1.The correlation between improvement of somatosensory-evoked potential and surgery effect of cervical spondylotic myelopathy
Zhuanghong CHEN ; Xianhua CAI ; Huasong WANG
Chinese Journal of Orthopaedics 1999;0(07):-
0.05). JOA scores of group A is higher than those of group B on 1, 2, 4 weeks postoperatively and the difference is of statistical significance (P
2.Effects of iptakalim hydrochloride on hypertensive cardiac remodeling
Chaoliang LONG ; Huasong FENG ; Hai WANG ;
Chinese Pharmacological Bulletin 1987;0(01):-
AIM To study the experimental therapeutic effects of iptakalim hydrochloride(Ipt) on hypertensive cardiac remodeling in spontaneously hypertensive rats(SHR) and stroke prone spontaneously hypertensive rats(SHRsp). METHODS SHR at the age of 12 week old were treated ig with lisinopril 12 mg?kg -1 ?d -1 or Ipt 3 mg?kg -1 ?d -1 , once a day for 30 days. Age matched Wistar rats were used as normal control. 10 week old SHRsp were treated ig with Ipt 0 25,1 0 and 4 0 mg?kg -1 , once a day for 12 weeks. Age matched Wistar rats were used as normal control. After killing animals, the effects of Ipt on hypertensive cardiac remodeling were investigated. RESULTS During the 4 week experimental period, the systolic blood pressure(SBP) and heart rates(HR) of the untreated SHR were increased progressively. Ipt 3 mg?kg -1 ?d -1 could decrease SBP effectively and inhibit the increasing tendency of HR. Ipt had no effects on hypertensive cardiac remodeling in SHR. Under the same experimental conditions, lisinopril 12 mg?kg -1 ?d -1 could decrease SBP effe-ctively and had no effects on HR. The hypertensive cardiac remodeling could be alleviated by lisinopril. During the 12 week experimental period, the SBP of the untreated SHRsp were increased progressively. Ipt 0 25,1 0 and 4 0 mg?kg -1 could decrease the SBP of SHRsp effectively. Ipt at the doses of 0 25 and 1 0 mg?kg -1 had no effects on heart rates. But in the 4th week after administration of Ipt 4 0 mg?kg -1 , significant decrease in heart rates was observed. Compared with Wistar rats, the weight of left ventricle and septum(LV+S) and the ratio of LV+S to body weight(LV+S/BW) in untreated SHRsp were elevated significantly. Ipt 0 25, 1 0 and 4 0 mg?kg -1 ?d -1 could decrease LV+S and LV+S/BW significantly. CONCLUSION Ipt could decrease SBP of SHR and SHRsp effectively. The effects of Ipt on hypertensive cardiac remodeling were related with the experimental therapeutic period. After having been treated with Ipt for 4 weeks, the hypertensive cardiac remodeling could not be reversed. But after having been treated with Ipt for 12 weeks, the hypertensive cardiac remodeling could be reversed significantly.
3.Treatment of comminuted fracture of proximal ulna with anatomical locking plate via posterior approach of elbow joint
Huasong WANG ; Junwei WANG ; Jifeng HUANG ; Gang WU ; Xianhua CAI
Chinese Journal of Orthopaedic Trauma 2016;18(1):79-82
Objective To evaluate the efficacy of anatomical locking titanium plate via the posterior elbow approach in the treatment of comminuted fractures of proximal ulna.Methods From January 2011 to December 2013,22 comminuted fractures of proximal ulna were treated by anatomical locking titanium plate via the posterior elbow approach.They were 14 men and 8 women,from 21 to 57 years of age (average,42.7 years).Nine cases were on the left side and 13 on the right.All were unilateral closed fractures.By the Schatzker classification,12 cases were type Ⅲ A,6 type Ⅲ C and 4 a combination of type Ⅲ A and type Ⅲ C.The Broberg & Morrey criteria were used to evaluate the elbow function one year postoperation.Results The follow-ups for the 22 cases ranged from 12 to 24 months (average,16 months).All the cases obtained clinical healing after 10 to 16 weeks (average,13 weeks).According to the Broberg & Morrey criteria,12 cases were evaluated as excellent,7 as good,and 3 as fair,yielding an excellent to good rate of 86.4%.No such complications as infection or necrosis of soft tissues,elbow stiffness,or obvious pain were observed during the follow-up period.Conclusion It is an effective treatment of comminuted fractures of proximal ulna with anatomical locking titanium plate through the posterior elbow approach.
