1.Stereotactic Target point Verification in Actual Treatment Position of Radiosurgery.
Journal of the Korean Society for Therapeutic Radiology 1995;13(4):403-408
PURPOSE: Authors tried to enhance the safety and accuracy of radiosurgery by verifying stereotctic target point in actual treatment position prior to irradiation. MATERIALS AND METHODS: Before the actual treatment, several sections of anthropomorphic head phantom were used to create a condition of unknown coordinated of the target point. A film was sandwitched between the phantom sections and punctured by sharp needle tip. The tip of the needle represented the target point. The head phantom was fixed to the stereotactic ring and CT scan was done with CT localizer attached to the ring. After the CT scanning, the stereotactic coordinates of the target point were determined. The head phantom was secured to accelerator's treatment couch and the movement of laser isocenter to the stereotactic coordinates determined by CT scanning was performed using target positioner. Accelerator's anteroposterior and lateral portal films were taken using angiographic localizers. The stereotactic coordinates determined by analysis of portal films were compared with the stereotactic coordinates previously determined by CT scanning. Following the correction of discrepancy, the head phantom was irradiated using a stereotactic thechnique of several arcs. After the irradiation, the film which was sandwitched between the phantom sections was developed and the degree of coincidence between the center of the radiation distribution with the target point represented by the hole in the film was measured. In the treatment of actual patients, the way of determining the stereotactic coordinates with CT localizers and angiographic localizers between two sets of coordinates, we proceeded to the irradiation of the actual patient. RESULTS: In the phantom study, the agreement between the center of the radiation distribution and the localized target point was very good. By measuring optical density profiles of the sandwitched film along axes that intersected the target point, authors could confirm the discrepancy was 0.3mm. In the treatment of an actual patient, the discrepancy between the stereotactic coordinates with CT localizers and angiographic localizers was 0.6mm. CONCLUSION: By verifying stereotactic target point in actual treatment position prio to irradiation, the accuracy and safety of streotactic radiosurgery procedure were established.
Head
;
Humans
;
Needles
;
Radiosurgery*
;
Tomography, X-Ray Computed
2.Stereotactic Target point Verification in Actual Treatment Position of Radiosurgery.
Journal of the Korean Society for Therapeutic Radiology 1995;13(4):403-408
PURPOSE: Authors tried to enhance the safety and accuracy of radiosurgery by verifying stereotctic target point in actual treatment position prior to irradiation. MATERIALS AND METHODS: Before the actual treatment, several sections of anthropomorphic head phantom were used to create a condition of unknown coordinated of the target point. A film was sandwitched between the phantom sections and punctured by sharp needle tip. The tip of the needle represented the target point. The head phantom was fixed to the stereotactic ring and CT scan was done with CT localizer attached to the ring. After the CT scanning, the stereotactic coordinates of the target point were determined. The head phantom was secured to accelerator's treatment couch and the movement of laser isocenter to the stereotactic coordinates determined by CT scanning was performed using target positioner. Accelerator's anteroposterior and lateral portal films were taken using angiographic localizers. The stereotactic coordinates determined by analysis of portal films were compared with the stereotactic coordinates previously determined by CT scanning. Following the correction of discrepancy, the head phantom was irradiated using a stereotactic thechnique of several arcs. After the irradiation, the film which was sandwitched between the phantom sections was developed and the degree of coincidence between the center of the radiation distribution with the target point represented by the hole in the film was measured. In the treatment of actual patients, the way of determining the stereotactic coordinates with CT localizers and angiographic localizers between two sets of coordinates, we proceeded to the irradiation of the actual patient. RESULTS: In the phantom study, the agreement between the center of the radiation distribution and the localized target point was very good. By measuring optical density profiles of the sandwitched film along axes that intersected the target point, authors could confirm the discrepancy was 0.3mm. In the treatment of an actual patient, the discrepancy between the stereotactic coordinates with CT localizers and angiographic localizers was 0.6mm. CONCLUSION: By verifying stereotactic target point in actual treatment position prio to irradiation, the accuracy and safety of streotactic radiosurgery procedure were established.
Head
;
Humans
;
Needles
;
Radiosurgery*
;
Tomography, X-Ray Computed
3.Experience of Meningovascular Syphilis in Human Immunodeficiency Virus Infected Patient.
