1.Expression of chemokine-like factor 2 (CKLF?2) mRNA in rat myocardium at different development phase
Hongkun REN ; Tao HONG ; Jie JIANG
Chinese Journal of Interventional Cardiology 1993;0(03):-
Objective To investigate the expression of CKLF?2 mRNA in rats′ myocardium at different development phase. Methods Total RNA was extracted from fetal rat hearts at day12 and day 18 after coitus, and from new-born rat hearts right after birth, day 3, day 7 and day 21 after birth, as well as from adult rat hearts. The expression of CKLF?2 mRNA was tested by competitive polymerase chain reaction (CPCR). Results Compared with the postnatal myocardium, the expression of CKLF?2 mRNA obtained its peak level in the 12-day-post coitus, which then decreased gradually to a relatively low level until birth. It increased slightly at birth and subsided to the lowest level in adulthood. Conclusion CKLF?2 probably takes part in the procession of the myocardial proliferation and the development of rat′s heart.
2.Effects of low-frequency ultrasound combined with Tongluo Zhitong herbs on urokinase-type plasminogen activator system and inflammatory cytokines in knee osteoarthritis
Hong ZHANG ; Dongsheng REN ; Yafei TAO
Chinese Journal of Tissue Engineering Research 2017;21(8):1149-1154
BACKGROUND: Low-frequency ultrasound combined with Tongluo Zhitong herbs can effectively relieve pain and improve joint function of patients with osteoarthritis, but the underlying mechanisms are still unclear.OBJECTIVE: To investigate the effects of low-frequency ultrasound combined with Tongluo Zhitong herbs on urokinase-type plasminogen activator (uPA) and inflammatory cytokines of osteoarthritis rabbits and the related mechanisms.METHODS: Forty rabbits were randomly divided into four groups: normal, model, control, and experimental groups. The normal group was treated with normal feeding, not for any processing. For the other three groups, papain was injected into the rabbit knee articular cavity to establish osteoarthritis models. One week later, the experimental group was treated with low frequency ultrasound combined with Tongluo Zhitong herbs for 3 weeks, the control group treated with the same volume of normal saline, and the model group received no intervention. The levels of inflammatory cytokines in the serum and synovial fluid were measured, the histological changes of synovial tissues and articular cartilage were evaluated using Mankin's score, and the expression levels of uPA and its receptor were determined by western blot assay.RESULTS AND CONCLUSION: The levels of inflammatory cytokines in the model group were significantly higher than those in the normal and experimental groups (P < 0.05). The Mankin's scores of synovial tissue in the experimental group were significantly lower than those in the model and control groups (P < 0.05), while Mankin's scores of the cartilage tissue had no significant difference between the experimental and model groups (P > 0.05). Compared with the model group, in the experimental group, the expression levels of uPA and its receptor were significantly downregulated,and the expression of uPA inhibitor was notably upregulated. These data show that low-frequency ultrasound combined with Tongluo Zhitong herbs attenuates inflammatory reaction in the synovial tissues, by inhibiting the formation of joint fluid and production of inflammatory cytokines, which is an effective treatment for knee osteoarthritis.
