2.Histologic assessment of the biological effects after speedy surgical orthodontics in a beagle animal model: a preliminary study.
Hong Suk KIM ; Young Jun LEE ; Young Guk PARK ; Kyu Rhim CHUNG ; Yoon Goo KANG ; HyeRan CHOO ; Seong Hun KIM
Korean Journal of Orthodontics 2011;41(5):361-370
OBJECTIVE: Speedy surgical orthodontics (SSO), an innovative orthodontic treatment, involves the application of orthopedic forces against temporary skeletal anchorage devices following perisegmental corticotomy to induce movement of specific dental segments. Herein, we report the biological effects of SSO on the teeth and periodontal structures. METHODS: Five beagle dogs were divided into 2 groups and their 6 maxillary incisors were retracted en masse by applying 500 g orthopedic force against a single palatal mini-plate. Retraction was performed without and with perisegmental corticotomy in groups I and II, respectively. All animals were killed on the 70th day, and their periodontal structures were processed for histologic analyses and scanning electronic microscopy (SEM). The linear distance between the third maxillary incisor and canine was used as a benchmark to quantify the retraction amount. RESULTS: Retraction was markedly faster and retraction amount greater in group II than in Group I. Surprisingly, Group II did not show any root resorption despite extensive retraction, while Group I showed prominent root surface irregularities. Similarly, SEM showed multiple resorption lacunae in Group I, but not in Group II. CONCLUSIONS: SSO is an effective and favorable orthodontic approach for major en masse retraction of the maxillary anterior teeth.
Animals
;
Dogs
;
Electronics
;
Electrons
;
Incisor
;
Microscopy
;
Orthodontics
;
Orthopedics
;
Root Resorption
;
Tooth
3.Evaluation of strategic uprighting of the mandibular molars using an orthodontic miniplate and a nickel-titanium reverse curve arch wire: Preliminary cephalometric study
Jae-Hyun PARK ; HyeRan CHOO ; Jin-Young CHOI ; Kyu-Rhim CHUNG ; Seong-Hun KIM
The Korean Journal of Orthodontics 2021;51(3):179-188
Objective:
To evaluate the overall treatment effects in terms of the amount of uprighting with changes in the sagittal and vertical positions of mandibular molars after applying an orthodontic miniplate with a nickel-titanium (NiTi) reverse curve arch wire (biocreative reverse curve [BRC] system).
Methods:
A total of 30 female patients (mean age, 25.99 ± 8.96 years) were treated with the BRC system (mean BRC time, 10.3 ± 4.07 months). An I-shaped C-tube miniplate (Jin Biomed) was placed at the labial aspect for the alveolar bone of the mandibular incisors. A 0.017 × 0.025-inch NiTi reverse curve arch wire was engaged at the C-tube mini-plate anteriorly and the first and second premolars and molars posteriorly in the mandibular arch. Pre- and post-BRC lateral cephalograms were analyzed. A paired t-test was used to analyze the treatment effects of BRC.
Results:
The mandibular second molars were intrusively uprighted successfully by the BRC system. Distal uprighting with a controlled vertical dimension was noted on the first molars when they remained engaged in the BRC and the distal ends of the arch wire were laid on the second molars. The mandibular first and second premolars showed a slight extrusion. The changes in the mandibular incisors were unremarkable, while the mandibular molar angulation improved significantly. The lower occlusal plane rotated counterclockwise (MP-LOP:1.13° ± 2.60°).
Conclusions
The BRC system can provide very effective molar uprighting without compromising the position of the mandibular anterior teeth.
4.Evaluation of strategic uprighting of the mandibular molars using an orthodontic miniplate and a nickel-titanium reverse curve arch wire: Preliminary cephalometric study
Jae-Hyun PARK ; HyeRan CHOO ; Jin-Young CHOI ; Kyu-Rhim CHUNG ; Seong-Hun KIM
The Korean Journal of Orthodontics 2021;51(3):179-188
Objective:
To evaluate the overall treatment effects in terms of the amount of uprighting with changes in the sagittal and vertical positions of mandibular molars after applying an orthodontic miniplate with a nickel-titanium (NiTi) reverse curve arch wire (biocreative reverse curve [BRC] system).
