1.Society of Critical Care Medicine 2024 Guidelines on Adult ICU Design: An Interpretation
Hui ZHANG ; Jianhua SUN ; Wanchen ZHAO ; Lingli XIE ; Cong MA ; Yifan FANG ; Jing CAI ; Na GUO
Medical Journal of Peking Union Medical College Hospital 2026;17(2):421-428
This article provides a systematic interpretation and review of the
2.Application Value of Vertebral CT Values in Fresh and Old Fractures Vertebral Bodies of Patients with Osteoporotic Vertebral Compression Fractures
Feng WANG ; Wei-sheng PENG ; Gui-liu CHEN ; Na DENG ; Xiao-bing HAN ; Hui-liang CAI ; Qiu-xiang CHEN
Progress in Modern Biomedicine 2025;25(19):3179-3185
Objective:To explore the value of using computed tomography(CT)values to distinguish fresh and old fractures vertebral bodies in osteoporotic vertebral compression fractures(OVCF).Methods:Retrospective analysis of clinical data of 101 OVCF patients in our hospital from September 2022 to September 2023.Kappa test for consistency between magnetic resonance imaging(MRI)and vertebral CT values in distinguished fresh or old OVCF.The difference of CT values between fresh,old fractures and adjacent normal vertebral bodies were compared.The diagnostic efficiency was analyed by receiver operating characteristic(ROC)curve.Results:There was a high consistency between vertebral CT values and MRI in the diagnosis of OVCF in fresh and old fractures(Kappa value=0.934).There was a difference in difference of CT values between adjacent normal vertebral bodies and fresh fractures vertebral bodies(P<0.05).There was a difference in difference of CT values of fresh fractures vertebral bodies and old fractures vertebral bodies(P<0.05).The ROC curve analysis results showed that,the combined measurement of CT values of fresh and old fractured vertebral bodies has an area under the curve(AUC)of 0.723,which was higher than alone measurement of the CT values of fresh fractured vertebral bodies and old fractured vertebral bodies of 0.536 and 0.610(Z=2.548,2.605,2.841,P<0.05).Conclusion:CT values of vertebral bodies show high consistency in distinguish fresh and old fractures of OVCF compared to MRI findings,and the diagnostic efficiency of combine detection is relatively high.
3.Diagnostic Value of Conventional CT Combined with Enhanced CT Scan in Bone Metastases
Feng WANG ; Gui-liu CHEN ; Wei-sheng PENG ; Na DENG ; Xiao-bing HAN ; Hui-liang CAI ; Qiu-xiang CHEN
Progress in Modern Biomedicine 2025;25(20):3337-3344
Objective:To explore the diagnostic value of conventional computed tomography(CT)combined with enhanced CT scan in bone metastases.Methods:This study was a retrospective observational study,84 suspected bone metastases patients admitted to our hospital from January 2022 to August 2024 were selected,All patients underwent conventional CT and enhanced CT scan and pathological examination,Using pathological examination results as the"gold standard"for diagnosis.The imaging manifestations of bone metastases using conventional CT combined with enhanced CT scan examination were observed;The detection rate and bone metastases types of conventional CT and enhanced CT scan were analyzed;The bone metastases location in different types of malignant tumors were analyzed;The detection results of bone metastases between conventional CT and enhanced CT scan were compared;the diagnostic efficacy of conventional CT and enhanced CT scan alone and in combination for bone metastases were analyzed by Receiver operating characteristic(ROC)curve.Results:The detection rate of osteogenic,osteolytic,cystic and mixed bone metastases by conventional CT combined with enhanced CT scan was supered to that of conventional CT and enhanced CT scan alone(P<0.05).Bone metastases from lung cancer,breast cancer and other tumors mainly occur in the spine,limbs and ribs,while esophageal cancer,gastric cancer,liver cancer,prostate cancer,thyroid cancer,renal cancer,and nasopharyngeal cancer had relatively fewer bone metastases.The positive detection cases of bone metastases used conventional CT combined with enhanced CT scan were supered to those used conventional CT and enhanced CT scan alone.The sensitivity,specificity and accuracy of conventional CT combined with enhanced CT scan for the diagnosis of bone metastases were 94.00%,94.11%and 94.04%,respectively,and the positive/negative predictive values were 95.91%and 91.42%,respectively.The sensitivity,specificity and accuracy of conventional CT scan were 84.00%,78.78%and 80.95%,respectively,and the positive/negative predictive values were 85.71%and 74.28%,respectively.The sensitivity,specificity and accuracy of enhanced CT were 89.79%,85.71%and 88.09%,respectively.and the positive and negative predictive values were 89.79%and 85.71%,respectively.The diagnostic efficacy of conventional CT combined with enhanced CT scan for bone metastases was significantly better than that of conventional CT and enhanced CT scan alone.Conclusions:Conventional CT combined with enhanced CT scan can significantly improve the diagnostic efficiency of bone metastases,and provide an important basis for clinical treatment.
