10.Determination of1-bromopropane in the workplace air by GC-FID.
Chun-hua WU ; Fu XU ; Xiu-li CHANG ; Xin XU ; Jian-cheng LIU ; Zhi-jun ZHOU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2013;31(6):467-469
OBJECTIVETo establish a method for determination 1-bromopropane (1-BP) in workplace air by gas chromatography-flame ionization detector (GC-FID).
METHOD1-bromopropane in workplace air was collected with activated charcoal tube, then desorbed by carbon disulfide and determined by GC-FID. 1-bromopropane was quantitatively measured using retention time and peak area.
RESULTSLinear regression formula was Y = 3353.4x-10064 in a range of 2.50 ∼ 500.00 µg/ml with regression coefficient R = 0.9998. Detection limit was 0.25 µg/ml and the lowest detection concentration of 1-brmopropane in air was 0.14 mg/m(3) (at air volume 1.8L). The mean recoveries of 1-BP were between 96.8% and 102.6%, and relative standard deviation of inter and intra-assay was less than 10%. The average desorption efficiencies were between 93.2% and 104.4%. The samples in activated charcoal tube could be stably stored for 5 days at room temperature.
CONCLUSIONThe method could be feasible to determine 1-bromopropane in workplace air.
Air ; analysis ; Air Pollutants, Occupational ; analysis ; Chromatography, Gas ; methods ; Hydrocarbons, Brominated ; analysis ; Workplace