1.Prevalence and characteristics of impacted teeth in Korean orthodontic patients at ten university dental hospitals
Youn-Kyung CHOI ; Sung-Hun KIM ; Yong-Il KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Dong-Soon CHOI ; Ho-Jin KIM ; Kyung-A KIM ; Mo-Hyeon LEE ; Sung-Hwan CHOI ; Sung-Kwon CHOI ; Kyungmin Clara LEE ; Young-Mi JEON ; Sewoong OH ; Seorin JEONG
The Korean Journal of Orthodontics 2025;55(3):234-241
Objective:
This study aimed to investigate the prevalence and characteristics of impacted teeth (ITs) in orthodontic patients at university dental hospitals in Korea.
Methods:
This study included 14,774 patients who visited the Department of Orthodontics at 10 university dental hospitals in Korea between 2020 and 2022 and underwent orthodontic diagnosis. The prevalence and characteristics of ITs were investigated using orthodontic diagnostic records, radiographs, and diagnostic casts.
Results:
The prevalence of ITs, excluding third molar impaction, in Korean orthodontic patients was 13.6% (n = 2,014).The prevalence of ITs in pediatric orthodontic patients was 24.5% (n = 1,614).Of these patients, 68.2% had one IT, 27.5% had two ITs, 24.3% had bilateral IT, and 75.7% had unilateral IT. The most frequent IT was the maxillary canine (50.1%), followed by the mandibular second molar (11.7%), and maxillary second premolar (9.6%). An abnormal eruption path (46.5%) was the most frequent etiology. Orthodontic traction after surgical exposure (70.6%) was the most frequent treatment option. Among the patients with ITs, 29.8% had other dental anomalies, such as tooth agenesis (8.7%), microdontia (8.0%), and supernumerary teeth (5.1%). Furthermore, 50.8% had complications such as cystic lesions (18.3%), transposition (17.7%), and root resorption (14.8%).Among the patients with maxillary canine impaction, 62.2% had labial maxillary canine impaction and 21.1% had palatal maxillary canine impaction.
Conclusions
The prevalence of ITs in Korean orthodontic patients at university dental hospitals was high, particularly in pediatric orthodontic patients.
2.Pericapsular Nerve Group Block with Periarticular Injection for Pain Management after Total Hip Arthroplasty: A Randomized Controlled Trial
Hun Sik CHO ; Bo Ra LEE ; Hyuck Min KWON ; Jun Young PARK ; Hyeong Won HAM ; Woo-Suk LEE ; Kwan Kyu PARK ; Tae Sung LEE ; Yong Seon CHOI
Yonsei Medical Journal 2025;66(4):233-239
Purpose:
The purpose of this study was to compare the effectiveness of pericapsular nerve group (PENG) block with periarticular multimodal drug injection (PMDI) on postoperative pain management and surgical outcomes in patients who underwent total hip arthroplasty (THA). We hypothesized that PENG block with PMDI would exhibit superior effects on postoperative pain control after THA compared to PMDI alone.
Materials and Methods:
From April 2022 to February 2023, 58 patients who underwent THA were randomly assigned into two groups: PENG block with PMDI group (n=29) and PMDI-only group (n=29). Primary outcomes were postoperative numeric rating scale (NRS) at rest and during activity at 6, 24, and 48 hours postoperatively. Secondary outcomes were postoperative complications (nausea and vomiting), Richards-Campbell Sleep Questionnaire (RCSQ) score, length of hospital stay, Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index, Harris Hip Score (HHS), and total morphine usage after surgery.
Results:
There was no significant difference in postoperative pain for either resting NRS or active NRS. Postoperative nausea and vomiting, RCSQ score, length of hospital stay, WOMAC index, HHS, and total morphine usage exhibited no significant differences between the two groups.
Conclusion
Both groups showed no significant differences in postoperative pain and clinical outcomes, indicating that the addition of PENG block to PMDI does not improve pain management after applying the posterolateral approach of THA. PMDI alone during THA would be an efficient, fast, and safe method for managing postoperative pain. This article was registered with ClinicalTrials.gov (Gov ID: NCT05320913).
3.Evaluation of Image Quality and Scan Time Efficiency in Accelerated 3D T1-Weighted Pediatric Brain MRI Using Deep Learning-Based Reconstruction
Hyunsuk YOO ; Hee Eun MOON ; Soojin KIM ; Da Hee KIM ; Young Hun CHOI ; Jeong-Eun CHEON ; Joon Sung LEE ; Seunghyun LEE
Korean Journal of Radiology 2025;26(2):180-192
Objective:
This study evaluated the effect of an accelerated three-dimensional (3D) T1-weighted pediatric brain MRI protocol using a deep learning (DL)-based reconstruction algorithm on scan time and image quality.