3.Biological features of ultrasound assisted acellular spinal cord scaffold
Hong YIN ; Xianjun REN ; Tao JIANG ; Changli ZHOU ; Kaijian WANG
Chinese Journal of Trauma 2013;(3):278-283
Objective To observe three-dimensional structure and biological features of rat acellular spinal cord scaffold prepared by sonic oscillation and chemical extraction in order to offer an ideal scaffold for spinal cord tissue engineering research.Methods Rat spinal cord underwent acellular treatment with sonic oscillation and chemical extraction (Triton X-100 at volume fracture of 2% and sodium deoxycholate at volume fracture of 2%) (acellular spinal cord group).In contrast with spinal cord tissue of normal rats (control group),general morphology,histology and ultramicro three-dimensional structure of acellular spinal cord scaffold were observed and aperture size,factor of porosity,water ratio,enzymolysis ratio and stability in water solution of the scaffold were also detected.Results Acellular spinal cord group showed effective removal of original cell components with factor of porosity for (94.57 ±3.45) % and water content for (88.62 ± 1.0) %,and satisfactory three-dimensional structure with average aperture of 46 μm.Scaffold showed gradual degradation in enzymolysis solution and enzymolysis rate reached (69.03 ± 2.19)% at 20 hours.Besides,scaffold showed stepwise disintegration in double distilled water and hydrolysis rate was (62.55 ± 1.70) % at 8 days.While,normal spinal cord showed close structure,generous neurons and myelin sheath with factor of porosity for (0.04 ± 0.02) % and water content for (62.4 ± 1.5) %,and unobvious pore structure under scanning electron microscope.Normal spinal cord were degraded gradually in enzymolysis solution and enzymolysis rate was (37.62 ± 0.9)% at 20hours.In the meantime,normal spinal cord were disintegrated gradually in double distilled water and hydrolysis rate was (40.97 ± 0.81) % at 8 days.Conclusions Acellular spinal cord scaffold prepared by sonic oscillation plus chemical extraction achieves complete removal of cell components,intact extracellular matrix,and satisfactory results in three-dimensional network structures,factor of porosity and water content.Also,the scaffold meets theoretical demands of tissue-engineered spinal cord scaffold and is an ideal alterative for tissue-engineered spinal cord scaffold.
5.Analysis of 130 forensic expertise cases of simple orbital fracture.
Wei HUANG ; Cheng-Ren ZHU ; Hong HUANG ; Mei-Shui TAO
Journal of Forensic Medicine 2014;30(5):357-359
OBJECTIVE:
To analyze the features of orbital fracture and to discuss its forensic expertise points.
METHODS:
One hundred and thirty cases of simple orbital fracture from 2010 to 2012 collected from one public security bureau were retrospectively analyzed such as age, gender, tools, position and morphology of the fracture, periorbital and orbital compound injury and the follow-up results after 6 months.
RESULTS:
In the 130 cases, the wounded were mainly young men and hit by fist. The fracture of simple medial orbital wall accounted for up to 81.5% in all cases. In the periorbital and orbital compound injury, laceration and contusion of eyelid and ethmoidal cellules and maxillary sinus always occurred. After 6 months follow-up, there were 30 cases of comminuted fracture remained enophthalmos compared with the uninjured side.
CONCLUSION
It is inappropriate to judge the fracture of simple medial orbital wall as minor injury. We should judge the degree of simple orbital fracture after the injury is stable. Detailed ophthalmology inspection is necessary for forensic expertise of simple orbital fracture.
Craniocerebral Trauma
;
Enophthalmos
;
Female
;
Fractures, Comminuted/pathology*
;
Humans
;
Male
;
Ophthalmologic Surgical Procedures
;
Orbit
;
Orbital Fractures/surgery*
;
Retrospective Studies
;
Severity of Illness Index
;
Trauma Severity Indices
6.Applications of the hospital statistics management system.
Hong ZHAI ; Yong REN ; Jing LIU ; You-Zhang LI ; Xiao-Long MA ; Tao-Tao JIAO
Chinese Journal of Medical Instrumentation 2008;32(1):64-69
The Hospital Statistics Management System is built on an Office Automation Platform of Shandong provincial hospital system. Its workflow, role and popedom technologies are used to standardize and optimize the management program of statistics in the total quality control of hospital statistics. The system's applications have combined the office automation platform with the statistics management in a hospital and this provides a practical example of a modern hospital statistics management model.