Methods:
A total of 30 female patients (mean age, 25.99 ± 8.96 years) were treated with the BRC system (mean BRC time, 10.3 ± 4.07 months). An I-shaped C-tube miniplate (Jin Biomed) was placed at the labial aspect for the alveolar bone of the mandibular incisors. A 0.017 × 0.025-inch NiTi reverse curve arch wire was engaged at the C-tube mini-plate anteriorly and the first and second premolars and molars posteriorly in the mandibular arch. Pre- and post-BRC lateral cephalograms were analyzed. A paired t-test was used to analyze the treatment effects of BRC.
Results:
The mandibular second molars were intrusively uprighted successfully by the BRC system. Distal uprighting with a controlled vertical dimension was noted on the first molars when they remained engaged in the BRC and the distal ends of the arch wire were laid on the second molars. The mandibular first and second premolars showed a slight extrusion. The changes in the mandibular incisors were unremarkable, while the mandibular molar angulation improved significantly. The lower occlusal plane rotated counterclockwise (MP-LOP:1.13° ± 2.60°).
Conclusions
The BRC system can provide very effective molar uprighting without compromising the position of the mandibular anterior teeth.
5.Biocreative Alveolar Molding Plate Treatment (BioAMP) for neonatal unilateral cleft lip and palate with excessively wide alveolar cleft and maxillary arch width
The Korean Journal of Orthodontics 2024;54(1):69-73
Since its inception in Europe in the 1950s, alveolar molding treatment for neonates with complete cleft lip and palate has undergone significant evolution in both design and application methodology, demonstrating effectiveness in normalizing the alveolar cleft and nasal shape. However, excessively wide alveolar clefts accompanied by disproportionately wide total maxillary arch pose significant challenges when utilizing conventional alveolar molding methods involving cyclical adding and grinding of acrylic on molding plates. The current report introduces a novel alveolar molding method named Biocreative Alveolar Molding Plate Treatment (BioAMP), which can normalize the maxillary alveolar cleft and arch shape without laborious conventional acrylic procedures. BioAMP sets the target arch form and provides unrestricted space for natural growth of the maxillary alveolar bones while systematically reducing the total maxillary arch width in precise increments. Two exemplary cases are presented as proofof-concept, showcasing the clinical innovation of BioAMP.
6.The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study.
Il Sik CHO ; HyeRan CHOO ; Seong Kyun KIM ; Yun Seob SHIN ; Duck Su KIM ; Seong Hun KIM ; Kyu Rhim CHUNG ; John C HUANG
Korean Journal of Orthodontics 2011;41(5):354-360
OBJECTIVE: To investigate the effects of different pilot-drilling methods on the biomechanical stability of self-tapping mini-implant systems at the time of placement in and removal from artificial bone blocks. METHODS: Two types of artificial bone blocks (2-mm and 4-mm, 102-pounds per cubic foot [102-PCF] polyurethane foam layered over 100-mm, 40-PCF polyurethane foam) were custom-fabricated. Eight mini-implants were placed using the conventional motor-driven pilot-drilling method and another 8 mini-implants were placed using a novel manual pilot-drilling method (using a manual drill) within each of the 2-mm and 4-mm layered blocks. The maximum torque values at insertion and removal of the mini-implants were measured, and the total energy was calculated. The data were statistically analyzed using linear regression analysis. RESULTS: The maximum insertion torque was similar regardless of block thickness or pilot-drilling method. Regardless of the pilot-drilling method, the maximum removal torque for the 4-mm block was statistically higher than that for the 2-mm block. For a given block, the total energy at both insertion and removal of the mini-implant for the manual pilot-drilling method were statistically higher than those for the motor-driven pilot-drilling method. Further, the total energies at removal for the 2-mm block was higher than that for the 4-mm block, but the energies at insertion were not influenced by the type of bone blocks. CONCLUSIONS: During the insertion and removal of mini-implants in artificial bone blocks, the effect of the manual pilot-drilling method on energy usage was similar to that of the conventional, motor-driven pilot-drilling method.
Foot
;
Linear Models
;
Polyurethanes
;
Torque
7.Root proximity of the anchoring miniscrews of orthodontic miniplates in the mandibular incisal area: Cone-beam computed tomographic analysis
Do-Min JEONG ; Song Hee OH ; HyeRan CHOO ; Yong-Suk CHOI ; Seong-Hun KIM ; Jin-Suk LEE ; Eui-Hwan HWANG
The Korean Journal of Orthodontics 2021;51(4):231-240
Objective:
This outcome analysis study evaluated the actual positions of the orthodontic miniplate and miniplate anchoring screws (MPASs) and the risk factors affecting adjacent anatomic structures after miniplate placement in the mandibular incisal area.
