Objective To discuss the liver function recovery affected by the portal vein flow in patients who underwent adult-to-adult living donor liver transplantation using the right lobe. Methods Seventy-four donors and recipients were included in this study. Intraoperative Doppler ultrasound (IOUS)were performed before splitting the donor liver and 1 hour after the graft reperfusion. The diameter and velocity of portal vein were measured and recorded for calculation of portal vein flow(PVF). Liver function tests were undertaken at the day 2nd,7th, 15th and 30th postoperative,respectively. Results One hour after reperfusion of 74 grafts,the PVF were significantly increased (2. 84 ± 0. 93) fold. Seventy-four grafts were divided into 4 groups according to the different degrees of the increase of PVF. The levels of blood bilirubin total(TBIL) among 4 groups were differently at the day 2nd,7th, 15th and 30th postoperative. High PVF contributed to recipient's prolonged hyperbilirubinemia ( P <0. 001 ). The levels of ALT, AST among 4 groups were differently at the day 7th, 15th and 30th postoperative( P <0. 001). Conclusions Detection of portal vein hemodynamics in living donor liver transplantation by IOUS may assist surgeon to anticipate the graft's function and take surgical therapies to secure the graft and the recipient.
2.Research on the method of calibrating infusion pump
Hui TANG ; Hongtao SHANG ; Yanchun JIAO
China Medical Equipment 2013;(11):54-55
Objective:The infusion pumps are high risk equipment in clinic, the clinical risk of it is much higher the general medical equipment and diagnostic. Methods:FLUKE lagu1 was used to calibrate the Smiths infusion pumps in different conditions. Results: As a result, the quality control of it is particularly important. We introduce a method to calibrate model 1200 infusion pump from the angle of quality control. Conclusion: Infusion pump quality control testing should accord with clinical practice. Infusion pumps calibrated to provide security for the clinical infusion therapy and reduce the medical risk.
3.Histopathological observations on mice experimentally infected with plerocercoid
Hongtao JIANG ; Yan CHENG ; Guiwen TANG
Chinese Journal of Zoonoses 2010;(3):226-228
To observe the histopathological changes of mice experimentally infected with plerocercoid,mice were infected orally by plerocercoids that were collected from Rana nigromaculatus (5 strips/mouse),and were killed 2-10 weeks later to undergo the histopathological observation.Plerocercoids were found in the skin,muscle,liver,lung cavity of mice.There were diffuse congested spots and capsule formation ;the fat tissue showed severe degeneration and necrosis.In the fibrous tissues ,moderate proliferation of the enveloping adipose tissue was demonstrated.In addition,a large number of acute and chronic inflammatory cell infiltration and abscess formation could be found.It is evident that the plerocercoids parasitize mainly in the subcutaneous tissues and muscles of mice.and mice experimentally infected with plerocercoids show different degree of histopathological changes.
4.Preliminary Study of Medical Device Adverse Events
Hui TANG ; Hongtao SHANG ; Wen LIU
Chinese Medical Equipment Journal 2004;0(08):-
Medical devices are widely used in the treatment of diseases,health care and rehabilitation process as modern science and technology products,and become an important means in the field of modern medicine. How to ensure that medical devices are used safe and effective is the common problem in production,management,use and monitoring.
