1.Aclinicalstudyontheefficacyandsafetyofmodifiedaspirationcatheterinthetreatment ofacutelowerextremitydeepveinthrombosis
Peng ZHANG ; Huhu REN ; Chen LI ; Kun YUE ; Jian CHEN ; Zhiqun WU ; Jun FENG
Journal of Practical Radiology 2019;35(7):1124-1127
Objective Toinvestigatethethrombusclinicalcurativeeffectandpracticalvalueintreatmentofdeepveinthrombosis (DVT)byusingmodifiedaspirationcatheter.Methods Atotalof35patientswhometthediagnosticcriteriaofDVTwererandomly assignedintoexperimentalandcontrolgroups.Afterasufficientpreoperativepreparation,thepatientsweredividedintotheexperimentalgroup (n=18,usingmodifiedaspirationcatheterwithsubsequenturokinasethrombolysisandconventionalanticoagulationtherapy)andthe controlgroup [n=17,usingthe8Fvascularsheaths (COOK,USA)duringtheprocedure,subsequenturokinasethrombolysisand conventionalanticoagulationtherapy].Thepatencyofvessels,theperimeterdifferenceandthecomplicationweredocumented.Theresultswere comparedbetweenthetwogroups.Results Inexperimentalgroup,thrombusremovalofgradeⅣ (removalratelessthan0%)was 0%in0case,gradeⅢ (removalratelessthan50%)was5.56%in1case,gradeⅡ (removalrategreaterthan50%)was94.44%in ncontrolgroup,thrombusremovalofgradeⅣwas23.53%in4cases,gradeⅢwas52.94%in9cases,gradeⅡwas23.53%in4cases. Thedifferencesofthelegcircumferenceoftheaffectedextremitiesat15cmaboveandbelowthekneejointattimeofdischargewere alllessthanthoseatadmission.Thedifferencesinbothpreoperativeandpostoperativedatabetweenthetwogroupswerestatistically significant(bothP<0.05).Noseriouscomplicationswerefoundintwogroups.Conclusion UsingmodifiedaspirationcathetertreatingDVTisa safeandeffectivemethod,whichhashighsuctionefficiencyandfewcomplications.Therefore,itisworthytoberecommended. 17casesI.
2.Development of a new laryngeal mask and its application in the implantation of tracheal stent
Shixin CHEN ; Xiaobing LI ; Peng ZHANG ; Jianwei CHEN ; Huhu REN ; Weidong GONG ; Zhiqun WU
Journal of Practical Radiology 2017;33(10):1597-1599
Objective To explore the clinical application of a new laryngeal mask in implantation of tracheal stent.Methods The new laryngeal masks were implanted under general anesthesia for 20 patients with tracheal or primary bronchus stenosis.The oxygen was continuously supplied from its side hole,and the stents were subsequently implanted from the tail hole.Results By using the new laryngeal masks under general anesthesia,all of 20 patients were successfully and leisurely implanted the tracheal stent.After the operation,the dyspnea symptoms were significantly improved,and there was no complication.Conclusion Stent implantation by using the new laryngeal mask under general anesthesia will provide a safe and effective treatment for tracheal stenosis.