyung YOO ; Jung Yun CHOI ; Jeong Wook SEO
Korean Circulation Journal 1999;29(6):612-624
BACKGROUND: Trisomy 16 in mice is considered to be an animal model for Down's syndrome in human. We studied the morphologic characteristics of the heart and the edema, and their significance to the teratogenesis in this animal model. METHODS: A total of 30 dams were sacrificed to bear 125 (61.9%) normal fetuses 35 (17.3%) abnormal fetuses and 42 (20.8%) resorptions. Cytogenetic study and morphological examination were performed using microdissection agar-mount sectioning histologic examination and scanning electron microscope. RESULTS: The crown-rump length was significantly shorter in abnormal (trisomic fetuses) than the normal (eusomic) fetuses. Trisomic fetuses showed massive edema at the back from the vertex to the lumbar area. Four-chamber view section of the agar-mount and histologic section showed a common atrioventricular valve bridging the left and the right atrioventricular junction. Scanning electron microscopic examination on atrioventricular valves showed three types of atrioventricular valves:five cases with common atrioventricular orifice, three cases with partitioned atrioventricular orifice and two cases with atresia of the right atrioventricular orifice. CONCLUSION: This study confirmed the presence of massive edema and cardiac anomalies in the mouse with trisomy 16. But there was morphologic diversity of cardiac anomaly in this model.
Animals
;
Crown-Rump Length
;
Cytogenetics
;
Down Syndrome
;
Edema*
;
Endocardial Cushion Defects
;
Fetus*
;
Heart
;
Humans
;
Hydrops Fetalis
;
Mice
;
Microdissection
;
Models, Animal
;
Pathology*
;
Teratogenesis
;
Trisomy*
10.Persistent high serum bilirubin level after percutaneous transhepatic biliary drainage: analysis of 32 cases
In Wook CHOO ; Byung Ihn CHOI ; Jae Hyung PARK ; Man Chung HAN ; Chu Wan KIM
Journal of the Korean Radiological Society 1986;22(6):1027-1033
The aim of percutaneous transhepatic biliary drainage(PTBD) is to decrease serum bilirubin level and promoteliver function in patient with biliary tract disease, especially obstruction by malignant disese. But somepatients showed persistent high serum bilirubin level or higher than pre-PTBD level. Percutaneous transhepaticbiliary drainage was performed in 341 patients of obstructive jaundice for 5 years from July, 1981 to July, 1986at departement of radiology, Seoul Natinal University Hospital. Follow up check of the serum bilibrubin level waspossible in 188 patients. Among them the authors analysed 32 patients who showed persistent high serum bilirubinlevel after PTBD. The results were as follows: 1. The male to female ratio was 3.4:1 and the age ranged from 33 to 75. 2. The causes of obstructive jaundice included 30 malignant diseases and 2 benign diseases. Malignant diseasewere 16 cases of bile duct carcinoma, 7 cases of pancreatic cancer and 7 cases of matastasis from stomach, colonand uterine cervix. Benign disease were 1 cases of common hepatic duct stone and 1 case of intrahepatic ductstones. 3. The msot common level of obstruction was trifurcation in 17 cases. 4. The most common indication ofPTBD was palliative drainage of obstruciton secondary to malignant tumor in 28 cases. 5. Change of serujmbilirubin level ratio(post-PTBD level) was 1.28, 1.22, 1.38, 1.51 in serial period of 1–3 days, 4–6 days, 1–2 week 2–3 week after PTBD. 6. Causes of persistent high serum bilirubin level after PTBD were 12 cases of partialdrainage of intrahepatic bile, 13 cases of hepatic dysfunction including 9 cases of metastatic nodule, 2 cases ofbiliary cirrhosis, 2 cases of multiple liver abscess, and 7 cases of poor function of cather including 4 cases ofhemobilia, 1 case of multiple intrahepatic stones, pyobilia and intraheptic Clonorchis sinensis.
Bile
;
Bile Ducts
;
Biliary Tract Diseases
;
Bilirubin
;
Cervix Uteri
;
Clonorchis sinensis
;
Drainage
;
Female
;
Fibrosis
;
Follow-Up Studies
;
Hepatic Duct, Common
;
Humans
;
Jaundice, Obstructive
;
Liver Abscess
;
Male
;
Pancreatic Neoplasms
;
Seoul
;
Stomach