1.Diagnostic value of spectral CT imaging on complications after breast augmentations with siliconeim plants
Huanguo LI ; Qun LAO ; Kaiyu ZHAO ; Rui WANG ; Dong HE
Chinese Journal of Medical Aesthetics and Cosmetology 2016;22(6):362-364
Objective To evaluate the diagnostic value of the spectral CT imaging on the complications after breast augmentations with silicone implants.Methods A lot of 22 cases with breast implants were scanned by the Gemstone spectral imaging (GSI) CT.The original data were loaded in processed workstation, analyzed by GSI analysis software, and then stored the series we needed.The features of the complications after breast augmentations with silicone implants were reviewed retrospectively on the spectral CT images.Results A lot of 44 breast implants scanned in our study and there were 23 breast implants with complications, including 7 breast implants with capsular rupture (6 breast implants with endometrial rupture detected by spectral CT, including 4 breast implants with endometrial rupture, 3 breast implants with outer membrane rupture and leakage), 13 breast implants with capsular contracture (classification according to Baker's classification, 6 in grade Ⅰand 7 in grade Ⅱ), 8 breast implants were moved and 2 breasts had foci of calcification.Conclusions The spectral CT imaging play important role in detecting the complications after breast augmentations with silicone implants by GSI analysis software.
2.Diagnostic value of artificial intelligence based on lung CT for benign and malignant pulmonary nodules
Dankun ZHANG ; Feng CUI ; Yongsheng ZHANG ; Liang DU ; Huanguo LI ; Caiyong ZHAO ; Zhiping LI
China Modern Doctor 2024;62(23):44-47
Objective To explore the value of artificial intelligence(AI)in the diagnosis of pulmonary nodules in terms of consistency and efficiency compared with two radiologists(physician 1 is a chief physician and physician 2 is a deputy chief physician)in the diagnosis of benign and malignant pulmonary nodules using computed tomography(CT).Methods Retrospective analysis of 201 patients with pulmonary nodules confirmed by surgery pathology at Hangzhou Municipal Hospital affiliated to Zhejiang Chinese Medical University from January 2021 to October 2022,including a total of 229 pulmonary nodules,of which 74 were benign and 155 were malignant.The consistency of AI diagnosis with two radiologists was evaluated by weighted Kappa test,and the diagnostic performance of AI with the two radiologists was evaluated by the receiver operating characteristic curve(ROC).Results In the diagnosis of the benign and malignant nature of partial solid nodules,ground-glass nodules,solid nodules,and partial ground-glass and solid plus ground-glass nodules,the consistency between AI and physician 2 was higher than that between AI and physician 1.Additionally,the area under the curve(AUC)of physician 2 was higher than that of AI and physician 1 with statistically significant differences between the AUCs of ground-glass nodules,solid nodules,and partial ground-glass and solid plus ground-glass nodules(P<0.05).In the diagnosis of the benign and malignant nature of partial solid nodules and ground-glass nodules,the AUC of physician 1 was higher than that of AI,but there was no statistically significant difference between the two(P>0.05).In the diagnosis of the benign and malignant nature of solid nodules and partial ground-glass and solid plus ground-glass nodules,the AUC of AI was higher than that of physician 1 with statistically significant differences between the two(P<0.05).In the diagnosis of the benign and malignant nature of ground-glass nodules,solid nodules,and partial ground-glass and solid plus ground-glass nodules,AI's sensitivity(97%,92%,and 94%)was higher than that of physician 1(58%,89%,and 72%)and physician 2(83%,84%,and 85%).Conclusion AI has a certain diagnostic efficacy in the diagnosis of pulmonary nodules malignancy.The overall diagnostic efficacy of the AI system used in this study is between that of physician 1 and physician 2,but its sensitivity is higher than that of the latter two.