Hospital Administration
;
Hospital Information Systems
;
Office Automation
;
Statistics as Topic
7.Expression of tear fluid IL-6 in patients with diabetic retinopathy at different phase and its relationship with blood HbA1c in Shijiazhuang urban communities′ elderly people
Weichao WANG ; Jie ZHANG ; Hong WANG ; Subo LIU ; Xin WANG ; Tao WU ; Yi LIANG ; Qiaohua REN
The Journal of Practical Medicine 2015;(18):3084-3087
Objective To investigate the relationship between HbA1c in blood and IL-6 in tear fluid of the elderly patients with diabetic retinopathy ( DR ) in Shijiazhuang urban communities , and the relationship between IL-6 in tear fluid and the severity of DR. Methods The elderly people who lived more than 5 years , older than ≥45 year old. in nine urban communities of Shijiazhuang were stratified randomly sampled and received cross-sectional epidemiology questionnaire survey and OGTT. A total of 1 447 subjects (509 males and 938 females) were included. Each participant underwent epidemiological surveys and oral glucose tolerance test (OGTT), according to the 1999 WHO diabetes mellitus (DM) diagnostic criteria established. For patients who were newly or previously diagnosed as DM. HbA1c level, tear fluid IL-6 and serum IL-6 tested.The severity of DR was evaluated by fundus examination, the people were divided into normal group(NGT), non-diabetic retinopathy ( NDR ) , non-proliferative diabetic retinopathy ( NPDR ) , and proliferative diabetic retinopathy ( PDR ) . The correlation of serum IL-6 and tear fluid IL-6,blood HbA1c and tear fluid IL-6 were assessed by SPSS 19.0 statistical software. Results Concentrations of tear fluid IL-6 were (3.10 ± 1.25)pg/mL in the NGT group, (10.25 ± 3.22)pg/mL in the NDR group,(16.80 ± 5.76)pg/mL in the NPDR group,(25.11 ± 5.20)pg/mL in the PDR group(P < 0.01). SNK-q test revealed significant differences between every two groups (P < 0.01,P <0.05,P < 0.05) Concentrations of serum IL-6 were (88.04 ± 17.06)pg/mL in the NGT group,(126.38 ± 20.73) pg/mL in the NDR group, (239.83 ± 40.33)pg/mL in the NPDR group, (268.36 ± 27.72)pg/mL in the PDR group(P < 0.01). SNK-q test revealed significant differences between every two groups (P < 0.01). Tear fluid IL-6 level was positively correlated with serum IL-6 level(R = 0.756,P < 0.01). Tear fluid IL-6 level was positively correlated with blood IL-6 level (R = 0.338, P < 0.01). Conclusion The tear fluid IL-6 levels of the elderly patients with DM in Shijiazhuang urban communities , increased; with the increased severity of DR , the levels of tear fluid IL-6 gradually increase. The level of tear fluid IL-6, serum IL-6, HbA1c closely correlates with the severity of DR.
8.Preparation and biomechanical property of genipin-crosslinked rat acellular spinal cord scaffolds
Tao JIANG ; Xianjun REN ; Hong YIN ; Kaijian WANG ; Changli ZHOU ; Yongyang TIAN
Chinese Journal of Trauma 2014;30(2):180-184
Objective To construct genipin-crosslinked rat acellular spinal cord scaffolds and evaluate their enzymatic degradation rate,biomechanical properties and cytotoxicity.Methods Rat spinal cord scaffolds were decellularized by chemical extraction and chemically crosslinked with 5 g/L genipin solution.Micro-structure of the uncrosslinked and genipin-crosslinked acellular spinal cord scaffolds were observed by HE staining and scanning electron microscopy and properties of pore size,porosity,water ratio,and degradation rate in 2.5 g/L trypsin enzyme solution were examined.Ultimate tensile strength and elastic modulus of normal rat thoracic spinal cord,uncrosslinked and genipin-crosslinked acellular spinal cord scaffolds were determined on Instron mechanical testing instrument.Rat bone marrow mesenchymal stem cells were cultured in lixivium of uncrosslinked and genipin-crosslinked acellular spinal cord scaffolds and MTT assay for relative cell growth rate was test to evaluate the cytotoxicity of scaffolds.Results The uncrosslinked and the genipin-crosslinked acellular spinal cord scaffolds possessed a similar three-dimensional mesh-porous structure with a mean pore diameter about 30 μm and a porosity over 80%,but there was a statistical difference between the two groups(P > 0.05).Water ratio of genipincrosslinked scaffolds was (229.7 ± 12.5) %,far lower than (283.4 ± 11.2) % of uncrosslinked scaffolds (P < O.05) ; genipin-crosslinked acellular spinal cord scaffolds had lower weight loss at each time point than the uncrosslinked acellular spinal cord scaffolds (P < 0.05),but the stability in trypsin,ultimate tensile strength and elastic modulus of acellular spinal cord scaffolds were significantly enhanced by genipin-crosslinking (P < 0.05).Furthermore,no obvious cytotoxicity was observed in the uncroslinked and genipin-crosslinked scaffolds.Conclusions Rat acellular spinal cord scaffolds present no obvious change in structure after genipin-crosslinking,but there is significant improvement in the biomechanical properties and ability against enzymatic degradation and no marked cytotoxicity.Hence,the genipincrosslinked scaffolds are promising in tissue engineering for spinal injury.