Jung Pyo LEE ; Sun Ho KOO ; So Young JIN ; Tae Hyong KIM
Journal of Korean Neurosurgical Society 2009;46(4):413-416
Since the start of the antibiotic era, syphilis has become rare. However, in recent times, it has tended to be prevalent concomitantly with human immunodeficiency virus (HIV) infection and coinfection in North America and Europe. Now, such cases are expected to increase in elsewhere including Korea. A 40-year-old male patient visited hospital complaining of a headache for about one month. Brain computed tomography and magnetic resonance imaging, showed leptomeninged enhancing mass with edema an right porisylvian region, which was suspected to be glioma. Patient underwent a blood test and was diagnosed with syphilis and acquired immune deficiency syndrome. Partial cortical and subcortical resection were performed after small craniotomy. The dura was thick, adhered to the brain cortex, and was accompanied by hyperemic change of the cortex. The pathologic diagnosis was meningovascular syphilis (MS) in HIV infection. After the operation, the patient was treated with aqueous penicillin G. Thereafter, he had no neurological deficit except intermittent headache. At first, this case was suspected to be glioma, but it was eventually diagnosed as MS in HIV coinfection. At this point the case was judged to be worth reporting.
Acquired Immunodeficiency Syndrome
;
Adult
;
Brain
;
Coinfection
;
Craniotomy
;
Edema
;
Europe
;
Glioma
;
Headache
;
Hematologic Tests
;
HIV
;
HIV Infections
;
Humans
;
Korea
;
Magnetic Resonance Imaging
;
Male
;
Neurosyphilis
;
North America
;
Penicillin G
;
Syphilis
4.Development of TEM Head-size Resonator for 3T MRI Head Coil.
Seung Hoon HA ; Bo Young CHOE ; Yong Sik KIM ; Sung Eun KIM ; Tae Suk SUH ; Hyong Koo LEE ; Kyung Sub SHINN ; Heung Kyu LEE
Journal of the Korean Society of Magnetic Resonance in Medicine 1999;3(3):232-238
PURPOSE: To apply a distributed circuit theory, to develop a head-size transverse electromagnetic(TEM) resonator coil for a home-built 3T whole-body MRI system and to report an efficiency of the coil. MATERIALS AND METHODS: The dimension of TEM resonator with 16 cavity element, the diameter of copper rod was 0.63cm and its length was 13.75cm. As raw materials, the purity of copper rod was 98% and the dielectric constant of teflon was 2.08. RESULTS: The TEM head-size resonator with 16cavity elements exhibiting 9-mode resonances was robust to the surrounding influences owing to the self-shielding structure. The isolation of quadrature with a human brain was 364 and the ratio of Q(unloaded/Q(loaded) was 2.9. CONCLUSION: It was successfully demonstrated that the TEM head-size resonator with high Q factor can provide high quality MR images at 3T MRI system. Also, the TEM resonator coil has an advantage for a fine tune with length adjustment of each cavity elements. Thus, it is expected that the TEM resonator at 3T, even higher field could be used in the clinical and research studies in near future.
Brain
;
Copper
;
Head*
;
Humans
;
Magnetic Resonance Imaging*
;
Polytetrafluoroethylene
5.Cytomegalovirus Infectious Mononucleosis in a Patient with a Gastric Ulcer.
Se Yoon PARK ; Eun Jung LEE ; Tae Hee LEE ; So My KOO ; Jin Nyoung KIM ; Min Huok JEON ; Eun Ju CHOO ; Tae Hyong KIM
Korean Journal of Gastrointestinal Endoscopy 2011;42(6):392-396
Cytomegalovirus (CMV) is a prevalent pathogen, with 98~100% of Korean adults showing prior exposure by serology. A primary infection, such as CMV infectious mononucleosis, is very rare. CMV infectious mononucleosis often presents an initial diagnostic problem. Patients are often hospitalized with a wide variety of clinical diagnoses including fever of unknown origin without pharyngitis and lymphadenopathy. CMV gastrointestinal infections are rare in previously immunocompetent individuals. The most common sites involved are the colon and rectum, although lesions of the stomach have also been described. It is unusual to see CMV infectious mononucleosis and CMV gastrointestinal infection in the same patient. Our patient received symptomatic treatment and fully recovered. We present a case of CMV infectious mononucleosis with gastric ulcers in a previously healthy adult.