5.Effects of cyclooxygenase-2 inhibitor celecoxib on the phenotypes and function of glioma dendritic cells
Hongtao ZHANG ; Chunming XIU ; Hongquan NIU ; Yunbo WANG ; Guotai TANG
Chinese Journal of Behavioral Medicine and Brain Science 2012;21(10):880-883
ObjectiveTo investigate the effects of glioma microenvironment and COX-2 inhibitor celecoxib on the phenotypes and function of dendritic cell (DC).MethodsThe expression of cyclooxygenase-2 (COX-2) and prostaglandin E2 (PGE2) production were detected in glioma C6 cells treated with different concentration of celecoxib.Monocytes were isolated from human peripheral blood and cultured with 200 ng/ml rhGM-CSF and 50 ng/ml rhIL-4,either C6 tumor cells supernatant (TSN) or TSN from C6 cells treated with celecoxib to generate DCs.Cell morphology was observed.Cell phenotype including CD1a,CD80,CD83 and D86 were analyzed on a FACScan.Production of IL-12 in DC supernatant and the potential to stmiulate allogeneic T cell proliferation were detected.ResultsThe expression of COX-2 and PGE2 production in C6 cells decreased after treated with celecoxib in a concentration dependant manner.Typical DCs were induced in all groups and the expression of CD1a ((75.56±2.40)%,(75.09±3.67)%,(76.03 ±3.43)%),CD83((72.04±3.45)%,(71.44±3.78)%,( 73.63 ± 3.31 ) % ) had no difference (P > 0.05 ).Expression of CD80 ( ( 58.41 ± 3.85 ) % ),CD86 ( ( 58.22 ±3.25)% ) in DC with TSN obviously decreased compared with normal group( (70.36 ± 2.91 )%,(69.31 ±4.29 ) %,P < 0.01 ) as well as the IL-12 production ( ( 137.88 ± 5.33 ) pg/ml,( 186.04 ± 4.76 ) pg/ml) and the potential to stmiulate allogeneic T cell proliferation ( P < 0.01 ).Celecoxib increased the expression of CD80,CD86 (66.83 ± 2.51,63.51 ± 5.47,P< 0.01 ) in DC and the same as IL-12 production( ( 170.31 ± 3.46) pg/ml,P < 0.01 ) and the potential to stmiulate allogeneic T cell proliferation ( P < 0.01 ),which were lower than the normal level.ConclusionGlioma microenvironment may induce the celecoxib can inhibit the expression of COX-2 and PGE2 in gliomas cells and improve the phenotypes and function defect of DCs.
6.Clinical analysis of cerebellar infarction with vertebral artery hypoplasia
Shu TANG ; Zhigang MA ; Qin LIAO ; Yuheng SUN ; Hongtao HU
Chinese Journal of Postgraduates of Medicine 2016;39(9):783-786
Objective To summarize the clinical features and vascular lesions in patients who suffered from cerebellar infarction with vertebral artery hypoplasia(VAH). Methods Retrospective analysis was used in the research. The selected patients suffered from cerebellar infarction with VAH or stenosis (stenosis rate≥50%). Seventy-one patients with cerebellar infarction were enrolled. There were 34 patients in VAH group and 37 patients in vertebral artery stenosis group. The age, sex, risk factors, clinical manifestations and characteristics of vascular examination were compared. Results The age, sex, risk factors between two groups had no significant differences (P>0.05). The scores of National Institutes of Health Stroke Scale (NIHSS) between two groups had no significant difference (P>0.05). The proportion of early neurological deterioration in VAH group (41.2%, 14/34) was higher than that in vertebral artery stenosis group (18.9%, 7/37), χ2=4.21, P<0.05. There were more patients with anterior circulation artery stenosis in the VAH group (35.3%, 12/34), compared with that in artery stenosis group (13.5%, 5/37),χ2=4.62, P<0.05. Except the ipsilateral vertebral artery, other arteries stenosis in VAH group (44.1%, 15/34) was significantly higher than that in vertebral artery stenosis group (13.5%, 5/37),χ2=8.20, P<0.05. Conclusions Cerebellar infarction with vertebral artery hypoplasia is more likely to have multiple cerebral arterial stenosis (stenosis rate ≥50%). The patients who suffered from cerebellar infarction with vertebral artery hypoplasia might be prone to early neurological deterioration.
7.Value of contrast-enhanced ultrasound in diagnosis of postoperative complications after pancreas transplantation
Hongtao WU ; Ying TANG ; Jingwen ZHAO ; Ningning NIU ; Yang LIU
Chinese Journal of Ultrasonography 2015;24(3):237-241
Objective To investigate the clinical value of contrast-enhanced ultrasound (CEUS) in the diagnosis of postoperative complications after pancreas transplantation.Methods Eighty-six post pancreastransplantation patients were examined by CEUS to observe the perfusion of contrast agent,plot timeintensity curve (TIC),and compare to the results of enhanced CT,MRI and pathology.Results Eleven cases of thrombosis,13 cases of rejection and 13 cases of pancreatitis were observed among 86 patients.Result from CEUS showed that:① Distribution of normal pancreatic grafts vascular and parenchyma was even,TIC follows positive skewed distribution.②Thrombosis:there was no perfusion in the embolic vessels and no enhancement or low uneven enhancement in the parenchyma.③ Rejection:perfusion of the parenchyma was slow,peak value was decreased,rising and falling slope of the TIC was reduced with blunt peak.④Pancreatitis:perfusion of the parenchyma was uneven,the regional low enhanced area was visible,clear of the contrast agent was relatively slow,rising slope of TIC was reduced and the peak value was decreased.Conclusions CEUS can monitor the perfusion of the pancreatic grafts vascular and parenchyma,and get useful perfusion parameters.It has been proven as an effective method to definitely diagnose postoperative complications after pancreas transplantation.
