1.Observation on the Ultrastructure of Liver Cells around Hydatid Cyst
Shijie ZHANG ; You LV ; Hong SUN ; Hongqiang YANG ; Xinyu PENG
Chinese Journal of Parasitology and Parasitic Diseases 1997;0(05):-
Liver tissues around hydatid from 8 patients with cystic echinococcosis were observed by transmission electron microscopy,normal hepatic tissues of 6 cases were used as control.The results demonstrated predominant atrophy and necrosis of hepatocytes.These changes seem to be the major hepatic lesion in cystic echinococcosis.
2.Dosimetric comparison of combined intracavitary/interstitial brachytherapy planning using three different kinds of optimization methods in locally advanced cervical cancer
Kaiqiang CHEN ; Hongqiang YOU ; Qixin LI ; Xiaolei NI ; Wenjuan CHEN ; Xiuchun ZHANG ; Penggang BAI ; Ye CAO ; Jihong CHEN
Chinese Journal of Radiological Medicine and Protection 2018;38(3):215-219
Objective To compare and analyze the dosimetric discrepancy of combind intracavitary/interstitial brachytherapy using three different kinds of optimization method in locally advanced cervical cancer.Methods Totally 20 cases of locally advanced cervical cancer were selected and divided into three groups according to different optimization method which include manual optimization group (MO) based on graphical optimization,inverse planning simulated annealing (IPSA 1)based on simulated annealing optimization algorithm,IPSA 2 based on IPSA 1 with limitation on maximum dose of target.The dose volume histogram parameters of the targets (V200,V150,V100,D100,D90,HI) and the OARs(D0.1 cm3,D1 cm3 and D2 cm3) were analyzed.Results For CTV,compared with MO,there was no significantly statistical difference in D100between IPSA 1 and IPSA 2(P > 0.05).However,V200,V150,V100 and HI for ISPA1 were better than for ISPA2 (t =-3.422-9.910,P < 0.05).In addition,V100 and D100 in ISPA1 were better than in ISPA2 (t =7.238,5.032,P <0.05).For OARs,D0.1 cm3,D1 cm3 and D2 cm3 in rectum,bladder,sigmoid colon of both ISPA 1 and ISPA 2 were dramatically lower than those of MO (t =2.235 5.819,P < 0.05),without significantly statistical difference found between ISPA1 and ISPA2.Conclusions For combined intracavitary/interstitial brachytherapy in locally advanced cervical cancer,all treatment plans based on three different kinds of optimization methods can meet the clinical need.Moreover,inverse optimization can ensure dose coverage over target and reduce maximum dose of rectum,bladder and sigmoid colon.
3.The dosimetric effect of random six-dimensional setup error in intensity-modulated radiotherapy planning for rectal cancer
Jiajun ZHENG ; Hongqiang YOU ; Geng XU ; Zhenyu ZHAI ; Xia HE ; Li SUN
Chinese Journal of Radiological Medicine and Protection 2023;43(11):881-887
Objective:To design a method to introduce random six-dimensional setup error (6D-SE) into the intensity-modulated radiotherapy (IMRT) planning for rectal cancer and evaluate its dosimetric effect.Methods:A total of 21 IMRT plans for patients with rectal cancer were randomly selected as reference plans [2 Gy per fraction for a total of 50 Gy; a 5 mm uniform margin around the clinical target volume (CTV) was taken as the planning target volume (PTV)]. For each fraction of the reference plan, a randomly generated 6D-SE was introduced by adjusting the geometrical parameters of the radiation field, and the dose was recalculated. The overall dose distribution with 6D-SE was obtained by adding up the dose of each fraction. A treatment simulation program that could complete the above workflow was developed using the Varian Eclipse scripting API (ESAPI). 6D-SEs that obey two preset distributions [distribution 1: translational error obey N(0, 4 2), and rotational error obey N(0, 2 2); distribution 2: translational error obey N(0, 2 2), and rotational error obey N(0, 1 2)] were introduced into the reference plans, and the dosimetric effects were assessed. Results:When the reference plans, error distribution 1, and error distribution 2 were applied, the Dmin values of the CTV were (49.4±0.41), (47.56±0.76), and (49.17±0.64) Gy, respectively; the D98% values of the CTV were (50.23±0.07), (49.98±0.10), and (50.27±0.09) Gy, respectively; the D98% values of the primary target area (the kernel part of the target area, excluding the margins) were (50.25±0.08), (50.42±0.13), and (50.33±0.10) Gy, respectively; the D98% values of the marginal area were (50.22±0.10), (49.88±0.11), and (50.26±0.10) Gy, respectively. In addition, compared with the result of the reference plans, the result of errors 1 and 2 showed no significant changes in the mean dose of the bladder and femoral heads ( P>0.05), despite slight decreases in the conformity index of the dose distribution with limited clinical significance. Conclusion:The proposed method and the treatment simulation program developed thereupon can introduce the 6D-SE obeying different distributions into the IMRT plans for rectal cancer on demand and provide overall dosimetric changes.
4. Study on the improvement of Qingdaipowder Gel for external use on mice with specific dermatitis
Yurong HUANG ; Yan WANG ; Jie FAN ; Yingli WANG ; Ying JIA ; Hongqiang ZHANG ; Rongli YOU
Chinese Journal of Clinical Pharmacology and Therapeutics 2023;28(1):19-28
AIM: To study the effect of Qingdaipowder Gel (QDPG) on mice specific dermatitis (AD) model and the antibacterial effect of the ethanol extract of Qingdaipowder. METHODS: AD model of mice was established by repeated skin induction with 2,4-dinitrochlorobenzene (DNCB). Fifty-six mice were randomly divided into blank group, model group, Hydrocortisone Butyrate Cream group (Hyd, 1.5 mg/cm