Materials and Methods:
This retrospective study included 46 pediatric patients who underwent conventional and accelerated, pre- and post-contrast, 3D T1-weighted brain MRI using a 3T scanner (SIGNA Premier; GE HealthCare) at a single tertiary referral center between March 1, 2023, and April 30, 2023. Conventional scans were reconstructed using intensity Filter A (Conv), whereas accelerated scans were reconstructed using intensity Filter A (Fast_A) and a DL-based algorithm (Fast_DL).Image quality was assessed quantitatively based on the coefficient of variation, relative contrast, apparent signal-to-noise ratio (aSNR), and apparent contrast-to-noise ratio (aCNR) and qualitatively according to radiologists’ ratings of overall image quality, artifacts, noisiness, gray-white matter differentiation, and lesion conspicuity.
Results:
The acquisition times for the pre- and post-contrast scans were 191 and 135 seconds, respectively, for the conventional scan. With the accelerated protocol, these were reduced to 135 and 80 seconds, achieving time reductions of 29.3% and 40.7%, respectively. DL-based reconstruction significantly reduced the coefficient of variation, improved the aSNR, aCNR, and overall image quality, and reduced the number of artifacts compared with the conventional acquisition method (all P < 0.05). However, the lesion conspicuity remained similar between the two protocols.
Conclusion
Utilizing a DL-based reconstruction algorithm in accelerated 3D T1-weighted pediatric brain MRI can significantly shorten the acquisition time, enhance image quality, and reduce artifacts, making it a viable option for pediatric imaging.
4.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
5.Ultrafast MRI for Pediatric Brain Assessment in Routine Clinical Practice
Hee Eun MOON ; Ji Young HA ; Jae Won CHOI ; Seung Hyun LEE ; Jae-Yeon HWANG ; Young Hun CHOI ; Jung-Eun CHEON ; Yeon Jin CHO
Korean Journal of Radiology 2025;26(1):75-87
Objective:
To assess the feasibility of ultrafast brain magnetic resonance imaging (MRI) in pediatric patients.
Materials and Methods:
We retrospectively reviewed 194 pediatric patients aged 0 to 19 years (median 10.2 years) who underwent both ultrafast and conventional brain MRI between May 2019 and August 2020. Ultrafast MRI sequences included T1 and T2-weighted images (T1WI and T2WI), fluid-attenuated inversion recovery (FLAIR), T2*-weighted image (T2*WI), and diffusion-weighted image (DWI). Qualitative image quality and lesion evaluations were conducted on 5-point Likert scales by two blinded radiologists, with quantitative assessment of lesion count and size on T1WI, T2WI, and FLAIR sequences for each protocol. Wilcoxon signed-rank tests and intraclass correlation coefficient (ICC) analyses were used for comparison.
Results:
The total scan times for equivalent image contrasts were 1 minute 44 seconds for ultrafast MRI and 15 minutes 30 seconds for conventional MRI. Overall, image quality was lower in ultrafast MRI than in conventional MRI, with mean quality scores ranging from 2.0 to 4.8 for ultrafast MRI and 4.8 to 5.0 for conventional MRI across sequences (P < 0.001 for T1WI, T2WI, FLAIR, and T2*WI for both readers; P = 0.018 [reader 1] and 0.031 [reader 2] for DWI). Lesion detection rates on ultrafast MRI relative to conventional MRI were as follows: T1WI, 97.1%; T2WI, 99.6%; FLAIR, 92.9%; T2*WI, 74.1%; and DWI, 100%. The ICC (95% confidence interval) for lesion size measurements between ultrafast and conventional MRI was as follows: T1WI, 0.998 (0.996–0.999); T2WI, 0.998 (0.997–0.999); and FLAIR, 0.99 (0.985–0.994).
Conclusion
Ultrafast MRI significantly reduces scan time and provides acceptable results, albeit with slightly lower image quality than conventional MRI, for evaluating intracranial abnormalities in pediatric patients.
6.Prospective Evaluation of Accelerated Brain MRI Using Deep Learning-Based Reconstruction: Simultaneous Application to 2D Spin-Echo and 3D Gradient-Echo Sequences
Kyu Sung CHOI ; Chanrim PARK ; Ji Ye LEE ; Kyung Hoon LEE ; Young Hun JEON ; Inpyeong HWANG ; Roh Eul YOO ; Tae Jin YUN ; Mi Ji LEE ; Keun-Hwa JUNG ; Koung Mi KANG
Korean Journal of Radiology 2025;26(1):54-64
Objective:
To prospectively evaluate the effect of accelerated deep learning-based reconstruction (Accel-DL) on improving brain magnetic resonance imaging (MRI) quality and reducing scan time compared to that in conventional MRI.