Adult
;
Colon
;
Cytomegalovirus
;
Fever of Unknown Origin
;
Humans
;
Infectious Mononucleosis
;
Lymphatic Diseases
;
Pharyngitis
;
Rectum
;
Stomach
;
Stomach Ulcer
6.Characteristics of Device-Associated Cerebrospinal Fluid Infection in Adults.
So My KOO ; Eun Jung LEE ; Se Yoon PARK ; Shi Nae YU ; Min Young LEE ; Tae Hyong KIM ; Eun Ju CHOO ; Min Huok JEON
Soonchunhyang Medical Science 2013;19(2):51-55
OBJECTIVE: Device-associated infections in the central nervous system are serious complications of procedures involving indwelling devices among neurosurgical patients. In this study, the clinical characteristics and outcome of microbiologically confirmed device-associated cerebrospinal fluid (CSF) infection were evaluated. METHODS: We performed a retrospective analysis of adult patients found to have a positive CSF culture result during a hospital admission between 1 January 2005 through 2 October 2010 in Soonchunhyang University Hospital. RESULTS: During the study period, all episodes (n=161 CSF specimens, 87 patients) involving a culture-positive CSF were enrolled. Thirty-two episodes of device-associated CSF infection were included in the analysis among the study group. Most device-associated infections were ventriculo-peritoneal shunt infections (14/32, 44%). Fever (>38degrees C) was present in 17 episodes (53%). Overall, the most common microorganism was coagulase-negative staphylococcus (7/32 [22%]). Gram-negative rods (Pseudomonas aeruginosa 6/32 [19%], Acinetobacter baumannii/haemolyticus 5/32 [16%]) were identified in culture in 16/32 (50%). Device was removed for the control of device-associated infection in 30/32 (94%). Cure rate was 69% (22/32). All patients with treatment failure (10/32, 34%) expired. CONCLUSION: It is difficult to diagnosis device-associated CSF infections early since those are frequently presented with nonspecific clinical signs and symptoms. In our study, gram-negative infections accounted for 50% of cases and the empiric antibiotics initially chosen were found to not be effective against the final identified pathogen in many cases. Device-associated CSF infections should be strongly considered a serious risk factor associated with CSF infections, and prompt initiation of broad coverage antibiotics should be started after appropriate assessment.
Acinetobacter
;
Adult*
;
Anti-Bacterial Agents
;
Central Nervous System
;
Cerebral Ventriculitis
;
Cerebrospinal Fluid*
;
Diagnosis
;
Fever
;
Humans
;
Meningitis
;
Retrospective Studies
;
Risk Factors
;
Staphylococcus
;
Treatment Failure
;
Ventriculoperitoneal Shunt
7.Transmission Dose Estimation Algorithm for Irregularly Shaped Radiation Field.
Hyong Geun YUN ; Eui Kyu CHIE ; Soon Nyung HUH ; Hyoung Koo LEE ; Hong Gyun WU ; Kyo Chul SHIN ; Siyong KIM ; Sung Whan HA
The Journal of the Korean Society for Therapeutic Radiology and Oncology 2002;20(3):274-282
PURPOSE: Measurement of transmission dose is useful for in vivo dosimetry. In this study, the algorithm for estimating the transmission dose for open radiation fields was modified for application to partially blocked radiation fields. MATERIALS AND METHODS: The beam data was measured with a flat solid phantom with various blocked fields. A new correction algorithm for partially blocked radiation field was developed from the measured data. This algorithm was tested in some settings simulating clinical treatment with an irregular field shape. RESULTS: The correction algorithm for the beam block could accurately reflect the effect of the beam block, with an error within +/-1.0%, with both square fields and irregularly shaped fields. CONCLUSION: This algorithm can accurately estimate the transmission dose in most radiation treatment settings, including irregularly shaped field.
8.Transmission Dose Estimation Algorithm for Tissue Deficit.
