1.Histologic evaluation and removal torque analysis of nano- and microtreated titanium implants in the dogs.
Seok AHN ; Mong Sook VANG ; Hong So YANG ; Sang Won PARK ; Hyun Pil LIM
The Journal of Advanced Prosthodontics 2009;1(2):75-84
STATEMENT OF PROBLEM: A number of studies about the nano-treated surfaces of implants have been conducting along with micro-treated surfaces of implants. PURPOSE: The purpose of this study was to get information for the clinical use of nano-treated surfaces compared with micro-treated surfaces by measuring removal torque and analyzing histological characteristics after the placement of various surface-treated implants on femurs of dogs. MATERIAL AND METHODS: Machined surface implants were used as a control group. 4 nano-treated surface implants and 3 micro-treated surface implants [resorbable blast media surface (RBM), sandblast and acid-etched surface (SAE), anodized RBM surface] were used as experimental groups. Removal torque values of implants were measured respectively and the histological analyses were conducted on both 4weeks and 8weeks after implant surgery. The surfaces of removed implants after measuring removal torque values were observed by scanning electron microscopy (SEM) at 8 weeks. RESULTS: 1. Removal torque values of the nano-treated groups were lower than those of micro-treated groups. 2. Removal torque values were similar in the anodized RBM surface groups. 3. On the histological views, there was much of bone formation at 8 weeks, but there was no difference between 4 and 8 weeks, and between the types of implant surfaces as well. CONCLUSION: It is suggested that implant topography is more effective in removal torque test than surface chemistry. To get better clinical result, further studies should be fulfilled on the combined effect of surface topography and chemistry for the implant surface treatments.
Animals
;
Dogs
;
Femur
;
Microscopy, Electron, Scanning
;
Osteogenesis
;
Titanium
;
Torque
2.The analysis of cost-effectiveness of implant and conventional fixed dental prosthesis.
June Sang CHUN ; Alix HAR ; Hyun Pil LIM ; Hoi Jeong LIM
The Journal of Advanced Prosthodontics 2016;8(1):53-61
PURPOSE: This study conducted an analysis of cost-effectiveness of the implant and conventional fixed dental prosthesis (CFDP) from a single treatment perspective. MATERIALS AND METHODS: The Markov model for cost-effectiveness analysis of the implant and CFDP was carried out over maximum 50 years. The probabilistic sensitivity analysis was performed by the 10,000 Monte-Carlo simulations, and cost-effectiveness acceptability curves (CEAC) were also presented. The results from meta-analysis studies were used to determine the survival rates and complication rates of the implant and CFDP. Data regarding the cost of each treatment method were collected from University Dental Hospital and Statistics Korea for 2013. Using the results of the patient satisfaction survey study, quality-adjusted prosthesis year (QAPY) of the implant and CFDP strategy was evaluated with annual discount rate. RESULTS: When only the direct cost was considered, implants were more cost-effective when the willingness to pay (WTP) was more than 10,000 won at 10th year after the treatment, and more cost-effective regardless of the WTP from 20th year after the prosthodontic treatment. When the indirect cost was added to the direct cost, implants were more cost-effective only when the WTP was more than 75,000 won at the 10th year after the prosthodontic treatment, more than 35,000 won at the 20th year after prosthodontic treatment. CONCLUSION: The CFDP was more cost-effective unless the WTP was more than 75,000 won at the 10th year after prosthodontic treatment. But the cost-effectivenss tendency changed from CFDP to implant as time passed.
Dental Prosthesis*
;
Korea
;
Patient Satisfaction
;
Prostheses and Implants
;
Prosthodontics
;
Survival Rate
3.The effect of Zirconium Nitride coating on shear bond strength with denture base resin in Co-Cr alloy and titanium alloy.