Materials and Methods:
This study included 150 participants (51 male; mean age 57.3 ± 16.2 years). Each group of 50 participants was scanned using one of three 3T scanners from three different vendors. Conventional and Accel-DL MRI images were obtained from each participant and compared using 2D T1- and T2-weighted and 3D gradient-echo sequences. Accel-DL acquisition was achieved using optimized scan parameters to reduce the scan time, with the acquired images reconstructed using U-Net-based software to transform low-quality, undersampled k-space data into high-quality images. The scan times of Accel-DL and conventional MRI methods were compared. Four neuroradiologists assessed the overall image quality, structural delineation, and artifacts using Likert scale (5- and 3-point scales). Inter-reader agreement was assessed using Fleiss’ kappa coefficient. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated, and volumetric quantification of regional structures and white matter hyperintensities (WMHs) was performed.
Results:
Accel-DL showed a mean scan time reduction of 39.4% (range, 24.2%–51.3%). Accel-DL improved overall image quality (3.78 ± 0.71 vs. 3.36 ± 0.61, P < 0.001), structure delineation (2.47 ± 0.61 vs. 2.35 ± 0.62, P < 0.001), and artifacts (3.73 ± 0.72 vs. 3.71 ± 0.69, P = 0.016). Inter-reader agreement was fair to substantial (κ = 0.34–0.50). SNR and CNR increased in Accel-DL (82.0 ± 23.1 vs. 31.4 ± 10.8, P = 0.02; 12.4 ± 4.1 vs. 4.4 ± 11.2, P = 0.02). Bland-Altman plots revealed no significant differences in the volumetric measurements of 98.2% of the relevant regions, except in the deep gray matter, including the thalamus. Five of the six lesion categories showed no significant differences in WMH segmentation, except for leukocortical lesions (r = 0.64 ± 0.29).
Conclusion
Accel-DL substantially reduced the scan time and improved the quality of brain MRI in both spin-echo and gradientecho sequences without compromising volumetry, including lesion quantification.
7.Factors Associated with Postoperative Recurrence in Stage I to IIIA Non–Small Cell Lung Cancer with Epidermal Growth Factor Receptor Mutation: Analysis of Korean National Population Data
Kyu Yean KIM ; Ho Cheol KIM ; Tae Jung KIM ; Hong Kwan KIM ; Mi Hyung MOON ; Kyongmin Sarah BECK ; Yang Gun SUH ; Chang Hoon SONG ; Jin Seok AHN ; Jeong Eun LEE ; Jae Hyun JEON ; Chi Young JUNG ; Jeong Su CHO ; Yoo Duk CHOI ; Seung Sik HWANG ; Chang Min CHOI ; Seung Hun JANG ; Jeong Uk LIM ;
Cancer Research and Treatment 2025;57(1):83-94
Purpose:
Recent development in perioperative treatment of resectable non–small cell lung cancer (NSCLC) have changed the landscape of early lung cancer management. The ADAURA trial has demonstrated the efficacy of adjuvant osimertinib treatment in resectable NSCLC patients; however, studies are required to show which subgroup of patients are at a high risk of relapse and require adjuvant epidermal growth factor receptor (EGFR) tyrosine kinase inhibitor treatment. This study evaluated risk factors for postoperative relapse among patients who underwent complete resection.
Materials and Methods:
Data were obtained from the Korean Association for Lung Cancer Registry (KALC-R), a database created using a retrospective sampling survey by the Korean Central Cancer Registry (KCCR) and the Lung Cancer Registration Committee.
Results:
A total of 3,176 patients who underwent curative resection was evaluated. The mean observation time was approximately 35.4 months. Among stage I to IIIA NSCLC patients, the EGFR-mutant subgroup included 867 patients, and 75.2%, 11.2%, and 11.8% were classified as stage I, stage II, and stage III, respectively. Within the EGFR-mutant subgroup, 44 (5.1%) and 121 (14.0%) patients showed early and late recurrence, respectively. Multivariate analysis on association with postoperative relapse among the EGFR-mutant subgroup showed that age, pathologic N and TNM stages, pleural invasion status, and surgery type were independent significant factors.
Conclusion
Among the population that underwent complete resection for early NSCLC with EGFR mutation, patients with advanced stage, pleural invasion, or limited resection are more likely to show postoperative relapse.
8.Comparative Analysis of Ultrasound and Surgical Findings in Anatomical Variations of de Quervain’s Disease
Young Seok LEE ; Wan-Sun CHOI ; Seung Hun BAEK ; Hyunwoo KANG ; Chang-Hun LEE
Clinics in Orthopedic Surgery 2025;17(2):308-316
Background:
This study compares ultrasound and surgical findings of anatomical variations in de Quervain’s disease.