4.Effects of Hot Night Exposure on Human Semen Quality: A Multicenter Population-Based Study.
Ting Ting DAI ; Ting XU ; Qi Ling WANG ; Hao Bo NI ; Chun Ying SONG ; Yu Shan LI ; Fu Ping LI ; Tian Qing MENG ; Hui Qiang SHENG ; Ling Xi WANG ; Xiao Yan CAI ; Li Na XIAO ; Xiao Lin YU ; Qing Hui ZENG ; Pi GUO ; Xin Zong ZHANG
Biomedical and Environmental Sciences 2025;38(2):178-193
OBJECTIVE:
To explore and quantify the association of hot night exposure during the sperm development period (0-90 lag days) with semen quality.
METHODS:
A total of 6,640 male sperm donors from 6 human sperm banks in China during 2014-2020 were recruited in this multicenter study. Two indices (i.e., hot night excess [HNE] and hot night duration [HND]) were used to estimate the heat intensity and duration during nighttime. Linear mixed models were used to examine the association between hot nights and semen quality parameters.
RESULTS:
The exposure-response relationship revealed that HNE and HND during 0-90 days before semen collection had a significantly inverse association with sperm motility. Specifically, a 1 °C increase in HNE was associated with decreased sperm progressive motility of 0.0090 (95% confidence interval [ CI]: -0.0147, -0.0033) and decreased total motility of 0.0094 (95% CI: -0.0160, -0.0029). HND was significantly associated with reduced sperm progressive motility and total motility of 0.0021 (95% CI: -0.0040, -0.0003) and 0.0023 (95% CI: -0.0043, -0.0002), respectively. Consistent results were observed at different temperature thresholds on hot nights.
CONCLUSION
Our findings highlight the need to mitigate nocturnal heat exposure during spermatogenesis to maintain optimal semen quality.
Humans
;
Male
;
Semen Analysis
;
Adult
;
Sperm Motility
;
Hot Temperature/adverse effects*
;
China
;
Middle Aged
;
Spermatozoa/physiology*
;
Young Adult
6.Application Value of Vertebral CT Values in Fresh and Old Fractures Vertebral Bodies of Patients with Osteoporotic Vertebral Compression Fractures
Feng WANG ; Wei-sheng PENG ; Gui-liu CHEN ; Na DENG ; Xiao-bing HAN ; Hui-liang CAI ; Qiu-xiang CHEN
Progress in Modern Biomedicine 2025;25(19):3179-3185
Objective:To explore the value of using computed tomography(CT)values to distinguish fresh and old fractures vertebral bodies in osteoporotic vertebral compression fractures(OVCF).Methods:Retrospective analysis of clinical data of 101 OVCF patients in our hospital from September 2022 to September 2023.Kappa test for consistency between magnetic resonance imaging(MRI)and vertebral CT values in distinguished fresh or old OVCF.The difference of CT values between fresh,old fractures and adjacent normal vertebral bodies were compared.The diagnostic efficiency was analyed by receiver operating characteristic(ROC)curve.Results:There was a high consistency between vertebral CT values and MRI in the diagnosis of OVCF in fresh and old fractures(Kappa value=0.934).There was a difference in difference of CT values between adjacent normal vertebral bodies and fresh fractures vertebral bodies(P<0.05).There was a difference in difference of CT values of fresh fractures vertebral bodies and old fractures vertebral bodies(P<0.05).The ROC curve analysis results showed that,the combined measurement of CT values of fresh and old fractured vertebral bodies has an area under the curve(AUC)of 0.723,which was higher than alone measurement of the CT values of fresh fractured vertebral bodies and old fractured vertebral bodies of 0.536 and 0.610(Z=2.548,2.605,2.841,P<0.05).Conclusion:CT values of vertebral bodies show high consistency in distinguish fresh and old fractures of OVCF compared to MRI findings,and the diagnostic efficiency of combine detection is relatively high.
