1.Psychometric Testing of Behavior Assessment for Children.
Hsiao Ling CHUANG ; Ching Pyng KUO ; Chia Ying LI ; Wen Chun LIAO
Asian Nursing Research 2016;10(1):39-44
PURPOSE: The purpose of this study was to test the reliability and validity of the Behavior Assessment for Children (BAC) in a community of school-aged children in Taiwan. METHOD: A school-based sample comprising third grade and fourth grade students was recruited from Taichung City in Taiwan. The parents (n = 248) and teachers (n = 15) of these students completed structured questionnaires, including the Child Behavior Checklist (CBCL) and the proposed BAC. Content validity, concurrent validity, construct validity, internal consistency, and inter-rater reliability of the BAC were assessed. RESULTS: The BAC comprised three subscales (attention, emotion, and self-control) that included 17 items. The content validity index (CVI) score was 0.98. The result of the confirmatory factor analysis (goodness of fit = .90, root mean square of residual = .03, root mean square error of approximation = .06, and comparative fit index = .94) supported the construct validity of the three BAC subscales. The concurrent validity of the BAC subscales significantly correlated with the compatible CBCL subscales (r = .59-.78, p < .001). Cronbach α of the subscales of the BAC ranged from .78 to .92. The intraclass correlation coefficient between the parents and teachers ranged from .31 to .44, and the joint probability of agreement ranged from 31.4% to 92.2%. CONCLUSIONS: The BAC is a valid and reliable instrument for evaluating behavioral problems in schoolaged children.
*Attention
;
Child
;
Child Behavior Disorders/*diagnosis
;
*Diagnostic Techniques and Procedures
;
*Emotions
;
Female
;
Humans
;
Male
;
*Psychometrics
;
Reproducibility of Results
;
*Self-Control
;
Taiwan
2.Differentiation of the Infarct Core from Ischemic Penumbra within the First 4.5 Hours, Using Diffusion Tensor Imaging-Derived Metrics: A Rat Model.
Duen Pang KUO ; Chia Feng LU ; Michelle LIOU ; Yung Chieh CHEN ; Hsiao Wen CHUNG ; Cheng Yu CHEN
Korean Journal of Radiology 2017;18(2):269-278
OBJECTIVE: To investigate whether the diffusion tensor imaging-derived metrics are capable of differentiating the ischemic penumbra (IP) from the infarct core (IC), and determining stroke onset within the first 4.5 hours. MATERIALS AND METHODS: All procedures were approved by the local animal care committee. Eight of the eleven rats having permanent middle cerebral artery occlusion were included for analyses. Using a 7 tesla magnetic resonance system, the relative cerebral blood flow and apparent diffusion coefficient maps were generated to define IP and IC, half hour after surgery and then every hour, up to 6.5 hours. Relative fractional anisotropy, pure anisotropy (rq) and diffusion magnitude (rL) maps were obtained. One-way analysis of variance, receiver operating characteristic curve and nonlinear regression analyses were performed. RESULTS: The evolutions of tensor metrics were different in ischemic regions (IC and IP) and topographic subtypes (cortical, subcortical gray matter, and white matter). The rL had a significant drop of 40% at 0.5 hour, and remained stagnant up to 6.5 hours. Significant differences (p < 0.05) in rL values were found between IP, IC, and normal tissue for all topographic subtypes. Optimal rL threshold in discriminating IP from IC was about -29%. The evolution of rq showed an exponential decrease in cortical IC, from -26.9% to -47.6%; an rq reduction smaller than 44.6% can be used to predict an acute stroke onset in less than 4.5 hours. CONCLUSION: Diffusion tensor metrics may potentially help discriminate IP from IC and determine the acute stroke age within the therapeutic time window.
Animal Care Committees
;
Animals
;
Anisotropy
;
Cerebrovascular Circulation
;
Diffusion Tensor Imaging
;
Diffusion*
;
Gray Matter
;
Infarction, Middle Cerebral Artery
;
Models, Animal*
;
Rats*
;
ROC Curve
;
Stroke
3.The Influence of Reconstruction Algorithm and Heart Rate on Coronary Artery Image Quality and Stenosis Detection at 64-Detector Cardiac CT.
Yi Ting WANG ; Chung Yi YANG ; Jong Kai HSIAO ; Hon Man LIU ; Wen Jen LEE ; Yun SHEN
Korean Journal of Radiology 2009;10(3):227-234
OBJECTIVE: We wanted to evaluate the impact of two reconstruction algorithms (halfscan and multisector) on the image quality and the accuracy of measuring the severity of coronary stenoses by using a pulsating cardiac phantom with different heart rates (HRs). MATERIALS AND METHODS: Simulated coronary arteries with different stenotic severities (25, 50, 75%) and different luminal diameters (3, 4, 5 mm) were scanned with a fixed pitch of 0.16 and a 0.35 second gantry rotation time on a 64-slice multidetector CT. Both reconstruction algorithms (halfscan and multisector) were applied to HRs of 40-120 beats per minute (bpm) at 10 bpm intervals. Three experienced radiologists visually assessed the image quality and they manually measured the stenotic severity. RESULTS: Fewer measurement errors occurred with multisector reconstruction (p = 0.05), a slower HR (p < 0.001) and a larger luminal diameter (p = 0.014); measurement errors were not related with the observers or the stenotic severity. There was no significant difference in measurements as for the reconstruction algorithms below an HR of 70 bpm. More nonassessable segments were visualized with halfscan reconstruction (p = 0.004) and higher HRs (p < 0.001). Halfscan reconstruction had better quality scores when the HR was below 60 bpm, while multisector reconstruction had better quality scores when the HR was above 90 bpm. For the HRs between 60 and 90 bpm, both reconstruction modes had similar quality scores. With excluding the nonassessable segments, both reconstruction algorithms achieved a similar mean measured stenotic severity and similar standard deviations. CONCLUSION: At a higher HR (above 90 bpm), multisector reconstruction had better temporal resolution, fewer nonassessable segments, better quality scores and better accuracy of measuring the stenotic severity in this phantom study.
