1.Development and application of fixed ruler for simulated locator
Guohua LU ; Huankun WANG ; Ke LI
Chinese Medical Equipment Journal 2017;38(4):48-50
Objective To develop a fixed ruler for the simulated locator to measure the distance between human organs.Methods Analyses were carried out on the problems of the existing measures of the simulated locator and clinical requirements,and then the matching of the ruler with the locator and etc were explored.The structures of the fixing hole and slots were determined,and the ruler base was selected.The ruler was composed of an organic glass plate with multi slots and multi cylindrical copper wires.Results At the isocenter of the locator,the fixed scale values of the ruler equaled to those of the ruler on the screen,and the values for multi point distances could be obtained with the fixed ruler and stored in medical image.Conclusion The fixed ruler measures the distance between human organs simply and accurately,and lays a foundation for the development of likely product.
2.Effects of overexpression of miR-30b on the biological function and tumor formation of human gastric cancer cells
Cuicui CHEN ; Huankun LIANG ; Kangyan LI ; Chengwu CHENG ; Xipan LIU ; Jiexing LI ; Shuhai ZHONG ; Licheng ZHANG ; Laiqing LI
Tianjin Medical Journal 2017;45(7):677-681
Objective To investigate the effect of overexpression of miR-30b on the proliferation,cell cycle,apoptosis and invasion of gastric cancer cell line SGC-7901 and AGS,and the inhibitory effect on the tumor formation in vivo.Methods SGC-7901 and AGS cells were transfected with miR-30b mimics and miR-control,and qRT-PCR was used to detect the expression levels of miR-30b.Western blot assay was used to detect the expression of eIFSA2 protein.CCK-8 assay was used to measure the cell proliferation.Flow cytometry was used to analyze cell cycle and apoptosis.Transwell assay was used to detect cell invasion.In addition,the SGC-7901 and AGS cells transfected with miR-30b mimics and miR-control were injected into nude mice to observe the tumor formation and the expression of eIFSA2 protein in vivo.Results Results of qRT-PCR showed that the relative expression of miR-30b was significantly higher than that of miR-control group (P < 0.05).Western blot assay showed that the expression of eIF5A2 protein was decreased in miR-30b mimics group.CCK-8 assay showed that cell proliferation was inhibited in miR-30b mimics group.The result of flow cytometry showed that the cell cycle decreased and the apoptosis increased in miR-30b group.Transwell assay showed that the cell invasion was significantly lower in miR-30b group than that of control group (P < 0.05).Overexpression of miR-30b inhibited the formation of tumor and decreased the expression of eIF5A2 protein in vivo.Conclusion Overexpression of miR-30b inhibits the proliferation,invasion and tumor formation of gastric cancer cells,and reduces the expression of eIF5A2 protein,which provides a potential target for gastric cancer treatment.
3.Development and effectiveness evaluation of time-resolved fluoroimmunoas-say kit for detection of Schistosoma japonicum
Qingdong MENG ; Yan WANG ; Wenqiao SUN ; Shoulei REN ; Bo XIN ; Pengfei ZHU ; Kangyan LI ; Huankun LIANG ; Licheng ZHANG
Chinese Journal of Schistosomiasis Control 2017;29(1):64-67
Objective To develop a kit of time?resolved fluoroimmunoassay(TRFIA)for detection of Schistosoma japonicum protein SjP38,and evaluate its effectiveness. Methods The anti 9G7 SjP38 monoclonal antibody was used as the capture anti?body coated with 96?hole plate,and the Eu3+labeled 1A6 monoclonal antibody was used as the detection antibody to establish the TRFIA SjP38 kit. In addition,the accuracy,sensitivity,precision,stability and coincidence rate to pathogenic diagnosis of the kit were evaluated. Results This established kit possessed high accuracy,wide linear range from 2 to 1 250 ng/ml,high sensitivity with the minimum detectable concentration of 0.14 ng/ml,and good precision(the coefficient variation of the intra?and inter?assay were 3.6%to 4.6%and 5.1%to 6.7%,respectively). The stability tests showed that the reagents could be stable for six months at 4℃,7 d at 37℃. The positive and negative corresponding rates to the pathogen detection method were 95%and 100%respectively. Conclusion All the performance and detection indicators of the kit have reached the requirements of clinical test,but its clinical application still needs further validation.
