1.Meta-analysis of influence of TNF-α and NSE levels in cerebrospinal fluid on children with viral encephalitis
Yan WANG ; Huijie HUANG ; Bin LI
Chongqing Medicine 2017;46(24):3366-3369
Objective To systematically evaluate the influence of TNF-α and NSE levels in cerebrospinal fluid on Chinese children with viral encephalitis (VE).Methods Literature about the influence of TNF-α and NSE levels in cerebrospinal fluid on Chinese children with VE,which were published before Nov.1,2016,were searched in databases including CNKI,Wanfang Data,Cochrane Library and PubMed.And the case-control study about the TNF-α and NSE levels in cerebrospinal fluid between Children with VE (VE group) and children without VE (control group) were included in this study,and the quality evaluation was implemented and the data were extracted.And then the RevMan 5.3 was used to carry out the meta-analysis.Results Nine case-control studies were included in this study,involving 536 cases in the VE group and 284 cases in the control group.The results showed that the level of TNF-α and NSE in cerebrospinal fluid of the VE group were all significantly higher than that of the control group,and the differences was statistically significant [SMD=1.75,95%CI:1.56-1.93,P<0.01;SMD=1.34,95%CI:1.17-1.51,P<0.01].Conclusion The levels of TNF-α and NSE in cerebrospinal fluid are positively correlated with the incidence of VE in Chinese children.
2.A Preliminary Study of Acoustic Characteristics of Snoring Sound in Patients with Obstructive Sleep Apnea/Hypopnea Syndrome (OSAHS) and with Simple Snoring
Huijie XU ; Lisheng YU ; Weining HUANG ; Lan CHEN ; Yuxia HE
Journal of Audiology and Speech Pathology 2009;17(3):235-238
Objective To investigate the acoustic characteristics of snoring sound in patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and with simple snoring. Methods 22 patients with OSAHS and 15 with simple snoring were included in this study. Natural overnight snoring was digitally recorded and portable sleep mo-nitoring was performed simultaneously. 10 snores, which were the 1st snores after 10 cycles of obstructive apnea, from each patient in OSAHS group, and 10 snores from each patient in simple snoring group were analyzed in the time and frequency domains. Results The sound waves of snoring in the two groups exhibited different patterns both in the time and frequency domains. The snoring spectrum of patients with simple snoring showed distinct fun-damental- harmonic structures which were not clear in patients with OSAHS. The central frequency of the patients with OSAHS was higher, and 800 Hz power ratio was lower than those of the patients with simple snoring. In the OSAHS group, the central frequency of the patients with moderate-to-severe OSAHS was higher, and 800 Hz power ratio was lower than those of the patients with mild OSAHS. The differences of the two parameters were of statistical significance. Conclusion The snoring sounds in patients with OSAHS and with simple snoring have dif-ferent characteristics in time and frequency domains, indicating that it is feasible to research the OSAHS by way of snore monitoring and analyzing technique.
4.The influence factors of sound pressure level parameters in patients with simple snoring and obstructive sleep apnea hypopnea syndrom.
Zhan GAO ; Huijie XU ; Weining HUANG ; Hao PENG ; Yuxia HE
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2015;29(11):966-969
OBJECTIVE:
To discuss the main influence factors of sound pressure level parameters in patients with simple snoring (SS) and obstructive sleep apnea hypopnea syndrom (OSAHS).
METHOD:
Eighty-four cases with snoring disease underwent polysomnography and simultaneously snoring sound pressure level recording. The correlations between AHI, age, BMI, abdomen circumference, neck circumference, the lowest oxygen saturation total apnea time and sound pressure level parameters: equivalent continuous sound level(LAeq)and maximum sound pressure level(L10) were analyzed.
RESULT:
LAeq was significantly correlated to AHI (P= 0. 000) and BMI (P= 0. 007), and the odd ratios of AHI and BMI were 5. 74,2. 09 respectively, but it was unrelated to age, abdomen circumference, neck circumference, the lowest oxygen saturation and total apnea time. A significantly association also existed between L10 and AHI(P=0. 000), BMI(P=0. 032), and the odd ratios were 4. 11 and 2. 33 respectively. Other factors had nothing to do with L10.