9.Study on the accuracy of thoracolumbar pedicle screw installation assisted by O-arm navigation
Tao JIANG ; Xianjun REN ; Weidong WANG ; Tongwei CHU ; Changqing LI ; Hong YIN ; Zegang SHI
Chinese Journal of Trauma 2015;31(7):614-618
Objective To evaluate the accuracy and reliability of O-arm-based thoracolumbar pedicle screw installation.Methods A retrospective review was conducted on 75 patients who had undergone thoracolumbar pedicle screw fixation assisted with O-arm navigation (navigation group,n =32) and C-arm fluoroscopy (fluoroscopy group,n =43) from March to October 2014.All the patients were assessed with X-ray and CT images after operation.Accuracy of screw installation in both groups was compared.In navigation group,screw directions were measured on the sagittal and axial images of intraoperative navigation and post-operative CT scanning to evaluate the concordance.Results In fluoroscopy group,a total of 206 pedicle screws were placed with the one-time success rate of 93.2% and accuracy of 90.8% for screw placement,and one misplaced screw (grade llⅢ) led to L3 nerve root symptom.In navigation group,a total of 226 pedicle screws were placed with the one-time success rate of 100% and accuracy of 96.9% for screw placement,and no screw was grade Ⅲ.Further,there were no significant differences in screw directions on the sagittal and axial images between intraoperative navigation and postoperative CT scanning (P > 0.05).Conclusion O-arm navigation that provides high-resolution images and high precision improves the accuracy of thoracolumbar pedicle screw installation,and possesses good reliability.
10.Identification of andrographolide hydroxypropyl-?-cyciodextrin inclusion compound and study on its thermodynamic stability
Ke REN ; Zhi-Rong ZHANG ; Jing-Hong JU ; Yang LIU ; Tao GONG ;
Chinese Traditional and Herbal Drugs 1994;0(04):-
Objective To prepare and identify the andrographolide-hydroxypropyl-?-cyclodextrin(an- drographolide-HP-?-CD)inclusion compound.The tool ratio between andrographolide and HP-?-CD and the thermodynamic constants in inclusion were studied simultaneously.Methods The andrographolide- HP-?-CD inclusion compound was prepared with lyophilization technique.Meanwhile,the inclusion com- pound was identified by differential scanning calorimetry(DSC)methods,infrared spectrometry(IR),and X-ray diffraction(XRD),respectively.The tool ratio between host and guest moleculars and the thermo- dynamic constants during the inclusion process were also researched by phase solubility method.Results An 1:1 molar ratio inclusion complex of andrographolide with HP-?-CD could be formed at 25,35,and 45 C.The phase diagram was A_L type and the procedure of inclusion was a heat release process.Conclusion The solubility of andrographolide-HP-?-CD inclusion compound can be increased obviously by the above- mentioned preparing techniques.