4.Comparison of modified double-reverse traction and traditional open reduction in the treatment of tibial plateau fractures
Huankun LI ; Yanhong LI ; Dongjie HUANG ; Baijun HU ; Dawei GAO ; Yufeng WU ; Jianbang TANG ; Hongjun CHEN ; Lili SANG
Chinese Journal of Orthopaedic Trauma 2024;26(2):118-124
Objective:To compare the curative effects between modified double-reverse traction technique and traditional open reduction in the treatment of tibial plateau fractures.Methods:A retrospective study was conducted to analyze the data of 70 patients with Schatzker type Ⅳ-Ⅴ tibial plateau fracture who had undergone surgical treatment at The Third Department of Orthopaedics, Zhongshan Hospital of Traditional Chinese Medicine Affiliated to Guangzhou University of Traditional Chinese Medicine from January 2017 to December 2022. The patients were divided into an observation group treated with modified double-reverse traction and a control group treated with traditional open reduction. In the observation group of 37 cases, there were 20 males and 17 females with an age of (44.6±13.5) years, and 9 cases of type Ⅳ and 28 cases of type V by the Schatzker classification; in the control group of 33 cases, there were 18 males and 15 females with an age of (45.9±13.7) years, and 10 cases of type Ⅳ and 23 cases of type Ⅴ by the Schatzker classification. The 2 groups were compared in terms of operation time, length of main incision, intraoperative blood loss, Rasmussen imaging score before discharge, and knee function score of American Hospital for Special Surgery (HSS), Visual Analogue Scale (VAS), fracture healing and complications at 6 months postoperatively.Results:There was no significant difference in the preoperative general data between the 2 groups, showing group comparability ( P>0.05). All patients were followed up for (14.3±1.4) months. The observation group was significantly better than the control group in operation time [(113.9±11.4) min versus (151.82±10.37) min], length of main incision [4 (4, 5) cm versus 6 (6, 7) cm], intraoperative blood loss [30 (20, 35) mL versus 55 (50, 65) mL], VAS [0 (0, 0) point versus 0 (0, 1) points] and HSS score [(89.8±3.1) points versus (86.0±3.5) points] ( P<0.05). There were no significant differences between the 2 groups in Rasmussen imaging score before discharge, or fracture healing rate or complication rate at 6 months postoperatively ( P>0.05). Conclusion:In the treatment of Schatzker type Ⅳ-Ⅴ tibial plateau fractures, modified double-reverse traction technique is worthy of clinical application and promotion, because it is advantageous over traditional open reduction in terms of shorter operation time, smaller surgical incision, less intraoperative blood loss, less postoperative pain and better knee function.
5.Treatment of tibial plateau fractures using modified double reverse traction technique
Hongjun CHEN ; Baijun HU ; Dawei GAO ; Yufeng WU ; Huahui LIANG ; Fukai GAN ; Huankun LI ; Gang QIN
Chinese Journal of Orthopaedic Trauma 2023;25(4):351-355
Objective:To study the clinical efficacy of our modified double reverse traction technique in the treatment of tibial plateau fractures.Methods:A retrospective study was conducted of the 66 patients with tibial plateau fracture who had been treated by our modified double reverse traction technique at Articular Department, Zhongshan Hospital of Traditional Chinese Medicine from March 2019 to December 2021. There were 37 males and 29 females, with an age of (44±14) years. The double reverse traction technique was used in all patients for reduction of the tibial plateau fracture, and their collapsed articular surfaces were restored by our self-designed universal high affinity prying technique, or by fibular graft support, or by the hooping technique to restore the transverse diameter of the tibial plateau which had been widened. The outcomes of fracture reduction at 2 days postoperation were recorded and evaluated by Rasmussen imaging assessment. Complications were also recorded. The visual analog scale (VAS) pain scores and Hospital for Special Surgery (HSS) scores were compared between preoperation, 3 and 6 months postoperation and the rates of fracture healing between 3 and 6 months postoperation.Results:This group of 66 patients was followed up for 12.0(8.0, 16.5) months. The Rasmussen imaging assessment at 2 days postoperation: 60 excellent, 4 good, and 2 fair cases, yielding an excellent to good rate of 97.0% (64/66). At 3 and 6 months postoperation, the VAS scores [1 (0, 1) and 0 (0, 1)] and HSS scores [84 (78, 88) and 91 (85, 95)] were significantly improved compared with those before operation [4 (3, 5) and 36 (29, 39)], and the values at 6 months postoperation were significantly improved compared with those at 3 months postoperation ( P<0.05). The rate of clinical fracture healing at 6 months postoperation (100%, 66/66) was significantly higher than that at 3 months postoperation (77.3%, 51/66) ( P<0.05). Perioperatively, no adverse events were observed like incision infection, deep vein thrombosis of lower limbs, or failure or exposure of internal fixation, except for delayed incision healing in only one patient. Conclusion:In the minimally invasive surgery for tibial plateau fractures, our modified double reverse traction technique can result in excellent fracture reduction by imaging assessment, fine functional recovery of the knee joint and relief of pain.