7.Diagnostic Value of Conventional CT Combined with Enhanced CT Scan in Bone Metastases
Feng WANG ; Gui-liu CHEN ; Wei-sheng PENG ; Na DENG ; Xiao-bing HAN ; Hui-liang CAI ; Qiu-xiang CHEN
Progress in Modern Biomedicine 2025;25(20):3337-3344
Objective:To explore the diagnostic value of conventional computed tomography(CT)combined with enhanced CT scan in bone metastases.Methods:This study was a retrospective observational study,84 suspected bone metastases patients admitted to our hospital from January 2022 to August 2024 were selected,All patients underwent conventional CT and enhanced CT scan and pathological examination,Using pathological examination results as the"gold standard"for diagnosis.The imaging manifestations of bone metastases using conventional CT combined with enhanced CT scan examination were observed;The detection rate and bone metastases types of conventional CT and enhanced CT scan were analyzed;The bone metastases location in different types of malignant tumors were analyzed;The detection results of bone metastases between conventional CT and enhanced CT scan were compared;the diagnostic efficacy of conventional CT and enhanced CT scan alone and in combination for bone metastases were analyzed by Receiver operating characteristic(ROC)curve.Results:The detection rate of osteogenic,osteolytic,cystic and mixed bone metastases by conventional CT combined with enhanced CT scan was supered to that of conventional CT and enhanced CT scan alone(P<0.05).Bone metastases from lung cancer,breast cancer and other tumors mainly occur in the spine,limbs and ribs,while esophageal cancer,gastric cancer,liver cancer,prostate cancer,thyroid cancer,renal cancer,and nasopharyngeal cancer had relatively fewer bone metastases.The positive detection cases of bone metastases used conventional CT combined with enhanced CT scan were supered to those used conventional CT and enhanced CT scan alone.The sensitivity,specificity and accuracy of conventional CT combined with enhanced CT scan for the diagnosis of bone metastases were 94.00%,94.11%and 94.04%,respectively,and the positive/negative predictive values were 95.91%and 91.42%,respectively.The sensitivity,specificity and accuracy of conventional CT scan were 84.00%,78.78%and 80.95%,respectively,and the positive/negative predictive values were 85.71%and 74.28%,respectively.The sensitivity,specificity and accuracy of enhanced CT were 89.79%,85.71%and 88.09%,respectively.and the positive and negative predictive values were 89.79%and 85.71%,respectively.The diagnostic efficacy of conventional CT combined with enhanced CT scan for bone metastases was significantly better than that of conventional CT and enhanced CT scan alone.Conclusions:Conventional CT combined with enhanced CT scan can significantly improve the diagnostic efficiency of bone metastases,and provide an important basis for clinical treatment.
8. Lycium barbarian seed oil activates Nrf2/ARE pathway to reduce oxidative damage in testis of subacute aging rats
Rui-Ying TIAN ; Wen-Xin MA ; Zi-Yu LIU ; Hui-Ming MA ; Sha-Sha XING ; Na HU ; Chang LIU ; Biao MA ; Jia-Yang LI ; Hu-Jun LIU ; Chang-Cai BAI ; Dong-Mei CHEN
Chinese Pharmacological Bulletin 2024;40(3):490-498
Aim To explore the effects of Lycium berry seed oil on Nrf2/ARE pathway and oxidative damage in testis of subacute aging rats. Methods Fifty out of 60 male SD rats, aged 8 weeks, were subcutaneously injected with 125 mg • kg"D-galactosidase in the neck for 8 weeks to establish a subacute senescent rat model. The presence of senescent cells was observed using P-galactosidase ((3-gal), while testicular morphology was examined using HE staining. Serum levels of testosterone (testosterone, T), follicle-stimulating hormone ( follicle stimulating hormone, FSH ) , luteinizing hormone ( luteinizing hormone, LH ) , superoxide dis-mutase ( superoxide dismutase, SOD ) , glutathione ( glutathione, GSH) and malondialdehyde ( malondial-dehyde, MDA) were measured through ELISA, and the expressions of factors related to aging, oxidative damage, and the Nrf2/ARE pathway were assessed via immunohistochemical analysis and Western blotting. Results After successfully identifying the model, the morphology of the testis was improved and the intervention of Lycium seed oil led to a down-regulation in the expression of [3-gal and -yH2AX. The serum levels of SOD, GSH, T, and FSH increased while MDA and LH decreased (P 0. 05) . Additionally, there was an up-regulated expression of Nrf2, GCLC, NQOl, and SOD2 proteins in testicular tissue ( P 0. 05 ) and nuclear expression of Nrf2 in sertoli cells. Conclusion Lycium barbarum seed oil may reduce oxidative damage in testes of subacute senescent rats by activating the Nrf2/ARE signaling pathway.
