2.Repeatability of Ophtha TOP in measuring corneal parameters and its agreement with Pentacam
Shasha, YU ; Hui, SONG ; Xin, TANG
Chinese Journal of Experimental Ophthalmology 2016;34(12):1116-1120
Background Accurate measurement of corneal refractive parameters plays an important role in the diagnosis of eye diseases,design of refractive surgery and calculation of intraocular lens (IOL) power.Ophtha TOP is a new IOL calculator,so it is necessary to evaluate the repeatability and accuracy of Ophtha TOP in measuring corneal refractive parameters.Objective This study was to evaluate the repeatability of Ophtha TOP in measuring corneal refractive status in normal eyes and determine the agreement of the measuring outcomes between Ophtha TOP and Pentacam in pre-surgery cataract eyes.Methods A reliability evaluation method of diagnosis test was performed from September 2013 to October 2014.Sixty eyes of healthy volunteers aged (30.83 ±8.66) years old were examined in Tianjin Eye Hospital with Ophtha TOP for more than 5 times to evaluate the stability in measuring corneal refractive parameters.Corneal refractive parameters were measured by both Ophtha TOP and Pentacam for more than twice in 30 pre-surgery cataract eyes to assess the agreement with Pentacam.Keratometry and astigmatism parameters were recorded,including the flattest meridian (Kf),steepest meridian (Ks),mean keratometry (Km) and the astigmatism at J0 and J45.Intra-class correlation coefficients (ICC),repeatability (2.77Sw) and coefficient of variation (CoVs) were used to assess the stability of Ophtha TOP,and Bland-Altman graphs were adopted to value the consistency of measuring outcomes between Ophtha TOP and Pentacam.This study complied with Helsinki declaration,and written informed consent was obtained from each patient prior to any medical examination.Results The ICC of Ks,Kf,Km,J0 and J45 by Ophtha TOP were all ≥0.90,and 2.77Sw were all ≤0.36,The CoVs of Kf,Ks,Km by Ophtha TOP were all ≤0.30.The measuring values of Kf,Ks and Km were significantly higher in the Ophtha TOP than those in the Pentacam,with the mean differences (0.18±0.28) D,(0.24±0.29) D and (0.21± 0.26) D,respectively(t =3.48,4.50,4.49,all at P=0.00).The mean difference of the J0 was (0.07±0.21) D and that of the J45 was (-0.02±0.18)D between Ophtha TOP and Pentacam,showing insignificant differences between them (both at P>0.05).Bland-Altman graphs revealed that the 95% limit of agreement (LoA) of Kf,Ks and Km between the two methods was-0.37 D to 0.73 D,-0.33 D to 0.81 D and-0.30 D to 0.72 D,respectively,and that of J0 and J45 was-0.34 D to 0.48 D and-0.37 D to 0.33 D,respectively.Conclusions Ophtha TOP shows an excellent repeatability.Compared with Pentacam,Ophtha TOP presents a good consistence for measurement of the corneal astigmatism and moderate consistence for corneal curvature.
3.Effects of different temperature diet on weight, plasma glucose, plasma lipids and anti-oxidation in rats.
Hui XUE ; Zhi-xin TAN ; Yu-shan LI
Chinese Journal of Applied Physiology 2007;23(2):244-245
Animals
;
Blood Glucose
;
metabolism
;
Body Weight
;
Diet
;
Female
;
Lipids
;
blood
;
Male
;
Oxidation-Reduction
;
Rats
;
Rats, Wistar
;
Temperature
6.Effects of different temperature diets on glucose and lipid metabolism, sexual hormone and blood rheology in female rats.
Hui XUE ; Yu-shan LI ; Zhi-xin TAN
Chinese Journal of Applied Physiology 2009;25(2):201-267
Animals
;
Diet
;
Female
;
Follicle Stimulating Hormone
;
blood
;
Glucose
;
metabolism
;
Gonadal Steroid Hormones
;
blood
;
Hemorheology
;
Lipid Metabolism
;
physiology
;
Luteinizing Hormone
;
blood
;
Progesterone
;
blood
;
Rats
;
Rats, Wistar
;
Temperature
9.Quality control of statistical analysis in data management of clinical trials.
Xin-ji ZHANG ; Hao YU ; Zhao-hui WEI ; Jia HE
Acta Pharmaceutica Sinica 2015;50(11):1425-1427
Data is the basis and soul of clinical trials. To obtain accurate data, strict and standard data management is essential, which can be effectively supported by quality control in statistical analysis. In this paper, we briefly introduce the concept of the quality control in clinical trials, and describe its contents and methods. We hope that this work will be helpful to the application of statistical quality control in data management of clinical trials.
Clinical Trials as Topic
;
standards
;
Data Collection
;
standards
;
Quality Control
;
Statistics as Topic