Methods:
Seventy-four wrists from patients with unilateral de Quervain’s disease were examined through ultrasonography and surgery. Presence of intracompartment septum, abductor pollicis longus (APL) slips, and selective stenosis were verified by both methods. Two orthopedic surgeons assessed ultrasound findings for intra- and interobserver reliability.
Results:
Amongst 74 participants (43 women and 31 men), 60.8% had a complete septum, 31.1% had an incomplete septum, and 8.1% had no septum; 70.3% had multi-slip APL and 66.2% had extensor pollicis brevis stenosis. Surgical and ultrasonographic findings displayed a high level of sensitivity and specificity. Intraobserver reliability was high, and interobserver reliability was substantial.
Conclusions
The study confirms ultrasonography’s reliability in identifying anatomical variations in de Quervain’s disease, with high sensitivity, specificity, and substantial intra- and interobserver reliability, emphasizing its usefulness in preoperative assessment and planning.
9.Comparison between Suture-Button Technique with Syndesmotic Repair and Screw Fixation Technique for Complete Ankle Syndesmotic Injury: Biomechanical Cadaveric Study
Hong Seop LEE ; Sung Hwan KIM ; Ki Won YOUNG ; Woo Jong KIM ; Dong-Il CHEON ; Sung Hun WON ; Sang Heon LEE ; Seung Jin CHOI ; Young Koo LEE
Clinics in Orthopedic Surgery 2025;17(2):324-330
Background:
The tibiofibular syndesmosis is essential for preserving the stability of the ankle. Acute syndesmotic injuries with evident or latent instability usually warrant surgical interventions. This cadaveric study examines and compares biomechanical characteristics between the following treatments for syndesmosis injuries: suture-button fixation plus syndesmotic repair and screw fixation.
Methods:
The lower extremities of 10 cadavers disarticulated at the knee joints were used, yielding 20 feet. Ten feet underwent surgery using the suture-button fixation with syndesmotic repair, while the remaining 10 feet underwent surgery using screw fixation. Before surgical treatment of syndesmosis injuries, each cadaveric lower limb underwent preliminary physiological cyclic loading, which was followed by a series of postfixation cyclic loading tests after the surgical procedure.
Results:
Our principal finding is that suture-button fixation with syndesmotic repair provided torsional strength comparable to that of screw fixation. The mean failure torque did not differ between the 2 groups, but the rotational stiffness was significantly lower in the suture-button fixation/augmentation group.
Conclusions
Suture-button fixation/augmentation facilitates flexible (physiological) syndesmosis movement and may be a useful alternative treatment for ankle syndesmosis injury.
10.Evaluation of Image Quality and Scan Time Efficiency in Accelerated 3D T1-Weighted Pediatric Brain MRI Using Deep Learning-Based Reconstruction
Hyunsuk YOO ; Hee Eun MOON ; Soojin KIM ; Da Hee KIM ; Young Hun CHOI ; Jeong-Eun CHEON ; Joon Sung LEE ; Seunghyun LEE
Korean Journal of Radiology 2025;26(2):180-192
Objective:
This study evaluated the effect of an accelerated three-dimensional (3D) T1-weighted pediatric brain MRI protocol using a deep learning (DL)-based reconstruction algorithm on scan time and image quality.
Materials and Methods:
This retrospective study included 46 pediatric patients who underwent conventional and accelerated, pre- and post-contrast, 3D T1-weighted brain MRI using a 3T scanner (SIGNA Premier; GE HealthCare) at a single tertiary referral center between March 1, 2023, and April 30, 2023. Conventional scans were reconstructed using intensity Filter A (Conv), whereas accelerated scans were reconstructed using intensity Filter A (Fast_A) and a DL-based algorithm (Fast_DL).Image quality was assessed quantitatively based on the coefficient of variation, relative contrast, apparent signal-to-noise ratio (aSNR), and apparent contrast-to-noise ratio (aCNR) and qualitatively according to radiologists’ ratings of overall image quality, artifacts, noisiness, gray-white matter differentiation, and lesion conspicuity.
Results:
The acquisition times for the pre- and post-contrast scans were 191 and 135 seconds, respectively, for the conventional scan. With the accelerated protocol, these were reduced to 135 and 80 seconds, achieving time reductions of 29.3% and 40.7%, respectively. DL-based reconstruction significantly reduced the coefficient of variation, improved the aSNR, aCNR, and overall image quality, and reduced the number of artifacts compared with the conventional acquisition method (all P < 0.05). However, the lesion conspicuity remained similar between the two protocols.
Conclusion
Utilizing a DL-based reconstruction algorithm in accelerated 3D T1-weighted pediatric brain MRI can significantly shorten the acquisition time, enhance image quality, and reduce artifacts, making it a viable option for pediatric imaging.

Result Analysis
Print
Save
E-mail