1.Induction mechanism and research progress of CYP2C9
Chinese Pharmacological Bulletin 2003;0(09):-
CYP2C9 is an important enzyme of drug metabolism expressed in liver, It can metabolize several clinically important drugs, some with a low therapeutic index. This review summarizes the CYP2C9 gene structure, induction mechanism, known polymorphism and functional significances and their population frequencies.
2.Alternative splicing of gene transcription and its progress in clinical pharmacology
Chinese Pharmacological Bulletin 1986;0(06):-
Alternative splicing is strictly affected by special cell or tissue and the stage of development so that it plays a vital role in development, cell or tissue differentiation and their function, accordingly, abnormal splicing will cause the functional disorder of body, and heritable diseases. Currently, the investigation on regulation of alternative splicing and its mechanism, function of its products and how to apply it into clinical practices is one of the extremely important area of pharmacogenomics
3.Types of ulnar styloid process fracture and treatment of distal radius fracture
Youting DANG ; Honghao DUAN ; Fei XIE ; Qiang WANG ; Yunping ZHOU ; Dengke WEI ; Xuehai OU
Chinese Journal of Orthopaedic Trauma 2022;24(2):168-172
Objective:To investigate the effects of types of ulnar styloid process fracture on the treatment of distal radius fracture.Methods:The 80 patients were analyzed retrospectively who had been treated at The First Department of Hand Surgery, Honghui Hospital from January 2019 to January 2020 for fracture of distal radius complicated with fracture of ulnar styloid process. They were 25 males and 55 females, aged from 30 to 85 years (average, 58.6 years). According to the types of ulnar styloid process fracture, 40 patients were assigned into a Hauck type Ⅰ group and the other 40 into a Hauck type Ⅱ group. The 2 groups were compared in terms of operation, postoperative complications, hospital stay, bone union, visual analogue scale (VAS) on postoperative 1 to 3 days, and modified Mayo wrist function score, wrist range of motion and quality of life by WHOQOL-BREF at the last follow-up.Results:The 2 groups were comparable because there was no significant difference in age, gender, American Society of Anesthesiologists (ASA) rating, or time from injury to operation between them ( P>0.05). All the patients were followed up for 12 to 24 months (average, 17 months). There was no significant difference between Hauck type Ⅰ group and Hauck type Ⅱ group in operation time, intraoperative blood loss, hospital stay, rate of postoperative complications, fracture union, modified Mayo wrist function score or VAS on postoperative 1 to 3 days ( P>0.05). At the last follow-up, the palm tilt and ulnar inclination angles were 13.8°±1.9° and 21.6°±2.8° in Hauck type Ⅰ group, significantly larger than those in Hauck type Ⅱ group (11.9°±1.6° and 18.8°±2.3°) ( P<0.05). At the last follow-up, Hauck Ⅰ group scored 85.3±6.4,85.6±6.5, 84.7±6.3 and 85.0±6.7 respectively in the domains of physical health, psychology, environment and social relationships, significantly higher than those Hauck type Ⅱ group did (78.5±6.5, 78.9±6.5, 77.8±6.1 and 77.9±6.3) ( P<0.05). Conclusions:In open reduction and internal fixation for distal radius fracture, Hauck Type Ⅰ fracture of ulnar styloid process has no significant effect on the functional recovery of the wrist but Hauck Type Ⅱ fracture of ulnar styloid process may. Therefore, surgical fixation needs to be strengthened if Hauck Type Ⅱ fracture of ulnar styloid process is complicated.
4.Portable Pulse Detection System Based on IoT.
Qijun DAI ; Yuping ZHAO ; Qianqian WANG ; Tao LYU ; Yulin SUN ; Hufei DUAN ; Meili LIU ; Jinna YANG ; Honghao WANG
Chinese Journal of Medical Instrumentation 2021;45(2):125-130
Aiming at the current situation of high cost, huge volume, complex operation and difficulty in real application of pulse analyzer, this study designs and implements a portable pulse detection system based on IoT. The design utilizes Raspberry Pi 3B+, STM32 series MCU and cloud server to collect, store, display and recognize pulse signals at CUN, GUAN and CHI. The system is small in size and low in cost, which can be connected with cloud server through network to make full use of resources. The experimental results show that the recognition accuracy of the main feature points of the pulse signal by the portable pulse analyzer is higher than 97%, which has a broad prospect of development and application.
Computers
;
Heart Rate