Hyong Geun YUN ; Eui Kyu CHIE ; Soon Nyung HUH ; Hyoung Koo LEE ; Hong Gyun WOO ; Kyo Chul SHIN ; Sung Whan HA
The Journal of the Korean Society for Therapeutic Radiology and Oncology 2002;20(2):186-192
PURPOSE: Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. MATERIALS AND METHODS: The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. RESULTS: The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within +-1.0% in most situations and within +-3.0% in experimental settings with irregular contours mimicking breast cancer treatment set-up. CONCLUSION: Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.
Breast Neoplasms
;
Humans
9.Combined Effects of Gamma-irradiation and Hyperthermia on the Human Cell Lines for Various Temperatures and Time Sequences.
Kyung Hwan KOH ; Chul Koo CHO ; Woo Yoon PARK ; Seong Yul YOO ; Hyong Geun YUN ; Jae Won SHIM ; Mi Jung LEE
Journal of the Korean Society for Therapeutic Radiology 1993;11(1):51-58
We tried to establish the theoretical basis of clinical use of combined modality of hyperthermia and radiation therapy. For this purpose, we made an in vitro experiment in order to get the synergistic and/or additive effects on the cell killing of hyperthermia combined with radiation therapy by using the microwave-hyperthermia machine already installed at our department. In our experiment, we use two human cell lines: MKN-45(adenocarcinoma of stomach) and K-562(leukemia cell lines). In cases of combined treatments of hyperthermia and gamma-irradiation, the therapeutic effect was the highest in the simultaneous trial. Hyperthermia after gamma irradiation showed slightly higher therapeutic effect than that before irradiation without significant difference, but its effect was the same in the interval of 6 hours between hyperthermia and irradiation. The higher temperature and the longer treatment time were applied, the higher therapeutic effects were observed. We could observe the thermoresistance by time elapse at 43 degree C. When hyperthermia was done for 30 minutes at the same temperature, thermal enhancement ratio(TER) at D0.01(dose required surviving fraction of 0.01) were 2.5+/-0.08, 3.75+/-0.18, and 5.0+/-0.15 at 43 degree C, 44 degree C, and 45 degree C respectively in K-562 leukemia cell lines. Our experimental data showed that more cell killing effect can be obtained in the leukemia cell lines, although they usually are known to be radiosensitive, when treated with combined hyperthermia and radiation therapy. Furthermore, our data show that leukemia cell lines May have various intrinsic radiosensitivity, especially in vitro experiments. The magnitude of cell killing effect, however, will be less than that of MKN-45.
Cell Line*
;
Fever*
;
Homicide
;
Humans*
;
Leukemia
;
Radiation Tolerance
10.Total Plasma Exchange in a Patient with HD-MTX-induced Acute Renal Failure: A Case Report.
Hyong Ju KANG ; Hae Won HAN ; Myoung Cheol KIM ; Jin No PARK ; Dong Chan JIN ; Young Seon HONG ; Seung Koo RHEE ; Chun Choo KIM ; Kyung Shick LEE
Korean Journal of Hematology 2001;36(3):265-268
A 16-year-old male patient was diagnosed as chondroid osteosarcoma of the left humeral shaft. He showed normal serum creatinine level and no complications following the first course of high-dose methotrexate (HD-MTX) chemotherapy with a total dose of 12g/m2. After the 2nd HD-MTX chemotherapy with the same dosage as in the 1st course, plasma MTX levels soared up to 72micromol/L and serum creatinine level increased to 1.39mg/dL. We failed to lower the plasma MTX levels and to recover the renal function by high-dose leucovorin rescue and plasmapheresis. Plasma MTX level was successfully lowered after three consecutive total plasma exchanges and the withdrawal of aceclofenac which was suspected as an aggravating agent. No rebound in plasma MTX level was observed. We report that total plasma exchanges were effective in a patient with renal failure and delayed MTX excretion which occurred after HD-MTX chemotherapy.
Acute Kidney Injury*
;
Adolescent
;
Creatinine
;
Drug Therapy
;
Humans
;
Leucovorin
;
Male
;
Methotrexate
;
Osteosarcoma
;
Plasma Exchange*
;
Plasma*
;
Plasmapheresis
;
Renal Insufficiency