1.A Study on the Effectiveness of Clocortolone Pivalate (Purantix) Gream on Certain Common Skin Diseases.
Korean Journal of Dermatology 1978;16(4):311-317
In order to evaluate the effectiveness of clocortolone pivalate(Purantix) on corticosteroid responsive dermatoses, a symmetical paired. comparison technique was performed using 0. 1% clocortolone pivalate and 0. 025% triamcinolone acetonide creams. During the pericd of 7 months from September 1977 to March 1978, 37 patients with bilateral lesions of contact dermatitis, seborrheic dermatitis atopic dermatitis, lichen simplex chronicus and psoriasis were selected and treated with afore mentioned drugs, In the 15 psoriatic patients, clocrtolone pivalate was superior in 3, triamcinolone acetonide was superior in 2, 4oth drugs were equally effective in 10. In the evaluation of all 37 patients clocortolone pivalate was superior in 8, triamcinolone acetonide was sureior in 3, both drugs were equally effective in 26. The overall superiority of clocortolone pivalate to triamcinolone acetonide was non significant, There was no side effects with either drug. The simplicity of the vasoconstriction tcst has led to its general use in the study of the potency of new topical steroids. In the 6h occluded single-application vasocon-strictor test performed on 40 healthy students, there was no significant difference between clocortolone pivalate and triamcinolone acetonide, but they significantly d.ifferent from 1% hydrocortisone and the control; a simple ointment base(p<0.01).
Dermatitis, Atopic
;
Dermatitis, Contact
;
Dermatitis, Seborrheic
;
Humans
;
Hydrocortisone
;
Neurodermatitis
;
Psoriasis
;
Skin Diseases*
;
Skin*
;
Steroids
;
Triamcinolone Acetonide
;
Vasoconstriction
2.Microleakage and water stability of resin cements.
Sun Young CHOI ; Sun Hyung LEE ; Jae Ho YANG ; Jung Suk HAN
The Journal of Korean Academy of Prosthodontics 2003;41(3):369-378
STATEMENT OF PROBLEM: Recently, resin cements have become more widely used and have been accepted as prominent luting cements. Current resin cements exhibit less microleakage than conventional luting cements. However, the constant contact with water and exposure to occlusal forces increase microleakage even in resin cements inevitably. Most bonding resins have been modified to contain a hydrophilic resin such as 2-hydroxyethylmethacrylate (HEMA) to overcome some of the problems associated with the hydrophobic nature of bonding resins. By virtue of these modifications, bonding resins absorb a significant amount of water, and there may also be significant stresses at bonding interfaces, which may adversely affect the longevity of restorations. Therefore the reinforcement of water stability of resin cement is indispensable in future study. PURPOSE: This study was conducted to examine the influence of water retention on microleakage of two resin cements over the period of 6 months. MATERIALS AND METHODS: 32 ex acted human teeth were used to test the microleakage of a single full veneer crown. Two resin cements with different components and adhesive properties - Panavia F (Kuraray Co., Osaka, Japan) and Super-Bond C&B (Sun Medical Co., Kyoto, Japan)- were investigated. The storage medium was the physiological saline solution changed every week for 1 month, 3 months, and 6 months. One group was tested after storage for 1 day. At the end of the each storage period, all specimens were exposed to thermocycling from 5.C to 55.C of 500 cycles and chewing simulation of 50,000 cycles, and then stained with 50% silver nitrate solution. The linear penetration of microleakage was measured using a stereoscopic microscope at x 40 magnification and a digital traveling micrometer with an accuracy of +/-3 um. Values were analyzed using two-way ANOVA test, Duncan's multiple range tests (DMRT). RESULTS: Statistically significant difference of microleakage was shown in the 3-month group compared with the 1-day or 1-month group in bot systems (p<0.05) and there were statistically significant differences in microleakage between the 3-month group and the 6-month group in both systems (p<0.05). The two systems showed different tendency in the course of increased microleakage during 3 months. In Panavia F, microleakage increased slowly throughout the periods. In Super-Bond C&B, there was no significant increase of microleakage for 1 month, but there was statistically significant increase of microleakage for the next 2 months. For the mean microleakage for each period, in the 3-month group, microleakage of Super-Bond C&B was significantly greater than that of Panavia F. On the other hand, in the 6-month group, microleakage of Panavia F was significantly greater than that of Super-Bond C&B (p<0.05). CONCLUSION: Within the limitation of this study, water retention of two different bonding systems influence microleakage of resin cements. Further studies with the longer observation periods in viro are required in order to investigate water stabilty and the bonding durability of the resin cement.