Methods:
Cone-beam computed tomographic images of 97 orthodontic miniplates and their 194 MPASs (diameter, 1.5 mm; length, 4 mm) in patients whose miniplates provided sufficient clinical stability for orthodontic treatment were retrospectively reviewed. For evaluating the actual positions of the miniplates and analyzing the risk factors, including the effects on adjacent roots, MPAS placement height (PH), placement depth (PD), plate angle (PA), mental fossa angle (MA), and root proximity were assessed using the paired t-test, analysis of variance, and generalized linear model and regression analyses.
Results:
The mean PDs of MPASs at positions 1 (P1) and 2 (P2) were 2.01 mm and 2.23 mm, respectively. PA was significantly higher in the Class III malocclusion group than in the other groups. PH was positively correlated with MA and PD at P1. Of the 97 MPASs at P1, 49 were in the no-root area and 48 in the dentulous area; moreover, 19 showed a degree of root contact (19.6%) without root perforation. All MPASs at P2 were in the no-root area.
Conclusions
Positioning the miniplate head approximately 1 mm lower than the mucogingival junction is highly likely to provide sufficient PH for the P1-MPASs to be placed in the no-root area.
8.Root proximity of the anchoring miniscrews of orthodontic miniplates in the mandibular incisal area: Cone-beam computed tomographic analysis
Do-Min JEONG ; Song Hee OH ; HyeRan CHOO ; Yong-Suk CHOI ; Seong-Hun KIM ; Jin-Suk LEE ; Eui-Hwan HWANG
The Korean Journal of Orthodontics 2021;51(4):231-240
Objective:
This outcome analysis study evaluated the actual positions of the orthodontic miniplate and miniplate anchoring screws (MPASs) and the risk factors affecting adjacent anatomic structures after miniplate placement in the mandibular incisal area.
Methods:
Cone-beam computed tomographic images of 97 orthodontic miniplates and their 194 MPASs (diameter, 1.5 mm; length, 4 mm) in patients whose miniplates provided sufficient clinical stability for orthodontic treatment were retrospectively reviewed. For evaluating the actual positions of the miniplates and analyzing the risk factors, including the effects on adjacent roots, MPAS placement height (PH), placement depth (PD), plate angle (PA), mental fossa angle (MA), and root proximity were assessed using the paired t-test, analysis of variance, and generalized linear model and regression analyses.
Results:
The mean PDs of MPASs at positions 1 (P1) and 2 (P2) were 2.01 mm and 2.23 mm, respectively. PA was significantly higher in the Class III malocclusion group than in the other groups. PH was positively correlated with MA and PD at P1. Of the 97 MPASs at P1, 49 were in the no-root area and 48 in the dentulous area; moreover, 19 showed a degree of root contact (19.6%) without root perforation. All MPASs at P2 were in the no-root area.
Conclusions
Positioning the miniplate head approximately 1 mm lower than the mucogingival junction is highly likely to provide sufficient PH for the P1-MPASs to be placed in the no-root area.
9.Split orthodontic airway plate: An innovation to the utilization method of conventional orthodontic airway plate for neonates with Robin sequence
HyeRan CHOO ; Seong-Hun KIM ; Hyo-Won AHN ; Christian F. POETS ; Kyu-Rhim CHUNG
The Korean Journal of Orthodontics 2022;52(4):308-312
Since the emergence of neonatal infant orthodontics for treatments of cleft lip and palate with or without Robin sequence (RS) in Europe in the 1950s, advancements in design and scope of its application have been remarkable. As the first institution to adopt orthodontic airway plate (OAP) treatment in the United States in 2019, we saw a need for innovation of the original design to streamline the most labor-intensive and time-consuming aspects of OAP utilization. A solution is introduced using a systematic split expansion mechanism to re-size the OAP periodically to accommodate the neonate’s maxillary growth. To date, seven RS patients have received this modified treatment protocol at our institution. Each patient completed full treatment using only one OAP. This innovative utilization method is aptly named the split orthodontic airway plate (S-OAP). Details of the S-OAP and its modifications from conventional OAP are reported.