1.The effect of hypertension on the progression of renal insufficiency in chronic renal failure patients.
Dae Suk HAN ; Kyu Hun CHOI ; Young Ki KIM ; Dong Hun CHA ; Ho Yung LEE ; Kyo Sun KIM
Korean Journal of Nephrology 1991;10(2):135-144
No abstract available.
Humans
;
Hypertension*
;
Kidney Failure, Chronic*
;
Renal Insufficiency*
2.The effect of hypertension on the progression of renal insufficiency in chronic renal failure patients.
Dae Suk HAN ; Kyu Hun CHOI ; Young Ki KIM ; Dong Hun CHA ; Ho Yung LEE ; Kyo Sun KIM
Korean Journal of Nephrology 1991;10(2):135-144
No abstract available.
Humans
;
Hypertension*
;
Kidney Failure, Chronic*
;
Renal Insufficiency*
3.The effect of low temperature aging on the mechanical property & phase stability of Y-TZP ceramics.
Hyung Tae KIM ; Jung Suk HAN ; Jae Ho YANG ; Jai Bong LEE ; Sung Hun KIM
The Journal of Advanced Prosthodontics 2009;1(3):113-117
STATEMENT OF PROBLEM: Recently Yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) has been introduced due to superior flexural strength and fracture toughness compared to other dental ceramic systems. Although zirconia has outstanding mechanical properties, the phenomenon of decrease in the life-time of zirconia resulted from degradation in flexural strength after low temperature aging has been reported. PURPOSE: The objective of this study was to investigate degradation of flexural strength of Y-TZP ceramics after various low temperature aging treatments and to evaluate the phase stability and micro-structural change after aging by using X-ray diffraction analysis and a scanning electron microscope (SEM). MATERIAL AND METHODS: Y-TZP blocks of Vita In-Ceram YZ (Vita Zahnfabrik, Bad Sackingen, Germany) were prepared in 40 mm (length) x 4 mm (width) x 3 mm (height) samples. Specimens were artificially aged in distilled water by heat-treatment at a temperature of 75, 100, 125, 150, 175, 200, and 225degrees C for 10 hours, in order to induce the phase transformation at the surface. To measure the mechanical property, the specimens were subjected to a four-point bending test using a universal testing machine (Instron model 3365; Instron, Canton, Mass, USA). In addition, X-ray diffraction analysis (DMAX 2500; Rigaku, Tokyo, Japan) and SEM (Hitachi s4700; Jeol Ltd, Tokyo, Japan) were performed to estimate the phase transformation. The statistical analysis was done using SAS 9.1.3 (SAS institute, USA). The flexural strength data of the experimental groups were analyzed by one-way analysis of variance and to detect statistically significant differences (alpha= .05). RESULTS: The mean flexural strength of sintered Vita In-Ceram YZ without autoclaving was 798 MPa. When applied aging temperature at below 125degrees C for 10 hours, the flexural strength of Vita In-Ceram YZ increased up to 1,161 MPa. However, at above 150degrees C, the flexural strength started to decrease. Although low temperature aging caused the tetragonal-to-monoclinic phase transformation related to temperature, the minimum flexural strength was above 700 MPa. CONCLUSION: The monoclinic phase started to appear after aging treatment above 100degrees C. With the higher aging temperature, the fraction of monoclinic phase increased. The ratio of monoclinic/tetragonal + monoclinic phase reached a plateau value, circa 75% above 175degrees C. The point of monoclinic concentration at which the flexural strength begins to decrease was between 12% and 54%.
Aged
;
Aging
;
Aluminum Oxide
;
Ceramics
;
Collodion
;
Dental Porcelain
;
Electrons
;
Humans
;
Phenothiazines
;
Tokyo
;
Water
;
X-Ray Diffraction
;
Yttrium
;
Zirconium
4.Comparison of polymer-based temporary crown and fixed partial denture materials by diametral tensile strength.