8.Relationship between the quantitative analysis of tissue diffusion and the level of serum creatinine in chronic renal allograft injury
Ningning NIU ; Ying TANG ; Hongtao WU ; Yang LIU ; Jing LIU
Chinese Journal of Ultrasonography 2014;23(10):875-878
Objective To investigate the quantitative analysis of tissue diffusion of real-time elastography(RTE) in chronic renal allograft injury(CRAI) and the relationship between RTE and the level of serum creatinine(Cr).Methods Sixty-nine cases of allograft renal transplantation patients were detected by conventional ultrasound and RTE.According to the time after operation and Cr,they were divided into three groups:group A (in three months after operation and normal Cr,25 cases),group B (more than three months after operation and normal Cr,23 cases),and group C (more than three months after operation and high Cr,21 cases).The results were compared and analyzed.Results ①Contrast between group A and group B,there were differences on Cr and average ralative strain value(MEAN),area ratio of low-strain region (% AREA),complexity (COMP),skewness (SKEW),(P < 0.05).② In group B,there was correlation between Cr and %AREA,MEAN,SKEW (r =0.682,P <0.05; r =0.628,P <0.05; r =-0.481,P <0.05).③To make ROC curve,MEAN has higher sensitivity (90.9%),COMP has higher specificity and accuracy (68.0%,81.8%).④ To apply the third result in group C,4 or 5 cases in 21 were abnormal.Conclusions There is a good correlation between the quantitative analysis of tissue diffusion and the level of serum creatinine.RTE can indirectly reflect CRAI,and it is a new method of ultrasonic to evaluate renal allograft function.
9.Repairation of bone and skin defect in leg with vascularized tibial bone-skin flap graft
Hongtao TANG ; Caining LI ; Chong WANG ; Zhenzhen CHENG ; Chunsheng CHENG
Chinese Journal of Microsurgery 2015;38(5):428-431
Objective To explore the outcome of the tibial bone-skin flap grafts in the management of severe traumatic osteomyelitis complicated with bone and skin defect in leg.Methods Twenty-seven cases of the traumatic osteomyelitis complicated with bone and skin defect in leg were treated with vascularized tibial bone-skin flap grafe from August, 2007 to November, 2013.Reconstruction of limb tibia continuity and cover the wound.Results The tibial bone-skin flaps were completely survived in 26 of the 27 cases except 1 ease which was repaired by adjacent flap because of the disorder blood circulation.The followed-up showed that all flaps had good blood circulation.The infection was controlled completely.The leg function and contour were satisfactory.Conclusion The tibial boneskin flap has the advantages of abundant blood supply, full bone-skin flap supply, shortens hospitalization and suitable for treatment of traumatic osteomyelitis complicated with bone and skin defect in leg.
10.Evaluation of acute rejection after liver transplantation with acoustic radiation force impulse and color Doppler flow imaging
Ying TANG ; Jingwen ZHAO ; Hongtao WU ; Jing LIU ; Yang LIU
Chinese Journal of Ultrasonography 2015;(7):589-591,592
Objective To investigate the value of acoustic radiation force impulse (ARFI)and color Doppler flow imaging (CDFI)in the diagnostic of acute rejection (AR)after liver transplantation.Methods B mode ultrasound,CDFI and ARFI exams were performed on fifty-eight patients who was diagnosed with AR through liver biopsy in our hospital.The liver allograft size,mean velocity of portal vein,hepatic vein spectrum waveform and shear-wave velocity were obtained and compared with the results of 30 healthy subjects as control group.Results Compare to control group,the AR group had a significant increase in liver allograft,decrease in mean velocity of portal vein,the elimination of triphasic wave of hepatic vein,and a significant increase in shear-wave velocity (P =0.000,0.000,0.007,0.000,respectively).The correlation coefficient between four criteria and grouping was 0.478,0.557,0.286,0.483,respectively.The area under ROC curves for diagnosing AR using the four criterias mentioned above was 0.914.Conclusions Combination of CDFI and ARFI in diagnosing of AR after liver transplantation has higher sensitivity and accuracy.