Chan PARK ; Kyoung Hun LEE ; Hyun Pil LIM
Journal of Dental Rehabilitation and Applied Science 2016;32(3):194-201
PURPOSE: The purpose of this study was to evaluate of Zirconium Nitride (ZrN) coating on shear bond strength with denture base resin in Co-Cr and Ti-6Al-4V alloy. MATERIALS AND METHODS: Co-Cr and Ti-6Al-4V alloy disks (10 mm in diameter, 2.5 mm in thickness; each other: n = 14) were prepared and divided with 2 groups each other by ZrN coating. After primer was applied to disks surface, denture base resin with diameter 6 mm, height 5 mm was bonded on metal disk surface. After surface roughness was measured by Profiler, shear bond strength was determined with Universal testing machine and analyzed with two-way ANOVA. The specimen surfaces and failure mode were examined using a scanning electron microscope. RESULTS: ZrN coated groups showed significantly higher rough surface than non-coated groups (P < 0.05). Irrespective of alloy materials, shear bond strength of ZrN coated groups were lower than non-coated groups (P < 0.001). The scanning electron microscope (SEM) of ZrN coated groups showed mixed and adhesive fractures. CONCLUSION: ZrN coating weakened bonding strength between denture base resin and Co-Cr, Ti-6Al-4V alloy.
Adhesives
;
Alloys*
;
Denture Bases*
;
Dentures*
;
Titanium*
;
Zirconium*
4.Use of Nicardipine and Esmolol in the Anesthetic Management for Bilateral Pheochromocytoma: A case report.
Pil Jae LIM ; Hyun Jeong KWAK ; Ho Sung KWAK
Korean Journal of Anesthesiology 2003;44(1):128-131
Pheochromocytoma stems from the chromaffin cell and mostly is located in the adrenal medulla. It is an important cause of secondary hypertension due to correction of hypertension by a resection of the tumor. Because it produces and secretes catecholamine, it bothers anesthesiologists with excessive hypertension, tachycardia and arrhythmia during the anesthetic period. Therefore, anesthetic management is directed to avoid these conditions. We report a case of bilateral pheochromocytoma successfully managed intraoperatively with an infusion of nicardipine and an intermittent esmolol injection.
Adrenal Medulla
;
Arrhythmias, Cardiac
;
Chromaffin Cells
;
Hypertension
;
Nicardipine*
;
Pheochromocytoma*
;
Tachycardia
5.Shear bond strength of composite resin to titanium according to various surface treatments.
Seung Yun LEE ; Mong Sook VANG ; Hong So YANG ; Sang Won PARK ; Ha Ok PARK ; Hyun Pil LIM
The Journal of Advanced Prosthodontics 2009;1(2):68-74
STATEMENT OF PROBLEM: When veneering composite resin-metal restoration is prepared, the fact that bond strength between Ti and composite resin is relatively weak should be considered. PURPOSE: The purpose of this study is to evaluate the shear bond strength between the veneering composite resin and commercial pure (CP) Ti / Ti-6Al-4V alloy according to the method of surface treatment. MATERIAL AND METHODS: The disks were cast by two types of metal. Their surfaces were treated by sandblasting, metal conditioner, TiN coating and silicoating respectively. After surface treatment, the disks were veneered by composite resin (Tescera(TM), Bisco, USA) which is 5 mm in diameter and 3 mm in thickness. The specimens were stored in water at 25degrees C for 24 hours, and then evaluated for their shear bond strength by universal testing machine (STM-5(R), United Calibration, USA). These values were statistically analyzed. RESULTS: 1. All methods of surface treatment were used in this study satisfied the requirements of ISO 10477 which is the standard of polymer-based crown and bridge materials. 2. The metal conditioner treated group showed the highest value in shear bond strength of CP Ti, silicoated group, TiN coated group, sandblasted group, in following order. 3. The silicoated group showed the highest value in shear bond strength of Ti-6Al-4V alloy, metal conditioner treated group, sandblasted group, TiN coated group, in following order. CONCLUSION: Within the limitations of this study, all methods of surface treatment used in this study are clinically available.
Alloys
;
Calibration
;
Collodion
;
Crowns
;
Tin
;
Titanium
;
Water
6.Hypoplasia of Left Vertebral Artery with Intimal Fibromuscular Dysplasia in a Korean Woman.
Chang Lim HYUN ; Hyun Sik PARK ; Hyun Jo SHIN ; Sang Pil YOON
Journal of Korean Medical Science 2012;27(7):811-813
We found a case of hypoplasia of vertebral artery with fibromuscular dysplasia in an 82-yr-old Korean female cadaver during a routine dissection course. In the present case, intracranial hypoplasia in left vertebral artery and bilateral origin of posterior inferior cerebellar artery at the vertebrobasilar junction were recognized. Histopathologically, left vertebral artery showed intimal type of fibromuscular dysplasia both in its extracranial and intracranial courses. These results indicate that the association of fibromuscular dysplasia and hypoplasia does exist in the vertebral artery, although the etiologies are not verified yet.
