1.Unilateral pulsatile tinnitus: A case report.
Hong Chul KIM ; Tae Hyun YOON ; Ki Cheon LEE ; Seong Hak KIM
Korean Journal of Otolaryngology - Head and Neck Surgery 1993;36(2):342-346
No abstract available.
Tinnitus*
2.The Comparison of The Matrix Perimetry and Humphrey Standard Perimetry in Various Patients Group.
Hyun Chul CHEON ; Woo Jin JEUNG ; Sae Heun RHO
Journal of the Korean Ophthalmological Society 2007;48(5):678-685
PURPOSE: To study the correlation between the Humphrey standard automated perimetry (SAP) and the Humphrey Matrix Frequency Doubling Technology (FDT) perimetry and diagnostic usefulness of the Humphrey Matrix FDT perimetry. METHODS: This study included 170 eyes of 170 patients. The 170 eyes were classified into 50 normal eyes, 20 ocular hypertensive eyes, 50 glaucoma-suspect eyes and 50 glaucomatous eyes. All subjects were examined with the Humphrey Matrix perimetry and the Humphrey standard automated perimetry. We studied the correlations between mean deviation (MD) and pattern standard deviation(PSD) of the Humphrey SAP and those of the Humphrey Matrix perimetry, respectively, in each of the classified group. RESULTS: Overall, MD and PSD of the Humphrey SAP were significantly correlated with MD and PSD of the Humphrey Matrix perimetry, respectively. However, MD and PSD of the Humphrey Matrix perimetry were not showed a significant correlation in normal subjects (P>0.05). CONCLUSIONS: In this study, there were significant correlations between the MD and PSD of the SAP and those of the Humphrey Matrix perimetry in glaucoma, glaucoma-suspect and ocular hypertension. These finding suggests the Humphrey Matrix perimetry has performance characteristics similar to SAP and diagnostic value.
Glaucoma
;
Humans
;
Ocular Hypertension
;
Visual Field Tests*
3.A Case of Crossed Renal Ectopia with Fusion.
Sang Chul HAN ; Jun CHEON ; Hyun Moo LEE ; Bang Whan JUN
Korean Journal of Urology 1990;31(6):937-939
When an ectopic kidney is located on the opposite site from its ureteral insertion into the bladder, the condition is known as crossed ectopia. Ninety per cent of crossed ectopic kidneys are fused to the ipsilateral kidney. Herein we report a case of crossed renal ectopia with fusion in a 20 year old male.
Humans
;
Kidney
;
Male
;
Ureter
;
Urinary Bladder
;
Young Adult
4.A Case of Brain Metastasis from Prostatic Adenocarcinoma Which Showed Remarkable Effect in Combined Chemotherapy.
Heon Joong KANG ; Jae Cheon AHN ; Seong CHOI ; Jong Chul KIM ; Hyun Ryul RHEW
Korean Journal of Urology 1994;35(9):1020-1022
The brain metastasis of prostatic carcinoma is rare and is distinguished by its poor prognosis in cases which are not surgically resectable. Herein we described a 72 year old male with brain metastasis from prostatic carcinoma, which regressed with chemotherapy. Pathological examination of a transrectal needle biopsy disclosed moderatedly differentiated adenocarcinoma of the prostate. Magnetic resonance imaging of brain demonstrated a brain tumor at the occipital lobe suspected to be a metastasis of prostatic carcinoma. The tumor could not be detected on the brain MRI after 3 months of chemotherapy.