CONCLUSION
The main factors which affect the snoring sound pressure level parameters LAeq and L10 are AHI and BMI.
Humans
;
Polysomnography
;
Pressure
;
Sleep Apnea, Obstructive
;
physiopathology
;
Snoring
;
physiopathology
;
Sound
5.Pharmacokinetic characteristics of telmisartan in Chinese healthy volunteers
Yuqing XIONG ; Xinhua LI ; Peng HUANG ; Huijie ZHANG ; Wenwe XU
Chinese Pharmacological Bulletin 2003;0(09):-
Objective To explore the pharmacokinetic characteristics of telmisartan in Chinese healthy volunteers. Methods 9 Chinese male healthy volunteers were divided into receiving orally a single dose of 40, 80, 120 mg telmisartan tablets respectively, in latin square design study. After administration of telmisartan tablets, the plasma concentration was determined by HPLC with fluorescent detection. The pharmacokinetic parameters were analyzed by 3P97 program. Results It was found that plasma levels increased after orally increased dosages of telmisartan in the healthy volunteers in a nor-dose-dependent manner. The pharmacokinetic parameters were calculated the follows: AUC 0-96 of three different dosages (40, 80,120 mg) were (895.03?364.53), ( 3 030.34? 1 454.80) and ( 13 570.44? 3 551.54) ?g?h -1?L -1; and C max were (60.71?28.10), (214.05?74.14) and (978.32?234.89) ?g?L -1. There were significant differences in AUC 0-t/dose, C max/dose between the groups (P
6.Comparison on the positive detection rate of allergen specific IgE measured with the systems between fluorescence enzyme immunoassay and western blot
Shiqing YANG ; Li XIANG ; Huijie HUANG ; Yongge LIU
International Journal of Pediatrics 2021;48(3):195-201
Objective:To compare the difference on the positive detection rate of the main aeroallergens and food allergens specific IgE measured with the systems between fluorescence enzyme immunoassay(FEIA, referred to as ImmunoCAP system)and western blot(referred to as Allergy Screen system), in order to provide a basis for the rational application of methods and interpretation of the test results.Methods:The clinical information and sIgE test results data were collected from a total of 458 cases of allergic diseases from October 2017 to April 2019 in the outpatient clinic of Allergy Department in Beijing Children′s Hospital.All of the 458 cases were detected for a panel of common aeroallergens and food allergens sIgE level in their serum with the Allergy Screen system.Simultaneously, the above 141 cases were detected main aeroallergen and food allergen sIgE with ImmunoCAP system, while 303 cases only for aeroallergens and 14 cases only for food allergens.All of the cases were divided into three different phenotype groups according to the main target organ and diagnosis such as airway allergic disease group( N=293), skin allergic disease group( N=14)and multi-system allergic disease group( N=151). Meanwhile, three different age groups were referred to as <3 years old group( N=97), 3 to 6 years old group(3 years and 6 years included)( N=186)and >6 years old group( N=175). The same kinds of the allergens included in the two systems were house dust mite(HDM), cat dander, dog dander, egg white, milk, crab, shrimp, therefore data of sIgE to those seven allergens were compared. Results:In all the enrolled cases, the positive detection rate of HDM, egg white and milk sIgE detected by ImmunoCAP system were significantly higher than those by Allergy Screen system(30.6%, 36.1% and 43.2% vs 21.2%, 21.3% and 21.3%). Among the disease groups, the positive detection rate of HDM sIgE detected by ImmunoCAP system was significantly higher in the airway allergic disease group and multi-system allergic disease group than those by Allergy Screen system, respectively(33.7% and 24.6% vs 23.4% and 16.2%). The positive detection rate of egg white and milk sIgE detected by ImmunoCAP system in the multi-system allergic disease group was significantly higher than those by Allergy Screen system, respectively(47.6% and 47.6% vs 26.2% and 25.2%). There was no significant difference in the positive detection rate of cat dander, dog dander, crab and shrimp sIgE among the disease groups.The positive detection rate of HDM sIgE detected by ImmunoCAP system in all of the age groups were significantly higher than those by Allergy Screen system, respectively(14.9%, 26.9% and 42.3% vs 5.7%, 17.6% and 32.6%). The positive detection rate of cat dander sIgE detected by ImmunoCAP system in <3 years old group was significantly lower than that by Allergy Screen system(6.9% vs 16.1%). The positive detection rate of egg white sIgE detected by ImmunoCAP system in the <3 years old group and the 3 to 6 years old group were higher than those by Allergy Screen system, respectively(47.1% and 33.3% vs 32.4% and 15.0%). The difference in the positive detection rate of milk sIgE detected by these two methods in the <3 years old group and the 3 to 6 years old group was similar to the egg white.Conclusion:According to the analysis of seven kinds of major aeroallergen and food allergen sIgE results, there are differences between the two methods to detect HDM, cat dander, egg white and milk sIgE.It depends on the type of allergic disease and age.The positive detection rates of dog dander, crab, and shrimp sIgE detected by the two methods are consistent.In clinical application, comprehensive analysis should be made, testing methods should be selected rationally, and the results should be interpreted scientifically.
