1.Measurement of Left Ventricular Diastolic Function with Color M-mode Echocardiography in Patients with Acute Coronary Syndrome.
Juyup HAN ; Yongwhi PARK ; Donghun YANG ; Youngbae SEO ; Hunsik PARK ; Shungchull CHAE ; Jaeeun JUN ; Ehyun PARK
Journal of the Korean Society of Echocardiography 2001;9(2):97-104
BACKGROUND: Color M-mode doppler echocardiography has been suggested as a new noninvasive technique for assessing left ventricular diastolic function. The present study was performed to define the feasibility and value of color M-mode echocardiography for the assessment of left ventricular diastolic function in patients with acute coronary syndrome. METHODS: Thirty six patients with acute myocardial infarcion and twenty three patients with unstable angina were included (M/F=41/18, 61+/-12.2 years). Doppler study was performed using ATL HDI-3000 within 24 hours after the attack. In color M-mode study, ROP was measured with 'Front wave method' and 'Baseline shift method'. The patients were grouped into three groups based on E/A ratio and deceleration time (DT) in transmitral flow and S/D ratio in pulmonary venous flow; Group I=Normal pattern (E/A>1, S/D>1, DT>140 ms), Group II=Impaired relaxation pattern (E/A<1, DT>140 ms) and Group III=Pseudonormal/Restrictive pattern (E/A>1.5, S/D<1, with or without DT< or =140 ms). RESULT: Twenty two, thirty four, and three patients were assigned to Group I, II, III, respectively. The ROP could be measured with 'Front wave method' in 50 patients (84.7%), but with 'Baseline shift method' only in 19 patients (32.2%). ROP with 'Front wave method' was 65+/-25.7, 61+/-35.6, 71+/-35.2 cm/sec in Group I, II, III, respectively. There was no statistically significant difference in the value of ROP between group I and II (p>0.05). CONCLUSION: The ROP seems not to reflect the diastolic function in acute coronary syndrome, although it is measurable with the 'Front wave method' in most cases. The measurement of the ROP with 'Baseline shift method' is not feasible in the patients with acute coronary syndrome.
Acute Coronary Syndrome*
;
Angina, Unstable
;
Deceleration
;
Echocardiography*
;
Echocardiography, Doppler
;
Humans
;
Relaxation
2.Impact of Atrial Fibrillation on Patients Undergoing Transcatheter Aortic Valve Implantation (TAVI): The K-TAVI Registry
Sang Yoon LEE ; Ki Hong CHOI ; Taek Kyu PARK ; Jihoon KIM ; Eun Kyoung KIM ; Sung-Ji PARK ; Seung Woo PARK ; Hyeon-Cheol GWON ; Kiyuk CHANG ; Cheol Woong YU ; JuHan KIM ; Young Jin CHOI ; In-Ho CHAE ; Jae-Hwan LEE ; Jun-Hong KIM ; Jong Seon PARK ; Won-Jang KIM ; Young Won YOON ; Tae Hoon AHN ; Sang Rok LEE ; Byoung Joo CHOI ; Tae-Hyun YANG ; Cheol Ung CHOI ; Seung-Ho HUR ; Seong-Jin OH ; Han Cheol LEE ; HunSik PARK ; Hyo-Soo KIM ; Seung-Hyuk CHOI
Yonsei Medical Journal 2023;64(7):413-422
Purpose:
The incidence and prognostic implications of atrial fibrillation (AF) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI) are controversial, especially for Korean patients. Furthermore, the pattern of antithrombotic therapy for these patients is unknown. The present study sought to identify the impact of AF on Korean patients undergoing TAVI and demonstrate the status of antithrombotic therapy for these patients.
Materials and Methods:
A total of 660 patients who underwent TAVI for severe AS were recruited from the nationwide K-TAVI registry in Korea. The enrolled patients were stratified into sinus rhythm (SR) and AF groups. The primary endpoint was all-cause death at 1-year.
Results:
AF was recorded in 135 patients [pre-existing AF 108 (16.4%) and new-onset AF 27 (4.1%)]. The rate of all-cause death at 1 year was significantly higher in patients with AF than in those with SR [16.2% vs. 6.4%, adjusted hazard ratio (HR): 2.207, 95% confidence interval (CI): 1.182–4.120, p=0.013], regardless of the onset timing of AF. The rate of new pacemaker insertion at 1 year was also significantly higher in patients with AF than in those with SR (14.0% vs. 5.5%, adjusted HR: 3.137, 95%CI: 1.621–6.071, p=0.001).Among AF patients, substantial number of patients received the combination of multiple antithrombotic agents (77.8%), and the most common combination was that of aspirin and clopidogrel (38.1%).
Conclusion
AF was an independent predictor of 1-year mortality and new pacemaker insertion in Korean patients undergoing TAVI.