Adenocarcinoma*
;
Aged
;
Biopsy, Needle
;
Brain Neoplasms
;
Brain*
;
Drug Therapy*
;
Humans
;
Magnetic Resonance Imaging
;
Male
;
Neoplasm Metastasis*
;
Occipital Lobe
;
Prognosis
;
Prostate
6.An Experimental Study of Silastic Cuff Wrapping Around the Severed Peripheral Nerve
Hong Chul LIM ; Woo Nam MOON ; Jae Young CHEON ; Jay Suck CHANG ; Seok Hyun LEE ; In Young SUNG
The Journal of the Korean Orthopaedic Association 1987;22(1):14-22
The authors conducted an in-Vivo experimental study using sciatic nerve of 200-300 grammed rats to verify clinical applicability of Silicone cuffing method, by which scar adhesion of repaired nerve in crushed limb is assumed hopefully to be reduced. The following observations were obtainable. 1. Nerve conduction velocity was noted faster in Silicone cuff group than in control group significantly after 6 weeks postoperatively. 2. Adhesion of repaired nerve with surrounding scar tissue was far less present in Silicone cuff group than in control group when observed grossly. 3. The amount of scar formation and axonal degeneration were noted reduced remarkably in Silicone cuff group than in control group after 3 weeks postoperatively. 4. The intraneural vascularity was noted reduced either in Silicone cuff group and in control group, but definitely less reduced in the former than in the latter. Clinical relevance: Above results may be taken as an experimental basis supporting clinical applicability of Silicone cuff wrapping method for neurorraphy in crushed limb.
Animals
;
Axons
;
Cicatrix
;
Extremities
;
Methods
;
Neural Conduction
;
Peripheral Nerves
;
Rats
;
Sciatic Nerve
;
Silicon
;
Silicones
7.The Weaning Method of inhaled Nitric Oxide.
Hyun Woo LEE ; Jae Woong LEE ; Sung Yeul HYUN ; Ha Chang LEE ; Chul Hyun PARK ; Kook Yang PARK ; Hyeon Su YOO ; Kyung Cheon LEE ; Young Jin JANG
Journal of the Korean Pediatric Society 2001;44(4):413-417
PURPOSE: inhaled nitric oxide(iNO) is an excellent method for the postoperative pulmonary hypertension in congenital heart disease. But more detailed care is needed because of the development of rebound pulmonary hypertension after NO Withdrawal. We performed this study in order to discontinue the iNO successfully by way of presenting the adequate weaning and supplying methods. METHODS: Between January, 1998 and August, 1999 we sudied 10 patients who had rebound pulmonary hypertension(RPH) after iNO withdrawal. We completed the iNO in these patween the first the second trial of the weaning process. We tried to discover the differences between the first and second weaning process. We measured NO concentration at the start and just before NO withdrawal and during the period of weaning process. Moreover, to identify the iNO effects during the weaning of the iNO, we counted the degree of the change of PaO2/FiO2and mean PAP/SAP beween initial and at half of the initial NO concentration. RESULTS: Second weaning had a longer duration weaning process(11+/-0 cersus 5+/- hours, P<0.05), lower NO concentration just before NO withdrawal(2+/-.6 versus 4+/-ppm, P<0.05). In the change of the mean PAP/SAP and PaO2/FiO2as iNO was weaning from the initial iNO concentration to a half of the initial iNO concentration, the degree of increase in mean PAP/SAP(0.026+/-.07 versus 0.054+/-.07, P<0.05) and the degree of decrease in PaO2/FiO2(49+/-4 versus 65+/-2, P<0.05) were smaller in the second in the second weaning process than the first weaning process. CONCLUSION: A successful weaning of iNO can be performed with a low iNO concentration at the start and just before withdrawal and with the long duration iNO weaning process. Moreover, We speculate that the degree of change in the mean PAP/SAP and PaO2/FiO2at the half of the iNO weaning process are an indicator for the development of RPH.
Heart Defects, Congenital
;
Humans
;
Hypertension, Pulmonary
;
Nitric Oxide*
;
Weaning*
8.Comparison of Wound Healing Between Conventional Tie-over Dressing and Silicone Sheeting after Skin Grafting.