Adhesives
;
Bite Force
;
Crowns
;
Hand
;
Humans
;
Longevity
;
Mastication
;
Resin Cements*
;
Silver Nitrate
;
Sodium Chloride
;
Tooth
;
Virtues
;
Water*
3.The evaluation of the combined use of serum ?hCG and ultrasound in diagnosis of ectopic pregnancy.
Jong Suk KO ; Ha Bong KIM ; Myeong Suk LEE ; Hyung Sun RYU ; Ho Jun CHOI ; Seung Kwan SHIN
Korean Journal of Obstetrics and Gynecology 1993;36(7):1407-1415
No abstract available.
Diagnosis*
;
Female
;
Pregnancy
;
Pregnancy, Ectopic*
;
Ultrasonography*
4.FRACTURE TOUGHNESS OF VARIOUS CORE MATERIALS.
Shin Won LEE ; Sun Hyung LEE ; Jae Ho YANG ; Jung Suk HAN ; Jai Bong LEE
The Journal of Korean Academy of Prosthodontics 2001;39(6):682-697
This investigation evaluated the fracture toughness (KIC) of eight currently available core materials, and relate the fracture toughness value to fractography analysis and surface characteristics using a atomic force microscope (AFM). Single-edge notched (SEN) test specimens (n=10) and compact tension (CT) test specimens (n=10) were prepared conforming to the ASTM Standard E-399 for a high copper amalgam, three composite core materials (Core-Max II, Core Paste, Bisfil Core), two reinforced composite core materials (Ti-Core, Ti-Core Natural), a resin-modified glass ionomer core material (Vitremer), and a conventional glass ionomer core material (Ketac-Molar). The specimens were tested with an Instron Universal Testing Machine. The maximum loads were measured to calculate the fracture toughness (KIC). Thereafter, fracture surfaces of SEN specimens of each material were investigated for fractography analysis using scanning electron microscope. And, disc-shaped specimens with 1mm thickness were fabricated for each material and were investigated under AFM for surface morphology analysis. The results were as follows : 1. Bisfil Core showed the highest mean fracture toughness regardless of test methods. 2. For the tooth-colored materials, Ti-Core Natural exhibited the highest fracture toughness. 3. Ketac Molar showed a significantly low fracture toughness when compared with the amalgam and the composite resin core materials (p<0.05). 4. The fracture toughness values obtained with the single-edge notched test, except Ketac Molar, were higher than those obtained in the compact tension test. 5. SEM revealed that the fracture surface of high fracture toughness material was rougher than that of low fracture toughness material. 6. AFM revealed that the surface particles of the composite resins were smaller in size, with a lower surface roughness than the glass ionomer core materials.
Composite Resins
;
Copper
;
Glass
;
Molar
5.COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF EMPRESS 2 CERAMIC AND TARGIS-VECTRIS CROWN.