4.Recurrence factors of spinal implant fixation for the treatment of lumbar disc herniation
Xiaoming CHEN ; Huasong MA ; Meng WANG ; Rong TAN ; Bin YANG
Chinese Journal of Tissue Engineering Research 2013;(30):5539-5544
BACKGROUND:The correct method selected according to the specific type and characteristics of lumbar disc herniation can achieve satisfactory effect, but in clinic, there stil some patients have recurrence symptoms after treatment. OBJECTIVE:To investigate the recurrence factors of spinal implant internal fixation for the treatment of lumbar disc herniation, as wel as the intervention measures. METHODS:Fifty-two patients with recurrence symptoms of lumbar disc herniation after internal fixation from January 2002 to December 2007 in the Department of Orthopedics, the 306th Hospital of PLA were retrospectively analyzed, including 28 male cases and 24 female cases, the average age was 43.2 years, ranged from 25-52 years. The time form first internal fixation to the recurrence was 3-192 months, average 38 months. The patients had the symptoms of lumbar and bilateral/unilateral leg pain and numbness. Al the patients underwent the anteroposterior radiographs of lumbar spine and the hyperextension and flexion lateral X-ray films to evaluate the stability of the lumbar spine. Lumbar magnetic resonance imaging was used to observe the intervertebral disc situation of the segment treated with lumbar internal fixation as wel as the spinal stenosis and disc degeneration. RESUTLS AND CONCLUSION:Among the 52 patients, 22 cases had recurrence lumbar disc herniation on the same segment after first internal fixation;four cases had recurrence symptoms caused by the spondylodiscitis after implant internal fixation;five cases had scar adhesions caused nerve compression on the site treated with internal fixation;10 cases had the symptoms of lateral recess and nerve root canal stenosis on the site treated with internal fixation;11 cases had recurrence symptoms caused by lumbar instability after internal fixation. It has reality clinical significance to analyze the reasons of recurrence of lumbar disc herniation after internal fixation
5.Effect of intraspinal grafting of adenovirus-mediated brain derived neurotrophic factor ex vivo transgene myoblasts cells and methylprednisolone on expression of caspase-3 after spinal cord injury
Qiang ZHANG ; Dewei ZOU ; Yong HAI ; Huasong MA ; Yongjun WANG
Chinese Journal of Trauma 2003;0(10):-
Objective To investigate the effect of intraspinal grafting of brain derived neurotrophic factor (BDNF) ex vivo transgene myoblasts cells and methylprednisolone on caspase-3 expression after spinal cord injury (SCI). Methods A total of 120 experimental rats were divided into Group A (spinal cord contusion injury group), Group B (grafting of BDNF ex vivo transgene myoblasts cells group), Group C (methylprednisolone intravenous injection group) and Group D (grafting of BDNF ex vivo transgene myoblasts cells and methylprednisolone intravenous injection group). At days 1, 3, 7, 14 and 28 respectively after SCI, the expression of caspase-3 was measured immunohistochemically for quantitative analysis via a computer image analysis system. The motion functional recovery of the rats was observed by praxiologic and electrophysiologic examination. Results Positive expression cells of caspase-3 were found in all groups, with number from the highest to the lowest in order of Group A, Group B, Group C and Group D (P
6.Influence of gamma globulin to serum B cell activating factor in therapy of neonatal thrombocytopenic purpura
Mei GAO ; Huasong ZENG ; Xinfang WANG ; Degen HE
International Journal of Pediatrics 2012;39(3):323-324,封3
Objective To study the influence of gamma globulin to serum B cell activating factor (BAFF) in therapy of neonatal thrombocytopenic purpura.Methods Fifteen cases with neonatal thrombocytopenic purpura(treatment group) were treated with gamma globulin.Serum BAFF levels of treatment group before and after treatment and 20 healthy neonates(control group) were tested.Results Serum BAFF level of the treatment group before treatment was(0.96±0.48) μg/L,which was statistically significant compared with that of the control group[(0.48 ±0.35) μg/L](P <0.05).Serum BAFF level of treatment group after treatment was (0.45 ± 0.37) μg/L,which was statistically significant compared with that of before treatment (P < 0.05),but was not statistically significant compared with that of the control group.Conclusion Gamma globulin can play a role in the therapy of neonatal thrombocytopenic purpura by reducing the BAFF.
