1.Variance analysis of circulation demand resources deployment in library-taking the Chongqing Medical University as an example
Lu CHEN ; Danmei XIE ; Lei JIN ; Huiqun LV ; Chunguang WENG
Chinese Journal of Medical Education Research 2011;10(8):1011-1013
Bibliometrics analysis has been made on the statistics of Chinese books circulation and order data through Chongqing Medical University. Goldlib Library Management System. And analysis relativity and variation between circulation needs and resource allocation for the past 10 years has also been made.
2.0D-1D coupling model and 3D fluid-structure interaction model based on coronary CT angiography for displaying hemodynamic characteristics of coronary artery stenosis
Shanfeng LIU ; Xiaochen LU ; Hao TIAN ; Huiqun WU
Chinese Journal of Medical Imaging Technology 2024;40(8):1236-1241
Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Based on CCTA data of the stenosed left anterior descending branch(LAD)in a patient with coronary heart disease,an 0D-1D coupling model and 3D FSI model were built,respectively.Then hemodynamic characteristic indexes,including the pressure,flow velocity and wall shear stress(WSS)were obtained in every 0.01 s during 1 s at 5 sampling points(i.e.sampling point 1-5)using these 2 models,respectively,and the consistencies of the results between models were evaluated with Spearman correlation coefficient rs.Results The time consuming for construction of 0D-1D coupling model and 3D FSI model was 0.033 min and 704 min,respectively.Both models showed basically distribution of the pressure,flow velocity and WSS of the stenosed LAD.For more details,the pressure at the stenosed segment of LAD and the proximal segment of stenosis were both higher,which gradually decreased at the distal segment of stenosis,and the flow velocity at the proximal segment of stenosis was in a relatively slow and uniform condition,with significantly increased flow velocity and WSS at the stenosed segment.Compared with 3D FSI model,0D-1D vascular coupling model was relatively unrefined and lack of distal flow lines when displaying blood flow velocity.For sampling point 2 at the stenosed segment of LAD,no significant consistency for pressure between 2 models was found(P=0.118),but strong consistency for the flow velocity and WSS(rs=0.730,0.807,both P<0.05).The consistencies of pressure,flow velocity and WSS between 2 models at the proximal and distal segment of stenosis,i.e.1,3-5 sampling points were week to moderate(rs=0.237-0.669,all P<0.05).Conclusion 0D-1D coupling model exhibited outstanding computational efficiency and might provide relatively reasonable results,while 3D FSI model showed higher accuracy for details and streamline when simulating LAD stenosis.
3.A survey concerning the knowledge of the Chinese Guidelines of Diabetes Prevention and Treatment among medical staff from hospitals at different levels in Shanghai
Yingxia ZHOU ; Liebin ZHAO ; Luo LU ; Bin DONG ; Lizhen SU ; Jingyan TIAN ; Zhiqin CUI ; Aiping MA ; Min LIU ; Huiqun HUANG ; Jialin YANG ; Ling CHEN ; Hongguang SHENG ; Fengdi LU ; Yingyao CHEN ; Guang NING
Chinese Journal of Endocrinology and Metabolism 2011;27(8):636-638
To analyze and evaluate the knowledge of Chinese Guidelines of Diabetes Prevention and Treatment in Shanghai medical staff. 175 medical staff working in endocrinology or community health were enrolled and evaluated by a questionnaire of guidelines about the state of professional, training, and related knowledge. Only 16. 6% medical staffwere trained about the guidelines( 46. 67% from the general hospitals, 14. 75% from secod-level hospital and 7. 14% persons from the community hospitals, P<0. 01 ). The total correct answer rate of the guidelines was 37. 36%. The correct rate of community hospitals was lower than others( P<0. 05 ). The rate of doctors' was higher than nurses'( P<0. 05 ). There were difference between doctors and nurses with the key point of diabetes care knowledge in different level hospitals. The effective method of clinical training in diabetes care should be explored. We still have to work hard to promote the effect of diabetes control and prevention. Effective training about the guidelines should be enhanced. The cooperation between general hospitals and community health institutions in diabetes prevention and treatment should be enhanced.
4.Application of 64 slice spiral CT low dose technique in paranasal sinus scanning in children
Hangmei CAI ; Huiqun LU ; Xiaojie XU ; Xiaopeng DAI ; Yinxin DING ; Xiangyang YE ; Bo YE
Journal of Clinical Medicine in Practice 2018;22(11):109-110,113
Objective To explore the application of 64 slice low dose spiral CT in pediatric paranasal sinus examination.Methods Sixty children with paranasal sinuses were randomly divided into three groups(control group,low dose 1 group,low dose 2 group),and were given conventional dose scanning(100 KV in tube voltage,100 mA in tube current),low dose scanning(100 KV in tube voltage,45 mA in tube current),and low dose scanning (100KV in tube voltage,25 mA in tube current).The single scan weighted CT dose index (CTDIw) of each patient was recorded and compared;and the quality of the scanned images of each group was evaluated by two chief physicians by blind method.Results Compared with conventional dose group,low dose 1,2 groups had significantly lower CTDIw,and the dose decreased for 59.23% and 72.42% respectively.The image quality of the low-dose 1 group did not change significantly,and all the images could meet the requirements of clinical diagnosis;but the image quality of the low-dose 2 group decreased significantly,and the images of 3 patients could not meet the requirements of clinical diagnosis.Conclusion Appropriate reduction of scanning parameters for paranasal sinuses children can not only obtain good quality images,but also effectively reduce the radiation dose of patients.
5.Application of 64 slice spiral CT low dose technique in paranasal sinus scanning in children
Hangmei CAI ; Huiqun LU ; Xiaojie XU ; Xiaopeng DAI ; Yinxin DING ; Xiangyang YE ; Bo YE
Journal of Clinical Medicine in Practice 2018;22(11):109-110,113
Objective To explore the application of 64 slice low dose spiral CT in pediatric paranasal sinus examination.Methods Sixty children with paranasal sinuses were randomly divided into three groups(control group,low dose 1 group,low dose 2 group),and were given conventional dose scanning(100 KV in tube voltage,100 mA in tube current),low dose scanning(100 KV in tube voltage,45 mA in tube current),and low dose scanning (100KV in tube voltage,25 mA in tube current).The single scan weighted CT dose index (CTDIw) of each patient was recorded and compared;and the quality of the scanned images of each group was evaluated by two chief physicians by blind method.Results Compared with conventional dose group,low dose 1,2 groups had significantly lower CTDIw,and the dose decreased for 59.23% and 72.42% respectively.The image quality of the low-dose 1 group did not change significantly,and all the images could meet the requirements of clinical diagnosis;but the image quality of the low-dose 2 group decreased significantly,and the images of 3 patients could not meet the requirements of clinical diagnosis.Conclusion Appropriate reduction of scanning parameters for paranasal sinuses children can not only obtain good quality images,but also effectively reduce the radiation dose of patients.