Seung Ryong HA ; Jae Ho YANG ; Jai Bong LEE ; Jung Suk HAN ; Sung Hun KIM
The Journal of Advanced Prosthodontics 2010;2(1):14-17
PURPOSE: The purpose of this study was to investigate the diametral tensile strength of polymer-based temporary crown and fixed partial denture (FPD) materials, and the change of the diametral tensile strength with time. MATERIAL AND METHODS: One monomethacrylate-based temporary crown and FPD material (Trim) and three dimethacrylate-based ones (Protemp 3 Garant, Temphase, Luxtemp) were investigated. 20 specimens (the empty set 4 mm x 6 mm) were fabricated and randomly divided into two groups (Group I: Immediately, Group II: 1 hour) according to the measurement time after completion of mixing. Universal Testing Machine was used to load the specimens at a cross-head speed of 0.5 mm/min. The data were analyzed using one-way ANOVA, the multiple comparison Scheffe test and independent sample t test (alpha = 0.05). RESULTS: Trim showed severe permanent deformation without an obvious fracture during loading at both times. There were statistically significant differences among the dimethacrylate-based materials. The dimethacrylate-based materials presented an increase in strength from 5 minutes to 1 hour and were as follows: Protemp 3 Garant (23.16 - 37.6 MPa), Temphase (22.27 - 28.08 MPa), Luxatemp (14.46 - 20.59 MPa). Protemp 3 Garant showed the highest value. CONCLUSION: The dimethacrylate-based temporary materials tested were stronger in diametral tensile strength than the monomethacrylate-based one. The diametral tensile strength of the materials investigated increased with time.
Acrylic Resins
;
Bisphenol A-Glycidyl Methacrylate
;
Collodion
;
Composite Resins
;
Crowns
;
Denture, Partial, Fixed
;
Methacrylates
;
Polymethacrylic Acids
;
Tensile Strength
5.A study on the fracture strength of collarless metal-ceramic fixed partial dentures.
Jong Wook YOON ; Sung Hun KIM ; Jai Bong LEE ; Jung Suk HAN ; Jae Ho YANG
The Journal of Advanced Prosthodontics 2010;2(4):134-141
PURPOSE: The objective of this study was to evaluate fracture strength of collarless metal-ceramic FPDs according to their metal coping designs. MATERIALS AND METHODS: Four different facial margin design groups were investigated. Group A was a coping with a thin facial metal collar, group B was a collarless coping with its facial metal to the shoulder, group C was a collarless coping with its facial metal 1 mm short of the shoulder, and group D was a collarless coping with its facial metal 2 mm short of the shoulder. Fifteen 3-unit collarless metal-ceramic FPDs were fabricated in each group. Finished FPDs were cemented to PBT (Polybutylene terephthalate) dies with resin cement. The fracture strength test was carried out using universal testing machine (Instron 4465, Instron Co., Norwood MA, USA) at a cross head speed of 0.5 mm/min. Aluminum foil folded to about 1 mm of thickness was inserted between the plunger tip and the incisal edge of the pontic. Vertical load was applied until catastrophic porcelain fracture occurred. RESULTS: The greater the bulk of unsupported facial shoulder porcelain was, the lower the fracture strength became. However, there were no significant differences between experimental groups (P > .05). CONCLUSION: All groups of collarless metal-ceramic FPDs had higher fracture strength than maximum incisive biting force. Modified collarless metal-ceramic FPD can be an alternative to all-ceramic FPDs in clinical situations.
Aluminum
;
Bites and Stings
;
Collodion
;
Dental Porcelain
;
Denture, Partial, Fixed
;
Head
;
Resin Cements
;
Shoulder
6.Palmoplantar Eccrine Hidradenitis.
Hong Suk KIM ; Han Gil CHUNG ; Sung Ku AHN ; Seung Hun LEE
Korean Journal of Dermatology 2000;38(5):697-699
No Abstract Available.
Hidradenitis*
7.Factors affecting the response to gemfibrozil in hypertriglyceridemic continuous ambulatory peritoneal dialysis patients.
Seoung Hwan SOHN ; Heung Soo KIM ; Kyu Hun CHOI ; Ho Yung LEE ; Dae Suk HAN
Korean Journal of Nephrology 1992;11(3):270-278
No abstract available.