7.Guidance to the Test Result Analysis Software of Medical College
Lang ZHUO ; Yibo WANG ; Zhenhuan XIE ; Meirong ZAHNG ; Huasong SHU
Chinese Journal of Medical Education Research 2003;0(03):-
Xuzhou Medical Collage developed a set of test result analysis software.It uses Visual Basic for Application(VBA)and statistics function in database Excel2000.It is simple to use and powerful in function.A brief introduction was given below to help you to use it.
8.Total knee arthroplasty:Goodness-of-fit analysis of intraoperative knee society score of Peking Union Medical College
Haiying JIA ; Ming LU ; Xiaoping WANG ; Rui ZHENG ; Jing ZHANG ; Huasong MA
Chinese Journal of Tissue Engineering Research 2013;(35):6228-6233
BACKGROUND:Knee society score of Peking Union Medical Col ege has been promoted and used in the 306th Hospital of PLA for 2 years and we have accumulated some clinical data.
OBJECTIVE:To analyze the stability and feasibility for suitable clinical medical practice of knee society score of Peking Union Medical Col ege.
METHODS:Fifty-five patients with osteoarthritis of the knee were included, and the patients were divided into
three groups:the preoperative group;3 months postoperative fol ow-up group;6 months postoperative fol ow-up group. The measurement results obtained by the application of the scale were compared to those of the Western Ontario and McMaster Universityies Ostroarthritis Index, visual analog scale, and hospital for special surgery
score, and then knee society score goodness-of-fit analysis was performed based on the structural equation model.
RESULTS AND CONCLUSION:Knee society score performance assessment of the signs and symptoms of
osteoarthritis of the knee patients was positively correlated with the pain severity of visual analog scale score;the overal knee society score of the patients after 6-month fol ow-up was significantly improved compared with that before treatment. The knee society score after 3-and 6-month fol ow-up was significantly higher than that before treatment, and the score was quite with the hospital for special surgery score. The overal assessment of the knee society score after treated for 3 and 6 months was improved for more than grade Ⅰ, the visual analog scale
score was decreased for more than 30%. The pain assessment items and physiological functional assessment items of Western Ontario and McMaster Universityies Ostroarthritis Index after 6-month fol ow-up were
significantly better than those before treatment (P<0.05);the visual analog scale score was poor after 3-month fol ow-up, and there was significant difference in visual analog scale score before and after treatment which was related with the pain level;the score accompanied by function and joint stiffness was significantly improved. The knee society score of Peking Union Medical Col ege obtained four dimensions of 22 assessment projects, and the
goodness-of-fit analysis showed that the scale had good goodness which had scientific nature and application value.