7.Study on Anti-oxidative Effects of Spirulina Kinase in vitro
Yuanheng HUANG ; Hui PANG ; Huijie WANG ; Qinrong LI ; Shuyu JI ; Weiran HUANG ; Jiajie LIN ; Yingxin LI
China Pharmacy 2016;27(16):2184-2186
OBJECTIVE:To study the anti-oxidative effects of spirulina kinase (SPK) in vitro. METHODS:The methods of phenanthroine-Fe2+ oxidation method,DPPH and auto-oxidation of pyrogallol were used to measure the effects of different concen-trations of SPK on scavenging hydroxyl (OH-) free radical,DPPH free radical and superoxide anion (O2-) free radical;IC50 of SPK was calculated. Prussian blue reaction was used to determine total reducing ability(by absorbance)of different concentrations of SPK to Fe3+. Vitamin C(VC)was used as positive control in above trials. RESULTS:SPK could eliminate the OH-free radical, DPPH free radical and O2- free radical in concentration-dependant manner,and the maximum elimination rate of SPK to OH- free radical and DPPH free radical were 86.82% and 78.98%(IC50 were 54.31,0.636 g/L),which were higher than VC (64.77%, 73.49%). The maximum elimination rate of SPK to O2- free radical was 78.31%(IC50 was 3.918 g/L),which was lower than VC (94.14%). In reducing ability test,SPK improved absorbance in reducing ability test system,and maximum absorbance was simi-lar to VC in concentration-dependant manner. CONCLUSIONS:SPK has obvious anti-oxidant activities in vitro.
8.The significance of designing callipers for insulin regulation and control of blood glucose in critical care patients
Jie HUANG ; Xiaoqin XU ; Xiangjun ZHU ; Jun XU ; Lijun CAO ; Weizhong CAO ; Huijie YU
Chinese Journal of Integrated Traditional and Western Medicine in Intensive and Critical Care 2017;24(2):198-199
10.An Analysis of Snoring Sound Pressure Level Parameters in Obstructive Sleep Apnea Hyperpnoea Syndrome Patients with Different Obstructive Site
Liu DING ; Huijie XU ; Hong CHEN ; Hao PENG ; Zhan GAO ; Weining HUANG
Journal of Audiology and Speech Pathology 2016;24(4):351-354
Objective To investigate the relationship between sound pressure level parameters of snoring sound and obstructive sites in patients with media or severe obstructive sleep apnea hypopnea syndrome(OSAHS). Methods Forty-six patients with media or severe OSAHS were included in this study.All underwent continuous upper airway pressure measurements and snoring sound pressure level recording simultaneously.The correlations between obstructive site,AHI,BMI and sound pressure level parameterssuch as equivalent continuous sound level (LAeq )and maximum sound pressure level (L10 )were analyzed.Results Both LAeq and L10 were affected only by AHI,whereas unrelated to obstructive site and BMI.Conclusion There is no definite relationship between the site of obstruction and sound pressure level parameters of snoring sound.It appears that LAeqand L10may be helpful to e-valuate the severity of OSAHS,but may have no clinical value on distinguishing obstructive sites.