Young Joo CHA ; Jae Ho YANG ; Sun Hyung LEE ; Jung Suk HAN
The Journal of Korean Academy of Prosthodontics 2001;39(6):599-610
Due to an increasing interest in esthetics and concerns about toxic and allergic reactions to certain alloys, patients and dentists have been looking for metal-free tooth-colored restorations. Recent improvement in technology of new all-ceramic materials and composite materials has broadened the options for esthetic single crown restorations. The aim of this investigation was to study the fracture strength of the metal-free posterior single crowns fabricated using two recently introduced systems, Empress 2 ceramic and Targis-Vectris. Forty premolar-shaped stainless steel dies with the 1mm-wide circumferential shoulder were prepared. Ten cylindrical crowns having a diameter of 8.0mm and total height of 7.5mm were fabricated for each crown system respectively (PFM, Empress staining technique, Empress 2 layering technique, and Targis-Vectris). The crowns were filled with cement and placed on the stainless steel dies with firm finger pressure. The crowns were then stored in distilled water at room temperature for 24 hours before testing. The crowns were tested for fracture strength in an Instron universal testing machine (Instron 6022). With a crosshead speed of 1mm/min the center of the occlusal surface of the crown was loaded using a 4mm-diameter stainless steel ball until fracture occurred. The fracture surfaces of the crowns were gold coated and examined using scanning electron microscopy (Jeol JSM-840 Joel Ltd., Akishima, Tokyo, Japan). Within the parameters of this study the following conclusions were drawn: 1. The mean fracture strength for PFM crowns was 5829(+/-906)N; for Empress staining technique the fracture strength was 1697(+/-604)N; for Empress 2 Layering technique the fracture strength was 1781N(+/-400)N, and the fracture strength for Targis-Vectris was 3093(+/-475)N. 2. The fracture strength of the PFM crowns was significantly higher than that of the Empress 2 and the Targis-Vectris crowns (P<0.05). 3. The fracture strength of the Targis-Vectris crowns was significantly higher than that of the Empress 2 crowns (P<0.05). 4. No statistical difference was found when Empress staining technique was compared with Empress 2 layering technique. 5. The SEM image of fracture surface of Empress 2 crown showed a very dense microstructure of the lithium disilicate crystals and the SEM image of fracture surface of Targis-Vectris crown showed indentations of Vectris and some fibers torn off from Vectris.
Alloys
;
Ceramics*
;
Crowns*
;
Dentists
;
Esthetics
;
Fingers
;
Humans
;
Hypersensitivity
;
Lithium
;
Microscopy, Electron, Scanning
;
Shoulder
;
Stainless Steel
;
Water
6.Idiopathic Granulomatous Appendicitis: A case report.
In Hyung PARK ; Woo Jin KIM ; Min Suk HAN ; Soo Hang KIM ; Jae Hyung SUN ; Jin Suk PARK ; Jae Hong PARK ; Soong LEE ; Woong LEE ; Sun Phil KIM
Journal of the Korean Society of Coloproctology 2006;22(5):337-340
Crohn's disease is a chronic condition characterized by a non-specific granulomatous necrosis involving potentially any location in the alimentary tract, but a primary lesion confined to the appendix alone is very rare. It is difficult to discriminate Crohn's appendicitis from acute appendicitis preoperatively because of their clinical similarities. Because Crohn's disease confined to the appendix has a more favorable prognosis than typical Crohn's disease, it is considered a separate disease from Crohn's disease. Recently, the term idiopathic granulomatous appendicitis has gained wide acceptance as a distinct disease entity. We experienced a case of Crohn's disease giving rise to appendicitis or idiopathic granulomatous appendicitis and report a case with a review of the literature.
Appendicitis*
;
Appendix
;
Crohn Disease
;
Necrosis
;
Prognosis
7.Experimental Study on Transverse-Axis Neovascularization of Acellular Dermal Matrix Using Platelet-Rich Plasma
Hyung Suk YI ; Ho Young IM ; Jin Hyung PARK ; Yoon Soo KIM ; Sun-Ju OH ; Hong Il KIM
Journal of Wound Management and Research 2024;20(1):29-35
Background:
Acellular dermal matrices (ADMs) have shown promise in promoting tissue regeneration; however, their integration in challenging cases with limited vertical-axis neovascularization remains difficult. This study investigates whether clinically meaningful transverse-axis neovascularization is identified in ADM engraftment and whether this can be further accelerated by platelet-rich plasma (PRP).
Methods:
ADM and PRP-soaked ADM were implanted into New Zealand rabbits, and histological analysis was performed at different periods to compare neovascularization.
Results:
Histological analysis revealed that among 32 biopsy sites, there was transverse-axis neovascularization with an average length of 606.89 μm. When divided into two groups for assessing the impact of PRP on transverse-axis neovascularization, the extent of such neovascularization was measured as 582.99 μm in the control group and 630.79 μm in the experimental group. However, there was no statistically significant difference between the two groups (P=0.693).
Conclusion
The results of the present study indicate that achieving meaningful transverse-axis neovascularization in implanted ADMs remains a challenge, warranting further investigation into ADM structure and vertical-axis neovascularization.