9.Anatomical measurements and clinical significance of anterior atlantoaxial transarticular screw fixation
Xianhua CAI ; Wenbing WAN ; Zhuanghong CHEN ; Jifeng HUANG ; Weibing HUANG ; Feng XU ; Ximing LIU ; Huasong WANG
Chinese Journal of Tissue Engineering Research 2009;13(13):2577-2581
BACKGROUND: Chinese anatomical parameters of antedor atlantoaxial transarticular screw fixation have been rarely reported although the technique is a novel method out of China for patients with C1-C2 instability. OBJECTIVE: To provide Chinese anatomical data for anterior C1-C2 transarticular screw fixation. DESIGN, TIME AND SETTING: A measurement experiment was performed at the Department of Anatomy, Southern Medical University and Department of Orthopedics, Wuhan General Hospital, Guangzhou Command of Chinese PLA between September 2006 and April 2008. MATERIALS: A total of 50 sets of dried Chinese adult human C1 and C2 specimens, without regard to gender and age, but no abnormality and breakage, were measured with an electronic digital caliper (precision 0.01 mm) and a goniometer(precision 0.5°) made in China. METHODS: One proper screw was drilled through the atlantoaxial joint respectively in the direction to middle part of laterosuperior angle in the posterior of C1 lateral mass, and the screw point should not break through the superior facet articularsurface of the C1. In the procedure, the screw drilling point was at the junction of the lateral border of C2 body to 4 mm above the inferior border of C2 anterior arch. border of transverse foramen of C2 body and the median line of C2 body, and the distance between the inserting point and the medial border of transverse foramen of C2 body. RESULTS: The data from all specimens were involved in the result analysis. In the sagittal plane, the minimum lateral angulation of the screw tract was (10.80±2.10)°(left) and (10.76±2.40)°(right) respectively, and the maximum lateral angulation was (25.13±3.12)°(left) and (25.12±2.86)°(right), respectively. In the coronal plane, the minimum posterior angulation was (8.85±2.12)° (left) and (9.28±2.65)° (right) respectively, and the maximum posterior angulation was (26.96±3.09)°(left) and (27.49±2.51)°(right), respectively. The left screw tract length was from (17.48±2.10) mm to (25.41±2.59) ram, and the right was from (17.49±2.23) mm to (25.58±2.42) mm. The left distance between the inserting point and the median line of C2 body was (9.84±0.69) mm, and the right was (9.81±0.66) mm. The left distance between the median line of C2 body and medial border of transverse foramen of C2 body was (14.12±1.28) mm, and the right was (14.60±1.36) mm. The left distance between the inserting point and medial border of transverse foramen of C2 body was (6.28±1.38) mm, and the right was (6.79±1.39) mm. CONCLUSION: It is optimal for the anterior C1-C2 transarticular screw fixation to place the antedor screw with a length of 17 to 25 mm in lateral angulation ranging from 10° to 25° and the posterior angulation ranging from 9° to 27°. During the procedure, the dissecting distance from the middle of C2 body to lateral should not exceed 14 mm.
10.Thrombosis prediction within short time after total knee arthroplasty: dynamic monitoring of D-Dimer and fibrin degradation products
Wei YUAN ; Huasong MA ; Xiaoping WANG ; Zhiming CHEN ; Ming LU ; Qiming XU ; Dongyun REN
Chinese Journal of Tissue Engineering Research 2015;19(17):2661-2666
BACKGROUND:Deep vein thrombosis after total knee arthroplasty has attracted increasing attention in recent years,but how to detect deep vein thrombosis in the early time in clinical practice remains unclear.Whether it is necessary to perform type-B ultrasonic or other invasive examination in lower limbs has become a hot issue.OBJECTIVE:To explore the significance of D-Dimer and fibrin degradation products in the prediction of deep vein thrombosis after total knee arthroplasty.METHODS:56 patients received total knee arthroplasty were colected from Department of Orthopedics,The 306th Hospital of Chinese PLA,between December 2012 and February 2014.The D-Dimer and fibrin degradation products were dynamicaly monitored before operation and at 1,3,5,7,10 days post-operation.Al the patients received type-B ultrasonic examination in double lower limbs at 10 days post-operation,and divided into thrombus group and non-thrombus group.The D-Dimer and fibrin degradation products in the two groups were compared.RESULTS AND CONCLUSION:Deep vein thrombosis was found in 13 cases by ultrasonic-B postoperation,D-Dimer and fibrin degradation products showed no significant difference between the two groups at 1 week after operation (P>0.05),but the difference was significant at 10 days (P<0.01).D-Dimer and fibrin degradation products index should be monitored dynamicaly for at least 10 days after operation,which is helpful for the earlydiagnosis of thrombosis.