*Algorithms
;
Artifacts
;
Computer Simulation
;
Coronary Angiography/*methods
;
Coronary Stenosis/*radiography
;
Electrocardiography
;
*Heart Rate
;
Image Processing, Computer-Assisted/*methods
;
Models, Cardiovascular
;
Observer Variation
;
Phantoms, Imaging
;
Reproducibility of Results
;
Severity of Illness Index
;
Tomography, Spiral Computed/*methods
4.Diffusion Tensor-Derived Properties of Benign Oligemia, True “at Risk” Penumbra, and Infarct Core during the First Three Hours of Stroke Onset: A Rat Model.
Fang Ying CHIU ; Duen Pang KUO ; Yung Chieh CHEN ; Yu Chieh KAO ; Hsiao Wen CHUNG ; Cheng Yu CHEN
Korean Journal of Radiology 2018;19(6):1161-1171
OBJECTIVE: The aim of this study was to investigate diffusion tensor (DT) imaging-derived properties of benign oligemia, true “at risk” penumbra (TP), and the infarct core (IC) during the first 3 hours of stroke onset. MATERIALS AND METHODS: The study was approved by the local animal care and use committee. DT imaging data were obtained from 14 rats after permanent middle cerebral artery occlusion (pMCAO) using a 7T magnetic resonance scanner (Bruker) in room air. Relative cerebral blood flow and apparent diffusion coefficient (ADC) maps were generated to define oligemia, TP, IC, and normal tissue (NT) every 30 minutes up to 3 hours. Relative fractional anisotropy (rFA), pure anisotropy (rq), diffusion magnitude (rL), ADC (rADC), axial diffusivity (rAD), and radial diffusivity (rRD) values were derived by comparison with the contralateral normal brain. RESULTS: The mean volume of oligemia was 24.7 ± 14.1 mm³, that of TP was 81.3 ± 62.6 mm³, and that of IC was 123.0 ± 85.2 mm³ at 30 minutes after pMCAO. rFA showed an initial paradoxical 10% increase in IC and TP, and declined afterward. The rq, rL, rADC, rAD, and rRD showed an initial discrepant decrease in IC (from −24% to −36%) as compared with TP (from −7% to −13%). Significant differences (p < 0.05) in metrics, except rFA, were found between tissue subtypes in the first 2.5 hours. The rq demonstrated the best overall performance in discriminating TP from IC (accuracy = 92.6%, area under curve = 0.93) and the optimal cutoff value was −33.90%. The metric values for oligemia and NT remained similar at all time points. CONCLUSION: Benign oligemia is small and remains microstructurally normal under pMCAO. TP and IC show a distinct evolution of DT-derived properties within the first 3 hours of stroke onset, and are thus potentially useful in predicting the fate of ischemic brain.
Animals
;
Anisotropy
;
Area Under Curve
;
Brain
;
Cerebrovascular Circulation
;
Diffusion Tensor Imaging
;
Diffusion*
;
Infarction, Middle Cerebral Artery
;
Models, Animal*
;
Rats*
;
Stroke*
5.Proton Pump Inhibitor-unresponsive Laryngeal Symptoms Are Associated With Psychological Comorbidities and Sleep Disturbance: A Manometry and Impedance-pH Monitoring Study
Wen-Hsuan TSENG ; Wei-Chung HSU ; Tsung-Lin YANG ; Tzu-Yu HSIAO ; Jia-Feng WU ; Hui-Chuan LEE ; Hsiu-Po WANG ; Ming-Shiang WU ; Ping-Huei TSENG
Journal of Neurogastroenterology and Motility 2023;29(3):314-325
Background/Aims:
Laryngeal symptoms are largely treated with empiric proton pump inhibitor (PPI) therapy if no apparent pathology shown on ear, nose, and throat evaluation and reflux-related etiologies are suspected. However, treatment response remains unsatisfactory. This study aimed to investigate the clinical and physiological characteristics of patients with PPI-refractory laryngeal symptoms.
Methods:
Patients with persistent laryngeal symptoms despite PPI treatment for ≥ 8 weeks were recruited. A multidisciplinary evaluationcomprising validated questionnaires for laryngeal symptoms (reflux symptom index [RSI]), gastroesophageal reflux disease symptoms, psychological comorbidity (5-item brief symptom rating scale [BSRS-5]) and sleep disturbance (Pittsburgh sleep quality index [PSQI]), esophagogastroduodenoscopy, ambulatory impedance-pH monitoring, and high-resolution impedance manometry were performed.Healthy asymptomatic individuals were also recruited for comparison of psychological morbidity and sleep disturbances.
Results:
Ninety-seven adult patients and 48 healthy volunteers were analyzed. The patients had markedly higher prevalence of psychological distress (52.6% vs 2.1%, P < 0.001) and sleep disturbance (82.5% vs 37.5%, P < 0.001) than the healthy volunteers. There were significant correlations between RSI and BSRS-5 scores, and between RSI and PSQI scores (r = 0.26, P = 0.010, and r = 0.29, P = 0.004, respectively). Fifty-eight patients had concurrent gastroesophageal reflux disease symptoms. They had more prominent sleep disturbances (89.7% vs 71.8%, P < 0.001) than those with laryngeal symptoms alone but similar reflux profiles and esophageal motility.
Conclusions
PPI-refractory laryngeal symptoms are mostly associated with psychological comorbidities and sleep disturbances. Recognition of these psychosocial comorbidities may help optimize management in these patients.