1.Comparison between auditory steady-state response and 40 Hz auditory event related potential in the evaluation of hearing thresholds.
Xiao-Peng LI ; Wei WEI ; Jun WU ; Ji LÜ ; Hui-Ru SITU
Journal of Forensic Medicine 2009;25(4):263-266
OBJECTIVE:
To compare the results between auditory steady-state response (ASSR) and 40 Hz auditory event related potential (AERP), and explore the accuracy of hearing thresholds by using ASSR and AERP and the clinic forensic value.
METHODS:
Thirty seven ears were tested with pure-tone audiometer, 40Hz AERP and ASSR, respectively. All the volunteers in our study were awake during 40 Hz AERP test and ASSR test.
RESULTS:
Thresholds acquired with ASSR and 40Hz AERP test had a close correlativity and showed higher than those acquired with PTA test. There was no significant difference between the accuracy of ASSR and 40Hz AERP in estimating pure-tone thresholds.
CONCLUSION
After determining the correct value, ASSR can be used directly to evaluate hearing loss objectively.
Acoustic Stimulation
;
Adult
;
Audiometry, Evoked Response
;
Audiometry, Pure-Tone/methods*
;
Auditory Threshold
;
Evaluation Studies as Topic
;
Evoked Potentials, Auditory, Brain Stem/physiology*
;
Female
;
Hearing Loss, Sensorineural/physiopathology*
;
Humans
;
Male
;
Middle Aged
;
Predictive Value of Tests
;
Sleep/physiology*
;
Wakefulness
;
Young Adult