Gemfibrozil*
;
Humans
;
Peritoneal Dialysis, Continuous Ambulatory*
8.Esthetic restorations of maxillary anterior teeth with orthodontic treatment and porcelain laminate veneers: a case report.
Ji Eun MOON ; Sung Hun KIM ; Jung Suk HAN ; Jae Ho YANG ; Jai Bong LEE
The Journal of Advanced Prosthodontics 2010;2(2):61-63
If orthodontists and restorative dentists establish the interdisciplinary approach to esthetic dentistry, the esthetic and functional outcome of their combined efforts will be greatly enhanced. This article describes satisfying esthetic results obtained by the distribution of space for restoration by orthodontic treatment and porcelain laminate veneers in uneven space between maxillary anterior teeth. It is proposed that the use of orthodontic treatment for re-distribution of the space and the use of porcelain laminate veneers to alter crown anatomy provide maximum esthetic and functional correction for patients with irregular interdental spacing.
Crowns
;
Dental Porcelain
;
Dentistry
;
Dentists
;
Humans
;
Tooth
9.Esthetic restorations of maxillary anterior teeth with orthodontic treatment and porcelain laminate veneers: a case report.
Ji Eun MOON ; Sung Hun KIM ; Jung Suk HAN ; Jae Ho YANG ; Jai Bong LEE
The Journal of Advanced Prosthodontics 2010;2(2):61-63
If orthodontists and restorative dentists establish the interdisciplinary approach to esthetic dentistry, the esthetic and functional outcome of their combined efforts will be greatly enhanced. This article describes satisfying esthetic results obtained by the distribution of space for restoration by orthodontic treatment and porcelain laminate veneers in uneven space between maxillary anterior teeth. It is proposed that the use of orthodontic treatment for re-distribution of the space and the use of porcelain laminate veneers to alter crown anatomy provide maximum esthetic and functional correction for patients with irregular interdental spacing.
Crowns
;
Dental Porcelain
;
Dentistry
;
Dentists
;
Humans
;
Tooth
10.Biomechanical evaluation of dental implants with different surfaces: Removal torque and resonance frequency analysis in rabbits.
Jung Woo KOH ; Jae Ho YANG ; Jung Suk HAN ; Jai Bong LEE ; Sung Hun KIM
The Journal of Advanced Prosthodontics 2009;1(2):107-112
STATEMENT OF PROBLEM: Macroscopic and especially microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Dental implants with modified surfaces have shown stronger osseointegration than implants which are only turned (machined). Advanced surface modification techniques such as anodic oxidation and Ca-P application have been developed to achieve faster and stronger bonding between the host bone and the implant. PURPOSE: The purpose of this study was to investigate the effect of surface treatment of titanium dental implant on implant stability after insertion using the rabbit tibia model. MATERIAL AND METHODS: Three test groups were prepared: sandblasted, large-grit and acid-etched (SLA) implants, anodic oxidized implants, and anodized implants with Ca-P immersion. The turned implants served as control. Twenty rabbits received 80 implants in the tibia. Resonance frequencies were measured at the time of implant insertion, 2 weeks and 4 weeks of healing. Removal torque values (RTV) were measured 2 and 4 weeks after insertion. RESULTS: The implant stability quotient (ISQ) values of implants for resonance frequency analysis (RFA) increased significantly (P < .05) during 2 weeks of healing period although there were no significant differences among the test and control groups (P > .05). The test and control implants also showed significantly higher ISQ values during 4 weeks of healing period (P < .05). No significant differences, however, were found among all the groups. All the groups showed no significant differences in ISQ values between 2 and 4 weeks after implant insertion (P > .05). The SLA, anodized and Ca-P immersed implants showed higher RTVs at 2 and 4 weeks of healing than the machined one (P < .05). However, there was no significant difference among the experimental groups. CONCLUSION: The surface-modified implants appear to provide superior implant stability to the turned one. Under the limitation of this study, however, we suggest that neither anodic oxidation nor Ca-P immersion techniques have any advantage over the conventional SLA technique with respect to implant stability.
Dental Implants
;
Imidazoles
;
Immersion
;
Nitro Compounds
;
Osseointegration
;
Rabbits
;
Tibia
;
Titanium
;
Torque