Aged, 80 and over
;
Female
;
Fibromuscular Dysplasia/*pathology
;
Heart Ventricles/abnormalities/*pathology
;
Humans
;
Republic of Korea
;
Vertebral Artery/*pathology
7.The Clinical Analysis of 100 cases of Coronary artery Bypass Grafting with the Right Gastroepiploic artery.
Hyun SONG ; Han Jung LIM ; Hyun Woo LEE ; Jong Pil JUNG ; Je Kyoun SHIN ; Jong Ook KIM ; Jong Bin PARK ; Jae Won LEE ; Meong Gun SONG
The Korean Journal of Thoracic and Cardiovascular Surgery 2000;33(8):638-642
BACKGROUND: In an effort t enhance long term patency of coronary bypass grafts, utilization of arterial conduits have been on an icrease. With the same objective, we have been using the right gastroepiploic artery (RGEA) in coronary artery bypass procedures since 1998. The current paper has been undertaken with the aim of assessing the apropriateness, problems, and short term results of using the RGEA as an arterial graft conduit by studying the postoperative clinical results of 100 patients than received coronary artery bypass grafting (CARG) with this artery. MATERIAL AND METHOD: Between May of 1998 and May of 1999, an analysis of the mortality, postoperative myocardial infarction, and the need for IABP insertion as a result of low cardiac output were made between 100 consecutive patients undergoing CABG with the RGEA. There was one postoperative death due to cerebral infarction. Postoperative complications/morbidity comprised myocardial infarction in 2, cerebral infarct in 3, reoperation due to bleeding in 1, mediastinitis in 1, and low cardiac output syndrome necessitating IABP in 3 patients. Complicatons related to harvesting of the arterial grafts were not experienced in any of the patients. CONCLUSION: The results of the current data show that utilization of the RGEA in CABG is not associated with increased mortality/morbidity and demonstrates satisfactory short term results suggesting the usefulnessof this conduit as an arterial graft.
Arteries
;
Cardiac Output, Low
;
Cerebral Infarction
;
Coronary Artery Bypass*
;
Coronary Vessels*
;
Gastroepiploic Artery*
;
Hemorrhage
;
Humans
;
Mediastinitis
;
Mortality
;
Myocardial Infarction
;
Reoperation
;
Transplants
8.Fabrication of additive manufacturing interim denture and comparison with conventional interim denture: A case report
Hyun Ah KIM ; Hyun Pil LIM ; Hyeon KANG ; Hongso YANG ; Sang Won PARK ; Kwi Dug YUN
The Journal of Korean Academy of Prosthodontics 2019;57(4):483-489
With development of digital dentistry, the 3-dimensional (3D) manufacturing industry using computer-aided design and computer-aided manufacturing (CAD/CAM) has grown dramatically in recent years. Denture fabrication using digital method is also increasing due to the recent development of digital technology in dentistry. The 3D manufacturing process can be categorized into 2 types: subtractive manufacturing (SM) and additive manufacturing (AM). SM, such as milling is based on cutting away from a solid block of materal. AM, such as 3D printing, is based on adding the material layer by layer. AM enables the fabrication of complex structures that are difficult to mill. In this case, additive manufacturing method was applied to the fabrication of the resin-based complete denture to a 80 year-old patient. During the follow-up periods, the denture using digital method has provided satisfactory results esthetically and functionally.
Computer-Aided Design
;
Dentistry
;
Denture, Complete
;
Dentures
;
Follow-Up Studies
;
Humans
;
Methods
;
Printing, Three-Dimensional
9.Wettability and drug delivery of functionally graded nano-micro porous titanium surface.