9.Construction and Application of the Big Data Research Platform for Biological Sample Information Resources in a Large Com-prehensive Hospital
Hui LIU ; Hongwei CAI ; Juanjuan GAO ; Linpei ZHANG ; Tian NA ; Yawen WANG
Journal of Medical Informatics 2024;45(1):77-82
Purpose/Significance By integrating clinical and biological sample information,a big data research platform for biologi-cal sample information resources is built to provide one-stop data retrieval,integration and analysis services for researchers,and a data governance system is established,so as to improve the level of hospital clinical research infrastructure construction.Method/Process Common data model and data governance technology are adopted to integrate data sources from different vendors through extraction,trans-formation,loading and other steps to provide a unified data access portal.Result/Conclusion The big data research platform for biologi-cal sample information resources has the advantages of multi-dimensional data screening and rapid integrated analysis,which can pro-vide support for clinical research.
10.Bioequivalence test of metronidazole tablets in healthy human in China
Xiu-Qing PENG ; Cai-Hui GUO ; Ya-Li LIU ; Na ZHAO ; Hao-Jing SONG ; Wan-Jun BAI ; Zhan-Jun DONG
The Chinese Journal of Clinical Pharmacology 2024;40(13):1943-1947
Objective To evaluate the bioequivalence of metronidazole tablet and reference formulation in Chinese healthy subjects.Methods A single-dose,two-cycle,randomized,open,self-crossover trial was designed with 48 healthy subjects randomly assigned to fasting or postprandial group.For each group,a single oral dose of metronidazole tablet(200 mg)or a reference preparation(200 mg)per cycle were enrolled.The concentration of metronidazole in plasma was measured by high performance liquid chromatography tandem mass spectrometry(HPLC-MS/MS).The non-compartmental model was applied to calculate the pharmacokinetic parameters for bioequivalence analysis via SAS 9.3 software.Results The main pharmacokinetic parameters of test and reference metronidazole tablets in the fasting group were as follows,the Cmax were(4 855.00±1 383.97)and(4 799.13±1 195.32)ng·h·mL-1;the AUC0-t were(54 834.68±12 697.88)and(55 931.35±11 935.28)ng·h·mL-1;the AUC0-∞ were(56 778.09±13 937.76)and(57 922.83±13 260.54)ng·h·mL-1;the Tmax were respectively 1.17 and 1.00 h;t1/2 were(8.99±1.76)and(9.11±1.73)h,respectively.The ratio of the geometric mean and its 90%confidence intervals(CI)of Cmax,AUC0-t and AUC0-∞ were all within the equivalent interval of 80.00%-125.00%.As for postprandial conditions,the main pharmacokinetic parameters of test and reference metronidazole tablets were as follows,the Cmax were(4 057.08±655.08)and(4 044.17±773.98)ng·h·mL-1;the AUC0-t were(55 956.42±12 228.12)and(55 121.04±11 784.55)ng·h·mL-1;the AUC0-∞ were(58 212.83±13 820.00)and(57 350.38±13 229.46)ng·h·mL-1;the Tmax were 2.50 and 2.25 h;the t1/2 were(9.37±1.68)and(9.37±1.79)h,respectively.The ratio of the geometric mean and 90%CI of Cmax,AUC0-t and AUC0-∞ were all within the equivalent interval of 80.00%-125.00%.Conclusion The two preparations were bioequivalent to Chinese healthy adult volunteers under both fasting and fed conditions.

Result Analysis
Print
Save
E-mail