1.MR Features of Common Hepatic Duct Cholangiocarcinoma.
Mi Young KIM ; Yong Ho AUH ; Moon Gym LEE ; Dong Erk GOO ; Hyeon Kweun HA
Journal of the Korean Radiological Society 1994;30(4):687-691
PURPOSE: The role of MRI in the detection of cholangiocarcinoma of the common hepatic duct has rarely been described. This study was attempted to ascertain characteristic MR features of cholangiocarcinoma. MATERIALS AND METHODS: The T1(500/30, TRs/TEs) and T2 weighted(200/80, TRs/TEs) MR images were obtained from nine patients with cholangiocarcinoma of the common hepatic duct. The common hepatic lesions were detected in seven cases. MR features of cholangiocarcinoma were analysed according to the signal intensity and associated findings. RESULTS: The seven cases showed lower signal intensity than the surrounding normal liver parenchyma on T1 weighted image. On T2 weighted image, the tumor showed isosignal intensity and hyperintensity in four and three patients, respectively. T2 image also revealed diffusely increased signal intensity in some hepatic lobe or segment in four cases, and Intrahepatic periductal high signal intensity in one case. Other associated MR findings were intrahepatic metastasis, and intratumoral hemorrhage, each noted in a different case. CONCLUSION: T2 weighted Image appears to be effective in the detection of cholangiocarcinoma of the common hepatic duct and evaluation of its associated intrahepatic lesions.
Cholangiocarcinoma*
;
Hemorrhage
;
Hepatic Duct, Common*
;
Humans
;
Liver
;
Magnetic Resonance Imaging
;
Neoplasm Metastasis