1.Generation of differentiated osteoblast specific fgfr1 knockout mice
Fubing LI ; Ling ZHAO ; Xiumin LU ; Ying YU ; Qifen HE ; Maomao CHEN ; Yaqi DUAN ; Huabing QI ; Lin CHEN
Journal of Third Military Medical University 1983;0(04):-
Objective To obtain differentiated osteoblast-specific inactivation of fgfr1 mice Methods To obtain fgfr1△/+/OC-CreTG/+ mice,fgfr1flox/flox mice obtained from NIH were crossed with OC-Cre mice To obtain fgfr1△/△/OC-CreTG/+ mutant mice,fgfr1△/+/OC-CreTG/+ further crossed with themselves or fgfr1flox/flox mice After fgfr1△/△/OC-CreTG/+ crossed with fgfr1flox/flox mice,half of their offspring were mutant mice Results Differentiated osteoblast-specific fgfr1 knockout mice were obtained Conclusion fgfr1△/△/OC-CreTG/+ mice were obtained through proper crossing strategy,which provides a suitable platform for studying fgfr1 function in bone development and fracture healing
2.Syndrome of Inappropriate Antidiuresis-report of 40 cases
Lingling XU ; Feng GU ; Mei LI ; Yong FU ; Huabing ZHANG ; Wei LI ; Lin LU ; Xin YUE ; Mingming HU ; Yan JIANG ; Huijuan ZHU ; Ou WANG ; Naishi LI ; Jiangfeng MAO ; Jianping XU ; Lian DUAN ; Shi CHEN ; Ting ZHOU
Chinese Journal of Practical Internal Medicine 2000;0(11):-
Objective We have summarized the clinical characteristics of inappropriate antidiuresis(SIAD).Methods We adopted retrospective analysis to analyze the clinical and lab data of 40 cases.Results The most common causes of SIAD were malignant tumor,lung disease,and central nervous system disease.The five major abnormal lab data were:hypochloraemia,hypouricemia,hyponitremia,hypocalcemia,and low hematocrit.Conclusion It is important to diagnose SIAD as soon as possible,and patient presented hyponatremia combined with hypouricemia must be suspected to have SIAD.
3.Geometric Shape Validation of Knee Statistical Shape Model
Huabing DUAN ; Xuelian GU ; Xiaohu LI ; Jincheng ZHOU ; Yihao CHANG ; Jie WANG ; Xiaochen GUO
Journal of Medical Biomechanics 2024;39(2):243-249
Objective To obtain the range of anatomical parameters of healthy knee joints in Chinese males and validate a statistical shape model(SSM)based on the geometric shape of a healthy knee to provide references for the design of knee SSM-based prostheses.Methods Computed tomography(CT)images of knee joints from 112 healthy males were acquired to build three-dimensional(3D)knee joint models.Each model was the target model separately,and the remaining models were used as the training set for principal component analysis(PCA).The obtained knee SSM was fitted to the target model to predict the SSM.The exact anatomical measurement points were marked on the sample and SSM prediction models,and 17 linear and 3 angular parameters were derived.The values of the anatomical parameters were statistically tested using an independent samples t-test and Mann-Whitney U-test,and the validity of the SSM in terms of geometric shape was demonstrated if the resulting P-values were all greater than 0.05.Results Qualitative and quantitative comparative analyses of anatomical parameters showed that the mean deviation of linear parameters was less than 6 mm,and that of angular parameters was less than 2.5°.The results of statistical tests showed P>0.05 for all anatomical parameters,proving that the knee SSM prediction model was not statistically different from the true healthy model in terms of geometric shape.Conclusions This study derived a reference range of anatomical parameters for a healthy knee and demonstrated that the knee SSM model was consistent with the real healthy model in terms of shape.The results provide a reference for the design of knee SSM-based prostheses.