Kwi Dug YUN ; Mong Sook VANG ; Hong So YANG ; Sang Won PARK ; Ha Ok PARK ; Hyun Pil LIM
The Journal of Korean Academy of Prosthodontics 2008;46(3):307-319
STATEMENT OF PROBLEM: It is known that an anodic oxidation technique, one of the methods for the implant surface treatment, remarkably increased surface area, enhanced wettability and accelerated the initial bone healing. Purpose: This study was performed to evaluate the wettability of anodized titanium surface which has a nanotubular structure, to assess osseointegration after the placement of implant with nano-size tubes on tibia of rats and to analyze quantitatively transferable rhBMP-2 on each surface. MATERIAL AND METHOD: Four different kinds of surface-treated titanium discs (polished (machined surface) group, micro (blasting surface) group, nano (anodizedmachined surface) group, and nano-micro (anodized-blasting surface) group) were fabricated (n=10). Three different media were chosen to measure the surface contact angles; distilled water, plasma and rhBMP-2 solution. After a single drop (0.025 ml) of solution, the picture was taken with the image camera, and contact angle was measured by using image analysis system. For the test of osseointegration, 2 kinds of anodized surface (anodized-machined surface, anodized-blasting surface) implants having 2.0 mm in diameter and 5.0 mm in length inserted into the tibia of Wistar rats. After 3 weeks, tibia were harvested and the specimens were stained with hematoxylin and eosin for histological analysis. To test the possibility of drug delivery, after soaking sample groups in the concentration of 250 ng/ml of rhBMP-2 for 48 hours, the excess solution of rhBMP-2 were removed. After that, they were lyophilized for 24 hours, and then the rhBMP-2 on the surface of titanium was resolved for 72 hours in PBS. All the extracted solution was analyzed by ELISA. One-way analysis of variance (ANOVA) was performed on the data. RESULTS: The wettability is improved by anodic oxidation. The best wettability was shown on the nano-micro group, and it was followed by nano group, micro group, and polished group. In the histological findings, all implants showed good healing and the new bone formation were observed along the implant surface. After 3 days, nano-micro group delivered the most amount of rhBMP-2, followed by nano group, micro group, and polished group. CONCLUSION: It indicated that anodic oxidation on blasting surface produce functionally graded nano-micro porous structure and enhance hydrophilicity of the surface and osseointegration. The findings suggest that the nano-micro porous structure could be a useful carrier of osteogenic molecules like rhBMP-2.
Animals
;
Durapatite
;
Enzyme-Linked Immunosorbent Assay
;
Eosine Yellowish-(YS)
;
Hematoxylin
;
Hydrophobic and Hydrophilic Interactions
;
Osseointegration
;
Osteogenesis
;
Plasma
;
Rats
;
Rats, Wistar
;
Tibia
;
Titanium
;
Water
;
Wettability
10.Sintering behavior and mechanical properties of zirconia compacts fabricated by uniaxial press forming.
Gye Jeong OH ; Kwi Dug YUN ; Kwang Min LEE ; Hyun Pil LIM ; Sang Won PARK
The Journal of Advanced Prosthodontics 2010;2(3):81-87
PURPOSE: The purpose of this study was to compare the linear sintering behavior of presintered zirconia blocks of various densities. The mechanical properties of the resulting sintered zirconia blocks were then analyzed. MATERIAL AND METHODS: Three experimental groups of dental zirconia blocks, with a different presintering density each, were designed in the present study. Kavo Everest(R) ZS blanks (Kavo, Biberach, Germany) were used as a control group. The experimental group blocks were fabricated from commercial yttria-stabilized tetragonal zirconia powder (KZ-3YF (SD) Type A, KCM. Corporation, Nagoya, Japan). The biaxial flexural strengths, microhardnesses, and microstructures of the sintered blocks were then investigated. The linear sintering shrinkages of blocks were calculated and compared. RESULTS: Despite their different presintered densities, the sintered blocks of the control and experimental groups showed similar mechanical properties. However, the sintered block had different linear sintering shrinkage rate depending on the density of the presintered block. As the density of the presintered block increased, the linear sintering shrinkage decreased. In the experimental blocks, the three sectioned pieces of each block showed the different linear shrinkage depending on the area. The tops of the experimental blocks showed the lowest linear sintering shrinkage, whereas the bottoms of the experimental blocks showed the highest linear sintering shrinkage. CONCLUSION: Within the limitations of this study, the density difference of the presintered zirconia block did not affect the mechanical properties of the sintered zirconia block, but affected the linear sintering shrinkage of the zirconia block.
Cyclic N-Oxides
;
Zirconium