8.Experimental Study on Transverse-Axis Neovascularization of Acellular Dermal Matrix Using Platelet-Rich Plasma
Hyung Suk YI ; Ho Young IM ; Jin Hyung PARK ; Yoon Soo KIM ; Sun-Ju OH ; Hong Il KIM
Journal of Wound Management and Research 2024;20(1):29-35
Background:
Acellular dermal matrices (ADMs) have shown promise in promoting tissue regeneration; however, their integration in challenging cases with limited vertical-axis neovascularization remains difficult. This study investigates whether clinically meaningful transverse-axis neovascularization is identified in ADM engraftment and whether this can be further accelerated by platelet-rich plasma (PRP).
Methods:
ADM and PRP-soaked ADM were implanted into New Zealand rabbits, and histological analysis was performed at different periods to compare neovascularization.
Results:
Histological analysis revealed that among 32 biopsy sites, there was transverse-axis neovascularization with an average length of 606.89 μm. When divided into two groups for assessing the impact of PRP on transverse-axis neovascularization, the extent of such neovascularization was measured as 582.99 μm in the control group and 630.79 μm in the experimental group. However, there was no statistically significant difference between the two groups (P=0.693).
Conclusion
The results of the present study indicate that achieving meaningful transverse-axis neovascularization in implanted ADMs remains a challenge, warranting further investigation into ADM structure and vertical-axis neovascularization.
9.Experimental Study on Transverse-Axis Neovascularization of Acellular Dermal Matrix Using Platelet-Rich Plasma
Hyung Suk YI ; Ho Young IM ; Jin Hyung PARK ; Yoon Soo KIM ; Sun-Ju OH ; Hong Il KIM
Journal of Wound Management and Research 2024;20(1):29-35
Background:
Acellular dermal matrices (ADMs) have shown promise in promoting tissue regeneration; however, their integration in challenging cases with limited vertical-axis neovascularization remains difficult. This study investigates whether clinically meaningful transverse-axis neovascularization is identified in ADM engraftment and whether this can be further accelerated by platelet-rich plasma (PRP).
Methods:
ADM and PRP-soaked ADM were implanted into New Zealand rabbits, and histological analysis was performed at different periods to compare neovascularization.
Results:
Histological analysis revealed that among 32 biopsy sites, there was transverse-axis neovascularization with an average length of 606.89 μm. When divided into two groups for assessing the impact of PRP on transverse-axis neovascularization, the extent of such neovascularization was measured as 582.99 μm in the control group and 630.79 μm in the experimental group. However, there was no statistically significant difference between the two groups (P=0.693).
Conclusion
The results of the present study indicate that achieving meaningful transverse-axis neovascularization in implanted ADMs remains a challenge, warranting further investigation into ADM structure and vertical-axis neovascularization.
10.Experimental Study on Transverse-Axis Neovascularization of Acellular Dermal Matrix Using Platelet-Rich Plasma
Hyung Suk YI ; Ho Young IM ; Jin Hyung PARK ; Yoon Soo KIM ; Sun-Ju OH ; Hong Il KIM
Journal of Wound Management and Research 2024;20(1):29-35
Background:
Acellular dermal matrices (ADMs) have shown promise in promoting tissue regeneration; however, their integration in challenging cases with limited vertical-axis neovascularization remains difficult. This study investigates whether clinically meaningful transverse-axis neovascularization is identified in ADM engraftment and whether this can be further accelerated by platelet-rich plasma (PRP).
Methods:
ADM and PRP-soaked ADM were implanted into New Zealand rabbits, and histological analysis was performed at different periods to compare neovascularization.
Results:
Histological analysis revealed that among 32 biopsy sites, there was transverse-axis neovascularization with an average length of 606.89 μm. When divided into two groups for assessing the impact of PRP on transverse-axis neovascularization, the extent of such neovascularization was measured as 582.99 μm in the control group and 630.79 μm in the experimental group. However, there was no statistically significant difference between the two groups (P=0.693).
Conclusion
The results of the present study indicate that achieving meaningful transverse-axis neovascularization in implanted ADMs remains a challenge, warranting further investigation into ADM structure and vertical-axis neovascularization.