Hyun Chul PARK ; Hyun Sik PARK ; Sang Cheon AHN ; Sang Hyun CHO ; Sang Soo KIM ; Jin CHANG
Journal of the Korean Microsurgical Society 2011;20(1):26-31
PURPOSE: We compared wound healing between the conventional tie-over dressing and silicone sheeting after skin grafting in patients with skin defects. MATERIALS AND METHODS: Of a total of 30 cases of skin defects, 15 underwent conventional tie-over dressing and the remaining 15 underwent silicone sheeting skin grafting, we compared hematoma formation and infection status between the 2 techniques 1 and 2 weeks after operation. RESULTS: Hematoma was not observed in all cases. The wound infection rate decreased in silicone group. CONCLUSIONS: Silicone sheeting skin graft may be helpful in reducing wound infection.
Bandages
;
Hematoma
;
Humans
;
Silicones
;
Skin
;
Skin Transplantation
;
Transplants
;
Wound Healing
;
Wound Infection
9.Safety and efficacy of transcutaneous bone conduction implant surgery for hearing improvement in microtia patients with bilateral hearing impairment
Jeong Hyun CHEON ; Hyung Chul LEE ; Gi Jung IM ; Jung Youl PARK ; Chul PARK
Archives of Plastic Surgery 2019;46(6):525-534
BACKGROUND:
In microtia patients with bilateral hearing impairment, hearing improvement is crucial for language development and performance. External auditory canal reconstruction (EACR) has been performed to improve hearing, but often results in complications. We performed transcutaneous bone conduction implant (TBCI) surgery in these patients. This study aimed to evaluate the safety and efficacy of TBCI surgery.
METHODS:
A retrospective review was performed of five patients who underwent auricular reconstruction and TBCI surgery and 12 patients who underwent EACR between March 2007 and August 2018. Hearing improvement was measured based on the air-bone gap values using pure-tone audiometry over a 6-week postoperative period. We reviewed other studies on hearing improvement using EACR and compared the findings with our results. The surgical techniques for TBCI were reviewed through case analyses.
RESULTS:
Postoperative hearing outcomes showed a significant improvement, with a mean gain of 34.1 dB in the TBCI cohort and 14.1 dB in the EACR cohort. Both gains were statistically significant; however, the TBCI cohort showed much larger gains. Only three of the 12 patients who underwent EACR achieved hearing gains of more than 20 dB, which is consistent with previous studies. All patients who underwent TBCI surgery demonstrated hearing gains of more than 20 dB and experienced no device-related complications.
CONCLUSIONS
TBCI is a safe and effective method of promoting hearing gains in microtia patients with bilateral hearing impairment. TBCI surgery provided better hearing outcomes than EACR and could be performed along with various auricular reconstruction techniques using virgin mastoid skin.
10.Modified Extension Block Technique Using Conjoined Kirschner Wires for Bony Mallet Fingers.
Hyun Chul PARK ; Hyun Sik PARK ; Sang Cheon AHN ; Sang Soo KIM ; Jin CHANG
Journal of the Korean Society for Surgery of the Hand 2010;15(4):164-168
PURPOSE: To analyze the clinical results of the modified extension block fixation method using conjoined K-wires for bony mallet fractures. MATERIALS AND METHODS: From March 2006 to March 2009, we performed conjoined K-wire fixation as a modification of extension block technique in 9 patients with a bony mallet finger. After the average follow-up of 4.8 months, range of motion, pain, nail deformity, and bony union were evaluated. RESULTS: The average range of motion was 3.3degrees (range, 0-20degrees)of extension lag and 76.7degrees (range, 45-90degrees) of flexion. Bony union was obtained in all patients. No nail deformity was observed. One patient complained of distal interphalangeal joint pain. CONCLUSION: The extension block fixation method using conjoined K-wires can be an acceptable treatment option which provides stable fixation in bony mallet fractures.
Bone Wires
;
Congenital Abnormalities
;
Fingers
;
Follow-Up Studies
;
Humans
;
Joints
;
Nails
;
Range of Motion, Articular